Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 1/2014

01.01.2014 | Symposium: 2013 Knee Society Proceedings

Intraarticular Fibrinogen Does Not Reduce Blood Loss in TKA: A Randomized Clinical Trial

verfasst von: Thomas Jan Heyse, MD, Steven B. Haas, MD, Denise Drinkwater, BA, Stephen Lyman, PhD, Han Jo Kim, MD, Barbara A. Kahn, BS, Mark P. Figgie, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Bleeding remains an ongoing concern after total knee arthroplasty (TKA). Intraarticular application of human fibrinogen with a topical thrombin has been described to stop diffuse bleeding in knee arthroplasty.

Questions/purposes

It was hypothesized that the use of human fibrinogen as a topical agent would result in a reduction of bleeding and transfusions required after TKA; secondary end points included comparison of early clinical results including pain scores and range of motion (ROM) at 6 weeks and complications after surgery.

Methods

Two hundred patients undergoing TKA were randomized into a double-blind clinical trial to receive either intraarticular fibrinogen 2 minutes before tourniquet release or no such treatment. Postoperative hemoglobin and hematocrit levels, drain output, and transfusion requirements were recorded and blood loss was calculated. Clinical outcomes and adverse events were tracked prospectively. Descriptive analysis was performed using a two-sample t-test.

Results

There were no differences in calculated blood loss between the fibrinogen and the control groups; the mean postoperative drain output was 780 ± 378 mL in the fibrinogen group compared with 673 ± 301 mL in the control group (p = 0.029), but the hemoglobin drop at Day 2 was 3.47 ± 1.53 g/L in the fibrinogen group and 3.84 ± 1.24 g/Ll in the control group (p = 0.051). There were no differences in in transfusions, early ROM, visual analog pain scores, or complications between the groups.

Conclusions

The use of fibrinogen in TKA did not lead to a significant reduction of blood loss or transfusions in primary TKA for osteoarthritis. Given the lack of benefits and the costs this procedure adds to TKA, its routine use cannot be justified during primary TKA for osteoarthritis.

