Skip to main content
Erschienen in: European Journal of Plastic Surgery 4/2018

Open Access 24.04.2018 | Original Paper

Is single-stage implant-based breast reconstruction (SSBR) with an acellular matrix safe?

Strattice™ or Meso Biomatrix® in SSBR

verfasst von: Nadine S. Hillberg, Patrick I. Ferdinandus, Rieky E. G. Dikmans, Bjorn Winkens, Juliette Hommes, René R. W. J. van der Hulst

Erschienen in: European Journal of Plastic Surgery | Ausgabe 4/2018

Abstract

Background

Acellular matrices (AM) might enable a direct single-stage breast reconstruction procedure resulting in an improved efficacy of the reconstruction phase for patients. Safety concerns are an important issue due to a recent study which shows that single-stage breast reconstruction with Strattice™ resulted in more complications versus a two-stage reconstruction. Therefore, the goal of this study is to compare the short- and long-term complications of a single-stage breast reconstruction with the use of two types of AM (Strattice™ and Meso Biomatrix®) versus two-stage breast reconstruction without the use of an AM.

Methods

Cohort study with single-stage breast reconstruction with Strattice™ (n = 28) or Meso BioMatrix® (n = 20) or two-stage breast reconstruction without an AM (n = 36) at the Maastricht Academic Hospital, the Netherlands. All complications, in particular major complications with the need for re-admission to the hospital, re-exploration, and implant explantation, were the primary outcome measures. A 1-year follow-up was achieved for all patients.

Results

Baseline characteristics of all 52 patients were similar between groups. There was a significantly higher complication rate in the single-stage AM groups with loss of the implant in 40.0% of the breasts from the Meso BioMatrix® group and in 10.7% of the Strattice™ group compared to no implant loss in the control group.

Conclusions

This cohort study clearly suggests that the use of a single-stage breast reconstruction is not safe with the use of these AMs. Well-designed prospective studies that guarantee the safety of those matrices should be published before these AMs are used in implant-based surgery.
Level of Evidence: Level III, risk / prognostic study.

Introduction

Many women develop breast cancer and desire immediate breast reconstruction following mastectomy [1]. Implants are the most frequently performed breast reconstruction technique after skin sparing mastectomy [2, 3]. Due to insufficient muscular coverage for subpectoral placement of a breast implant after mastectomy, a tissue expander (TE) is inserted in the majority of patients. During outpatient consultations, the TE is expanded repeatedly to create sufficient room for the definitive breast implant.
For patient and cost-efficiency reasons, a single-stage implant-based breast reconstruction (SSBR) would be more desirable than a two-stage breast reconstruction (TSBR). However, single-stage surgery increases the risk of complications [1]. Since the introduction of acellular matrix (AM) meshes in 2005, a safe single-stage implant-based breast reconstruction technique using AM might be possible [4]. In SSBR, these meshes can provide sufficient coverage for a breast implant where the pectoralis and serratus muscle do not cover the implant if inserted directly after a skin-sparing mastectomy. These meshes could be the missing link to facilitate a SSBR.
Some studies report the use of an AM in the USA in more than 60% of all alloplastic reconstructions [5, 6]. Currently, several meshes are used including Strattice™, Alloderm®, and more recent the Meso BioMatrix® [79]. Up to now, studies have shown inconsistent results on the risks associated with the additional use of AM’s in both SSBR and TSBR [1021]. Most studies summarize short-term safety using only one type of AM without a control group. Therefore, at the moment, there is no evidence which AM is the best. In 2013, a multicenter randomized clinical trial was started to compare the clinical outcomes and cost-effectiveness of a SSBR with Strattice™ with a TSBR without the use of AMs [22]. Our hospital included 40 patients for this study. After finishing the inclusion period for this study, Meso BioMatrix® entered the market and provided better matrix handling (Figs. 1 and 2), being more flexible and thin while maintaining strength. Therefore, patients who explicitly requested a single-stage procedure received a SSBR using Meso BioMatrix®.
The aim of this study was to assess the postoperative complications within 1 year associated with the use of Strattice™ and Meso BioMatrix® in implant-based breast reconstruction compared to a control group consisting of a TSBR without an AM.

Patients and methods

Study design

A single-center cohort study was done. Patients who participated in the BRIOS study at the Maastricht University Medical Centre were included [21]. These patients were randomly assigned into one of two groups. One group received immediate Strattice™ (LifeCell Corp., Branchburg, NJ, USA) assisted SSBR after mastectomy. The other group received an immediate, TSBR after mastectomy. Furthermore, a group of patients with immediate Meso BioMatrix® (DSM, Heerlen, The Netherlands) assisted implant-based breast reconstruction post-mastectomy was included. The latter group of patients did not take part in the BRIOS study and was not randomized.
The inclusion criteria for the BRIOS study met the inclusion criteria for the patients who received a breast reconstruction with the Meso BioMatrix®: women with BRCA gene mutation who underwent prophylactic treatment; women with a unifocal tumor smaller than 3–4 cm, intended to undergo a skin sparing mastectomy; willing and able to participate; aged 18 and over; and able to provide informed consent and able to complete questionnaires [21]. All patients where operated in the Maastricht University Medical Centre by one of the 12 plastic surgeons between May 2013 and March 2015.
Women with the following criteria were excluded in the BRIOS study as well in the Meso Biomatrix® group: a body mass index > 30 kg/m2; preferring a breast size larger than cup C; receiving a polyurethane implant; pregnant women; on-going severe psychiatric illness or mental retardation; evidence of alcohol and/or drug abuse; inability to complete questionnaires; a local or general infection which could jeopardize the surgical objective; an extensive local inflammatory reaction; proven or suspected hypersensitivity to materials; immunosuppressive pathologies; smokers; patients that would undergo postoperative radiotherapy.

