Skip to main content
Erschienen in: International Orthopaedics 10/2017

29.03.2017 | Original Paper

Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series

verfasst von: James C. Shaw, Milton L. “Chip” Routt Jr., Joshua L. Gary

Erschienen in: International Orthopaedics | Ausgabe 10/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Traditional fluoroscopic techniques during percutaneous fixation of the posterior pelvic ring at times cannot adequately visualize errant or malpositioned iliosacral screws. Intra-operative fluoroscopic techniques have been advanced using multi-dimensional fluoroscopy to generate computed tomography-like images. This provides the surgeon not only the ability to assess iliosacral screw placement, but also the opportunity to assess reduction. We present a case series of four patients in which the Ziehm RFD multi-dimensional fluoroscopy was used to assess reduction and guidepin placement prior to definitive iliosacral screw fixation.

Methods

Four patients at our university level 1 trauma center with posterior pelvic ring disruptions were treated with percutaneous iliosacral screw fixation. Traditional fluoroscopic techniques were used during guidepin placement. Multi-dimensional fluoroscopy was performed using the Ziehm RFD 3D to assess guidepin placement and reduction prior to definitive iliosacral screw fixation.

Results

Our case series highlights two patients in which multi-dimensional fluoroscopy was utilized to ensure safe placement of iliosacral screws. In one of these two patients, a change was made after reviewing the imaging as a guidepin was found to be intruded into bilateral S2 neural tunnels. We also present two patient examples in which multidimensional fluoroscopy was used to assess reduction achieved by less invasive methods, precluding the need for direct visualization using more extensive open approaches.

Conclusions

This retrospective case series demonstrates the direct impact that the Ziehm RFD 3D technology provides in surgical management of patients with complex posterior pelvic ring injuries.
Literatur
1.
Zurück zum Zitat Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589CrossRefPubMed Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589CrossRefPubMed
3.
Zurück zum Zitat Herman A, Keener E, Dubose C, Lowe JA (2016) Simple mathematical model of sacroiliac screws safe-zone-easy to implement by pelvic inlet and outlet views. J Orthop Res. doi:10.1002/jor.23396 PubMed Herman A, Keener E, Dubose C, Lowe JA (2016) Simple mathematical model of sacroiliac screws safe-zone-easy to implement by pelvic inlet and outlet views. J Orthop Res. doi:10.​1002/​jor.​23396 PubMed
4.
7.
Zurück zum Zitat Zwingmann J, Hauschild O, Bode G, Sudkamp NP, Schmal H (2013) Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg 133(9):1257–1265. doi:10.1007/s00402-013-1788-4 CrossRefPubMed Zwingmann J, Hauschild O, Bode G, Sudkamp NP, Schmal H (2013) Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg 133(9):1257–1265. doi:10.​1007/​s00402-013-1788-4 CrossRefPubMed
11.
13.
Zurück zum Zitat Letournel E, Judet R (1993) Fractures of the acetabulum, 2nd edn. Springer, New YorkCrossRef Letournel E, Judet R (1993) Fractures of the acetabulum, 2nd edn. Springer, New YorkCrossRef
14.
Zurück zum Zitat Mears D, Rubash H (1983) Extensile exposure of the pelvis. Contemp Orthop 6(2):21–31 Mears D, Rubash H (1983) Extensile exposure of the pelvis. Contemp Orthop 6(2):21–31
15.
Zurück zum Zitat Reinert CM, Bosse M, Poka A, Schacherer T, Brumback R, Burgess A (1988) A modified extensile exposure for the treatment of complex or malunited acetabular fractures. J Bone Joint Surg Am 70(3):329–337CrossRefPubMed Reinert CM, Bosse M, Poka A, Schacherer T, Brumback R, Burgess A (1988) A modified extensile exposure for the treatment of complex or malunited acetabular fractures. J Bone Joint Surg Am 70(3):329–337CrossRefPubMed
Metadaten
Titel
Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series
verfasst von
James C. Shaw
Milton L. “Chip” Routt Jr.
Joshua L. Gary
Publikationsdatum
29.03.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 10/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3447-9

Weitere Artikel der Ausgabe 10/2017

International Orthopaedics 10/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.