Skip to main content
Erschienen in: Japanese Journal of Radiology 3/2018

11.01.2018 | Original Article

Investigation of an appropriate contrast-enhanced CT protocol for young patients following the Fontan operation

verfasst von: Motoo Nakagawa, Yoshiyuki Ozawa, Norikazu Nomura, Sachiko Inukai, Ayano Shiba, Keita Sakurai, Masashi Shimohira, Yuta Shibamoto

Erschienen in: Japanese Journal of Radiology | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Children with congenital heart diseases (CHDs) may need to be followed up with contrast-enhanced CT following the Fontan operation because complications such as the occlusion of conduits may occur. The purpose of the present study was to develop an adequate contrast-enhanced CT protocol for children with CHD following the Fontan operation.

Materials and methods

Between July 2012 and July 2017, 29 CT examinations for 26 patients aged 2–11 years (median 5 years) with CHD following the Fontan operation were performed using dual-source CT. A non-ionized contrast medium was injected through the dorsum manus vein. Scanning began 60 or 70 s after the start of the injection. The delayed phase was randomly selected to be 60 s in 14 cases and 70 s in 15 cases. We evaluated the enhancement of conduits following the Fontan operation at delayed phases.

Results

The CT numbers of conduits at 60 and 70 s were 185 ± 46 and 185 ± 31 HU, respectively (P = 0.97).