Level of Evidence

Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Alshryda S, Sarda P, Sukeik M, Nargol A, Blenkinsopp J, Mason JM. Tranexamic acid in total knee replacement: a systematic review and meta-analysis. J Bone Joint Surg Br. 2011;93:1577–1585.PubMedCrossRef Alshryda S, Sarda P, Sukeik M, Nargol A, Blenkinsopp J, Mason JM. Tranexamic acid in total knee replacement: a systematic review and meta-analysis. J Bone Joint Surg Br. 2011;93:1577–1585.PubMedCrossRef
2.
Zurück zum Zitat Bergel S. Über Wirkungen des Fibrins. Deutsche medizinische Wochenschrift. 1909;35:633CrossRef Bergel S. Über Wirkungen des Fibrins. Deutsche medizinische Wochenschrift. 1909;35:633CrossRef
3.
Zurück zum Zitat Birkmeyer JD, Goodnough LT, AuBuchon JP, Noordsij PG, Littenberg B. The cost-effectiveness of preoperative autologous blood donation for total hip and knee replacement. Transfusion. 1993;33:544–551.PubMedCrossRef Birkmeyer JD, Goodnough LT, AuBuchon JP, Noordsij PG, Littenberg B. The cost-effectiveness of preoperative autologous blood donation for total hip and knee replacement. Transfusion. 1993;33:544–551.PubMedCrossRef
4.
Zurück zum Zitat Charrois O, Kahwaji A, Vastel L, Rosencher N, Courpied JP. Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis. Int Orthop. 2001;25:22–24.PubMedCentralPubMedCrossRef Charrois O, Kahwaji A, Vastel L, Rosencher N, Courpied JP. Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis. Int Orthop. 2001;25:22–24.PubMedCentralPubMedCrossRef
5.
Zurück zum Zitat Cronkite EP, Lozner EL, Deaver JM. Use of thrombin and fibrinogen in skin grafting. Preliminary report. JAMA. 1944;124:976–978.CrossRef Cronkite EP, Lozner EL, Deaver JM. Use of thrombin and fibrinogen in skin grafting. Preliminary report. JAMA. 1944;124:976–978.CrossRef
6.
Zurück zum Zitat Cushner FD, Friedman RJ. Blood loss in total knee arthroplasty. Clin Orthop Relat Res. 1991;269:98–101.PubMed Cushner FD, Friedman RJ. Blood loss in total knee arthroplasty. Clin Orthop Relat Res. 1991;269:98–101.PubMed
7.
Zurück zum Zitat Good L, Peterson E, Lisander B. Tranexamic acid decreases external blood loss but not hidden blood loss in total knee replacement. Br J Anaesth. 2003;90:596–599.PubMedCrossRef Good L, Peterson E, Lisander B. Tranexamic acid decreases external blood loss but not hidden blood loss in total knee replacement. Br J Anaesth. 2003;90:596–599.PubMedCrossRef
8.
Zurück zum Zitat Kim HJ, Fraser MR, Kahn B, Lyman S, Figgie MP. The efficacy of a thrombin-based hemostatic agent in unilateral total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94:1160–1165.PubMed Kim HJ, Fraser MR, Kahn B, Lyman S, Figgie MP. The efficacy of a thrombin-based hemostatic agent in unilateral total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94:1160–1165.PubMed
9.
Zurück zum Zitat Levy O, Martinowitz U, Oran A, Tauber C, Horoszowski H. The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study. J Bone Joint Surg Am. 1999;81:1580–1588.PubMed Levy O, Martinowitz U, Oran A, Tauber C, Horoszowski H. The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study. J Bone Joint Surg Am. 1999;81:1580–1588.PubMed
10.
Zurück zum Zitat Lotke PA, Faralli VJ, Orenstein EM, Ecker ML. Blood loss after total knee replacement. Effects of tourniquet release and continuous passive motion. J Bone Joint Surg Am. 1991;73:1037–1040.PubMed Lotke PA, Faralli VJ, Orenstein EM, Ecker ML. Blood loss after total knee replacement. Effects of tourniquet release and continuous passive motion. J Bone Joint Surg Am. 1991;73:1037–1040.PubMed
11.
Zurück zum Zitat Mylod AG Jr, France MP, Muser DE, Parsons JR. Perioperative blood loss associated with total knee arthroplasty. A comparison of procedures performed with and without cementing. J Bone Joint Surg Am. 1990;72:1010–1012.PubMed Mylod AG Jr, France MP, Muser DE, Parsons JR. Perioperative blood loss associated with total knee arthroplasty. A comparison of procedures performed with and without cementing. J Bone Joint Surg Am. 1990;72:1010–1012.PubMed
12.
Zurück zum Zitat Parker MJ, Livingstone V, Clifton R, McKee A. Closed suction surgical wound drainage after orthopaedic surgery. Cochrane Database Syst Rev. 2007;3:CD001825.PubMed Parker MJ, Livingstone V, Clifton R, McKee A. Closed suction surgical wound drainage after orthopaedic surgery. Cochrane Database Syst Rev. 2007;3:CD001825.PubMed
13.
Zurück zum Zitat Raut VV, Stone MH, Wroblewski BM. Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am. 1993;75:1356–1357.PubMed Raut VV, Stone MH, Wroblewski BM. Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am. 1993;75:1356–1357.PubMed
14.
Zurück zum Zitat Rosencher N, Kerkkamp HE, Macheras G, Munuera LM, Menichella G, Barton DM, Cremers S, Abraham IL. Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion. 2003;43:459–469.PubMedCrossRef Rosencher N, Kerkkamp HE, Macheras G, Munuera LM, Menichella G, Barton DM, Cremers S, Abraham IL. Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion. 2003;43:459–469.PubMedCrossRef
15.
Zurück zum Zitat Sehat KR, Evans RL, Newman JH. Hidden blood loss following hip and knee arthroplasty. Correct management of blood loss should take hidden loss into account. J Bone Joint Surg Br. 2004;86:561–565.PubMed Sehat KR, Evans RL, Newman JH. Hidden blood loss following hip and knee arthroplasty. Correct management of blood loss should take hidden loss into account. J Bone Joint Surg Br. 2004;86:561–565.PubMed
16.
Zurück zum Zitat Wang GJ, Hungerford DS, Savory CG, Rosenberg AG, Mont MA, Burks SG, Mayers SL, Spotnitz WD. Use of fibrin sealant to reduce bloody drainage and hemoglobin loss after total knee arthroplasty: a brief note on a randomized prospective trial. J Bone Joint Surg Am. 2001;83:1503–1505.PubMed Wang GJ, Hungerford DS, Savory CG, Rosenberg AG, Mont MA, Burks SG, Mayers SL, Spotnitz WD. Use of fibrin sealant to reduce bloody drainage and hemoglobin loss after total knee arthroplasty: a brief note on a randomized prospective trial. J Bone Joint Surg Am. 2001;83:1503–1505.PubMed
17.
Zurück zum Zitat Watts CD, Pagnano MW. Minimising blood loss and transfusion in contemporary hip and knee arthroplasty. J Bone Joint Surg Br. 2012;94(Suppl):8–10.PubMedCrossRef Watts CD, Pagnano MW. Minimising blood loss and transfusion in contemporary hip and knee arthroplasty. J Bone Joint Surg Br. 2012;94(Suppl):8–10.PubMedCrossRef
18.
Zurück zum Zitat Wong J, Abrishami A, El Beheiry H, Mahomed NN, Roderick Davey J, Gandhi R, Syed KA, Muhammad Ovais Hasan S, De Silva Y, Chung F. Topical application of tranexamic acid reduces postoperative blood loss in total knee arthroplasty: a randomized, controlled trial. J Bone Joint Surg Am. 2010;92:2503–2513.PubMed Wong J, Abrishami A, El Beheiry H, Mahomed NN, Roderick Davey J, Gandhi R, Syed KA, Muhammad Ovais Hasan S, De Silva Y, Chung F. Topical application of tranexamic acid reduces postoperative blood loss in total knee arthroplasty: a randomized, controlled trial. J Bone Joint Surg Am. 2010;92:2503–2513.PubMed
19.
Zurück zum Zitat Yang ZG, Chen WP, Wu LD. Effectiveness and safety of tranexamic acid in reducing blood loss in total knee arthroplasty: a meta-analysis. J Bone Joint Surg Am. 2012;94:1153–1159.PubMed Yang ZG, Chen WP, Wu LD. Effectiveness and safety of tranexamic acid in reducing blood loss in total knee arthroplasty: a meta-analysis. J Bone Joint Surg Am. 2012;94:1153–1159.PubMed
Metadaten
Titel
Intraarticular Fibrinogen Does Not Reduce Blood Loss in TKA: A Randomized Clinical Trial
verfasst von
Thomas Jan Heyse, MD
Steven B. Haas, MD
Denise Drinkwater, BA
Stephen Lyman, PhD
Han Jo Kim, MD
Barbara A. Kahn, BS
Mark P. Figgie, MD
Publikationsdatum
01.01.2014
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2014
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-013-3036-1

Weitere Artikel der Ausgabe 1/2014

Clinical Orthopaedics and Related Research® 1/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.