Is infrared thermometry suitable for the determination of the time since death based on ear temperature? A comparative study of two measurement methods

verfasst von: Kenza Laplace, Eric Baccino, Pierre-Antoine Peyron

Erschienen in: International Journal of Legal Medicine | Ausgabe 4/2021

Einloggen, um Zugang zu erhalten

Abstract

Infrared thermometry has been proposed as an interesting alternative to probe thermometers for recording ear temperature in cadavers to estimate the postmortem interval (PMI), but it has still to be validated in this setting. Our objective was to compare the performance of an infrared thermometer to that of a reference probe thermometer for measuring ear temperature. Temperature measurements were performed on 100 cadavers (mean PMI: 4.5 ± 2.5 h) using the infrared and the probe thermometers. The repeatability of the measurements, their correlation, and the agreement between both methods were evaluated. We showed a good repeatability of the measurements with the infrared thermometer (Lin’s concordance correlation coefficient (CCC) = 0.93 [0.72;0.98] for the right ear; CCC = 0.94 [0.75;0.98] for the left ear), and there was a strong and significant correlation between measurements provided by the two instruments (p < 0.001). However, a poor agreement was found between both methods, with a systematic underestimation of about 2 °C of the ear temperature when measured with the infrared thermometer. Data from auricular infrared thermometry should not be applied to algorithms developed for probe thermometers to estimate the PMI. Further research is needed to develop a reliable algorithm specifically based on infrared thermometry.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Benzinger TH, Taylor GW (1963) Cranial measurements of internal temperature in man. In: Herzfeld CM (ed) Temperature, its measurement and control in science and industry, 3, part 3: Biology and medicine. Reinhold, New York, pp 111–120 Benzinger TH, Taylor GW (1963) Cranial measurements of internal temperature in man. In: Herzfeld CM (ed) Temperature, its measurement and control in science and industry, 3, part 3: Biology and medicine. Reinhold, New York, pp 111–120
10.
Zurück zum Zitat Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal: part II: using single temperatures from this site to estimate the time since death with consideration of environmental or body “factors” that could affect the estimation. Forensic Sci Med Pathol 1:113–124. https://doi.org/10.1385/FSMP:1:2:113CrossRefPubMed Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal: part II: using single temperatures from this site to estimate the time since death with consideration of environmental or body “factors” that could affect the estimation. Forensic Sci Med Pathol 1:113–124. https://​doi.​org/​10.​1385/​FSMP:​1:​2:​113CrossRefPubMed
12.
Zurück zum Zitat Meusy A, Peyron P-A, Molinari N et al (2017) Étude préliminaire de l’exactitude et du biais systématique de deux thermomètres infrarouges pour l’estimation du délai post-mortem précoce : peut-on utiliser les thermomètres infrarouges commercialisés pour déterminer l’heure du décès ? Rev Médecine Légale 8:97–104. https://doi.org/10.1016/j.medleg.2017.04.002CrossRef Meusy A, Peyron P-A, Molinari N et al (2017) Étude préliminaire de l’exactitude et du biais systématique de deux thermomètres infrarouges pour l’estimation du délai post-mortem précoce : peut-on utiliser les thermomètres infrarouges commercialisés pour déterminer l’heure du décès ? Rev Médecine Légale 8:97–104. https://​doi.​org/​10.​1016/​j.​medleg.​2017.​04.​002CrossRef
13.
Zurück zum Zitat Rutty GN (2001) The use of temperatures recorded from the external auditory canal in the estimation of the time since death. Medical Doctorate Thesis, University of Sheffield, England Rutty GN (2001) The use of temperatures recorded from the external auditory canal in the estimation of the time since death. Medical Doctorate Thesis, University of Sheffield, England
14.
Zurück zum Zitat Rutty GN (2015) The use of temperatures recorded from the external auditory canal for the estimation of the post-mortem interval. In: Madea B (ed) Estimation of the time since death, 3rd edn. CRC Press, London, pp 134–151 Rutty GN (2015) The use of temperatures recorded from the external auditory canal for the estimation of the post-mortem interval. In: Madea B (ed) Estimation of the time since death, 3rd edn. CRC Press, London, pp 134–151
Metadaten
Titel
Is infrared thermometry suitable for the determination of the time since death based on ear temperature? A comparative study of two measurement methods
verfasst von
Kenza Laplace
Eric Baccino
Pierre-Antoine Peyron
Publikationsdatum
29.03.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 4/2021
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-021-02579-y

Neu im Fachgebiet Rechtsmedizin

Pathologie der Milz

Nach einer Beschreibung der Milzanatomie und Darstellung der diagnostisch wichtigsten immunhistochemischen Färbungen zur Identifizierung der normalen Milzkompartimente werden am Beispiel eines nordafrikanischen Patienten mit rezentem …

Molekular definierte Nierenzellkarzinome 2025

Im Zuge der Überarbeitung der WHO-Klassifikation im Jahr 2022 konnten für mehrere Nierenzellkarzinome (NZK), die sich zuvor nicht eindeutig den bis dahin definierten Tumortypen zuordnen ließen, jedoch gemeinsame morphologische und molekulare …

Wichtige Änderungen in der WHO-Klassifikation der Hodentumoren 2022

In der 5. Auflage der „WHO-Klassifikation der Tumoren der ableitenden Harnwege und des männlichen Genitaltrakts“ sind bedeutende Anpassungen an den bisherigen Klassifikationen vorgenommen worden. Diese betreffen bei den Keimzelltumoren des Hodens …

DNA mixture deconvolution using fully continuous models EuroForMix and EFMrep

  • Open Access
  • Originalien

Mixture deconvolution is a powerful tool for inferring individual DNA profiles from DNA mixtures for subsequent transmission to a database or database queries. To carry out deconvolution, a mixed trace can be interpreted either manually by an …