Conclusion

In contrast-enhanced CT for children after the Fontan operation, both of the delayed phases (60 and 70 s) appeared to be adequate for evaluating intraconduit patency.
Literatur
2.
Zurück zum Zitat Khanna G, Bhalla S, Krishnamurthy R, Canter C. Extracardiac complications of the Fontan circuit. Pediatr Radiol. 2012;42:233–41.CrossRefPubMed Khanna G, Bhalla S, Krishnamurthy R, Canter C. Extracardiac complications of the Fontan circuit. Pediatr Radiol. 2012;42:233–41.CrossRefPubMed
3.
Zurück zum Zitat Nakagawa M, Ozawa Y, Nomura N, Inukai S, Tsubokura S, Sakurai K, et al. Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects. Jpn J Radiol. 2016;34:284–91.CrossRefPubMed Nakagawa M, Ozawa Y, Nomura N, Inukai S, Tsubokura S, Sakurai K, et al. Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects. Jpn J Radiol. 2016;34:284–91.CrossRefPubMed
4.
Zurück zum Zitat Nakagawa M, Hara M, Oshima H, Shibamoto Y, Mizuno K, Asano M. Comparison of 16-multidetector-row computed tomography and angiocardiography for evaluating the central pulmonary artery diameter and pulmonary artery index in children with congenital heart disease. Radiat Med. 2008;26:337–42.CrossRefPubMed Nakagawa M, Hara M, Oshima H, Shibamoto Y, Mizuno K, Asano M. Comparison of 16-multidetector-row computed tomography and angiocardiography for evaluating the central pulmonary artery diameter and pulmonary artery index in children with congenital heart disease. Radiat Med. 2008;26:337–42.CrossRefPubMed
5.
Zurück zum Zitat Nakagawa M, Ozawa Y, Sakurai K, Shimohira M, Ohashi K, Asano M, et al. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease. Pediatr Radiol. 2015;45:1472–9.CrossRefPubMedPubMedCentral Nakagawa M, Ozawa Y, Sakurai K, Shimohira M, Ohashi K, Asano M, et al. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease. Pediatr Radiol. 2015;45:1472–9.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Shirota G, Maeda E, Namiki Y, Bari R, Ino K, Torigoe R, et al. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction. Pediatr Radiol. 2017;47:1463–70.CrossRefPubMedPubMedCentral Shirota G, Maeda E, Namiki Y, Bari R, Ino K, Torigoe R, et al. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction. Pediatr Radiol. 2017;47:1463–70.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Liu Y, Li J, Zhao H, Jia Y, Ren J, Xu J, et al. Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease. J Cardiothorac Surg. 2016;11:47.CrossRefPubMedPubMedCentral Liu Y, Li J, Zhao H, Jia Y, Ren J, Xu J, et al. Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease. J Cardiothorac Surg. 2016;11:47.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Rompel O, Glöckler M, Janka R, Dittrich S, Cesnjevar R, Lell MM, et al. Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction. Pediatr Radiol. 2016;46:462–72.CrossRefPubMed Rompel O, Glöckler M, Janka R, Dittrich S, Cesnjevar R, Lell MM, et al. Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction. Pediatr Radiol. 2016;46:462–72.CrossRefPubMed
9.
Zurück zum Zitat Greenberg SB, Bhutta ST. A dual contrast injection technique for multidetector computed tomography angiography of Fontan procedures. Int J Cardiovasc Imaging. 2008;24:345–8.CrossRefPubMed Greenberg SB, Bhutta ST. A dual contrast injection technique for multidetector computed tomography angiography of Fontan procedures. Int J Cardiovasc Imaging. 2008;24:345–8.CrossRefPubMed
10.
Zurück zum Zitat Wallihan DB, Podberesky DJ. Hepatic pathology after Fontan palliation: spectrum of imaging findings. Pediatr Radiol. 2013;43:330–8.CrossRefPubMed Wallihan DB, Podberesky DJ. Hepatic pathology after Fontan palliation: spectrum of imaging findings. Pediatr Radiol. 2013;43:330–8.CrossRefPubMed
11.
Zurück zum Zitat Park EA, Lee W, Chung SY, Yin YH, Chung JW, Park JH. Optimal scan timing and intravenous route for contrast-enhanced computed tomography in patients after Fontan operation. J Comput Assist Tomogr. 2010;34:75–81.CrossRefPubMed Park EA, Lee W, Chung SY, Yin YH, Chung JW, Park JH. Optimal scan timing and intravenous route for contrast-enhanced computed tomography in patients after Fontan operation. J Comput Assist Tomogr. 2010;34:75–81.CrossRefPubMed
12.
Zurück zum Zitat Nakagawa M, Hara M, Shibamoto Y. A prospective study to evaluate the depictability of the hepatic veins on abdominal contrast-enhanced CT in small children. Pediatr Radiol. 2009;39:933–7.CrossRefPubMed Nakagawa M, Hara M, Shibamoto Y. A prospective study to evaluate the depictability of the hepatic veins on abdominal contrast-enhanced CT in small children. Pediatr Radiol. 2009;39:933–7.CrossRefPubMed
13.
Zurück zum Zitat Heinemann M, Breuer J, Steger V, Steil E, Sieverding L, Ziemer G. Incidence and impact of systemic venous collateral development after Glenn and Fontan procedures. Thorac Cardiovasc Surg. 2001;49:172–8.CrossRefPubMed Heinemann M, Breuer J, Steger V, Steil E, Sieverding L, Ziemer G. Incidence and impact of systemic venous collateral development after Glenn and Fontan procedures. Thorac Cardiovasc Surg. 2001;49:172–8.CrossRefPubMed
14.
Zurück zum Zitat Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010;257:158–66.CrossRefPubMed Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010;257:158–66.CrossRefPubMed
15.
Zurück zum Zitat Boone J, Strauss K, Cody D, McCollough CH, McNitt-Gray MF, Toth TL. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. In: Report of AAPM Task Group 204. College Park: American Association of Physicists in Medicine; 2011. Boone J, Strauss K, Cody D, McCollough CH, McNitt-Gray MF, Toth TL. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. In: Report of AAPM Task Group 204. College Park: American Association of Physicists in Medicine; 2011.
16.
Zurück zum Zitat Marsden AL, Bernstein AJ, Reddy VM, Shadden SC, Spilker RL, Chan FP, et al. Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics. J Thorac Cardiovasc Surg. 2009;137:394–403.CrossRefPubMed Marsden AL, Bernstein AJ, Reddy VM, Shadden SC, Spilker RL, Chan FP, et al. Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics. J Thorac Cardiovasc Surg. 2009;137:394–403.CrossRefPubMed
17.
Zurück zum Zitat Sundareswaran KS, Haggerty CM, de Zélicourt D, Dasi LP, Pekkan K, Frakes DH, et al. Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging. J Thorac Cardiovasc Surg. 2012;143:1108–16.CrossRefPubMed Sundareswaran KS, Haggerty CM, de Zélicourt D, Dasi LP, Pekkan K, Frakes DH, et al. Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging. J Thorac Cardiovasc Surg. 2012;143:1108–16.CrossRefPubMed
18.
Zurück zum Zitat Prabhu SP, Mahmood S, Sena L, Lee EY. MDCT evaluation of pulmonary embolism in children and young adults following a lateral tunnel Fontan procedure: optimizing contrast-enhancement techniques. Pediatr Radiol. 2009;39:938–44.CrossRefPubMed Prabhu SP, Mahmood S, Sena L, Lee EY. MDCT evaluation of pulmonary embolism in children and young adults following a lateral tunnel Fontan procedure: optimizing contrast-enhancement techniques. Pediatr Radiol. 2009;39:938–44.CrossRefPubMed
19.
Zurück zum Zitat Hakim W, Kamanahalli R, Dick E, Bharwani N, Fetherston S, Kashef E. Trauma whole-body MDCT: an assessment of image quality in conventional dual-phase and modified biphasic injection. Br J Radiol. 2016;89:20160160.CrossRefPubMedPubMedCentral Hakim W, Kamanahalli R, Dick E, Bharwani N, Fetherston S, Kashef E. Trauma whole-body MDCT: an assessment of image quality in conventional dual-phase and modified biphasic injection. Br J Radiol. 2016;89:20160160.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Sugiyama H, Yoo SJ, Williams W, Benson LN. Characterization and treatment of systemic venous to pulmonary venous collaterals seen after the Fontan operation. Cardiol Young. 2003;13:424–30.PubMed Sugiyama H, Yoo SJ, Williams W, Benson LN. Characterization and treatment of systemic venous to pulmonary venous collaterals seen after the Fontan operation. Cardiol Young. 2003;13:424–30.PubMed
21.
Zurück zum Zitat Poterucha JT, Johnson JN, Taggart NW, Cabalka AK, Hagler DJ, Driscoll DJ, et al. Embolization of veno-venous collaterals after the Fontan operation is associated with decreased survival. Congenit Heart Dis. 2015;10:E230–6.CrossRefPubMed Poterucha JT, Johnson JN, Taggart NW, Cabalka AK, Hagler DJ, Driscoll DJ, et al. Embolization of veno-venous collaterals after the Fontan operation is associated with decreased survival. Congenit Heart Dis. 2015;10:E230–6.CrossRefPubMed
Metadaten
Titel
Investigation of an appropriate contrast-enhanced CT protocol for young patients following the Fontan operation
verfasst von
Motoo Nakagawa
Yoshiyuki Ozawa
Norikazu Nomura
Sachiko Inukai
Ayano Shiba
Keita Sakurai
Masashi Shimohira
Yuta Shibamoto
Publikationsdatum
11.01.2018
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 3/2018
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-018-0718-3

Weitere Artikel der Ausgabe 3/2018

Japanese Journal of Radiology 3/2018 Zur Ausgabe

Acknowledgment

Acknowledgment

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.