Outcome measures

Demographic information, co-morbid conditions, surgery details, and additional details, regarding breast cancer treatment, were obtained. The postoperative follow-up period for all patients was 1 year. A major complication was defined as any complication requiring hospitalization or surgical intervention with or without implant loss. Major complications requiring surgery with loss of the implant were defined as ‘explantation’. Complications that did not require hospitalization or surgery were defined as minor complications.

Operative technique and postoperative management

The Strattice™ and control group received a single preoperative dose of cefazoline; in case of a penicillin allergy, erythromycin or clindamycin was given. The oncologic surgeon first performed a skin-sparing mastectomy before the plastic surgeon performed the SSBR or TSBR. A pocket was created under the major pectoral muscle to place the TE or implant. The cavity was cleaned with an antibiotic solution (cefaroxin 1000 mg/gentamicin 40 mg/betadine). During surgery, a ‘one touch’ technique of the implant was used and a ‘closed door’ policy was implemented to decrease the risk of infection. This means that the prosthesis or TE is touched once and only by the plastic surgeon and that the doors of the operating room remained closed in the period that the prosthesis was unpacked and handled by the plastic surgeon.
In the control group, the TE was placed in the pocket under the major pectoral muscle after which the major pectoral muscle was sutured together with the serratus/rectus fascia so the TE was fully covered by the muscle. After about 3 weeks, the TE will be expanded by multiple sessions of inflation with saline. The speed of inflation depended in particular on the size of the TE and the patient. Regular scheme is 50 cm3 perioperative fill and 50 cm3 per 2–3 weeks during the visit to the outpatient clinic. After the desired volume has been reached, the TE will be replaced for the final prosthesis in the second operation.
In the Strattice™ group, a sheet of Strattice™ was placed at the caudal side of the implant, sutured to the inferior margin of the musculus pectoralis major above and the inframammary crease below to complete the total pocket. Before use, the Strattice™ was washed in a saline solution as instructed by the manufacturer. In the Strattice™ group, two drains were placed: one anterior and one posterior to the matrix for at least 7 days. Postoperatively, the patients of the BRIOS study completed a 24-h regimen of cefazoline intravenously [21].
Because the Meso BioMatrix® group was not part of the BRIOS study, the operative technique was less standardized compared to the BRIOS study cases [21]. The Meso BioMatrix® group received, just as the BRIOS study, a single preoperative dose of cefazoline or same alternative in case of an allergy [21]. The ‘no touch’ and ‘closed door’ policy were similar, as was the operating technique to prepare a pocket and placing the Meso BioMatrix®. Before placement of the implant, the cavity and the wound-edges were cleaned with a betadine solution. The use of one or two drains differed between surgeons. The drains were removed with a production of less than 30 cm3/24 h per drain. Post-operative antibiotic prophylaxis consisted of another 5-day oral amoxicillin/clavulanic acid following a 24-h regimen of cefazoline intravenously.
All patients needed to wear a good fitting sports bra for at least 6 weeks post-operatively. The majority of patients were discharged from hospital with the drains in place. The drains were removed during a visit in the outpatient clinic or at home by nurses specialized in breast cancer care.
The patients included from the BRIOS study were randomized and treated following treatment protocol approved by the medical ethical committee [21]. The Meso Biomatrix® group consisted of a chart study. Therefore, this study was done in accordance with the Declaration of Helsinki and good clinical practice regulations.

Statistical analysis

Statistical analyses were performed using IBM SPSS Statistics [23]. The differences in demographics between groups were assessed using a one-way ANOVA for continuous variables and Chi-square tests, or Fischer’s exact tests where appropriate for categorical variables. The proportion of complications within 1 year was compared between groups using logistic regression analysis. As a sensitivity analysis, the results were checked with generalized estimating equations (GEE) which accounts for a possible correlation between outcomes of breasts belonging to the same patient.
Since the expected number of patients with major complications was limited, the group effect was separately corrected for one of the potential confounders. As BMI, age, active smoking, radiotherapy, and adjuvant therapy influence the chance for complications of breast implant reconstructions, these were considered as potential confounders [1, 10, 16, 17, 2427]. Major complications and explantations were combined, considering the expected low number of events. A p value ≤ 0.05 was considered to be statistically significant.

Results

Patient characteristics

In this study, 52 patients with 84 breasts were included. A 1-year follow-up was achieved for all patients. Twenty patients (38.5%) received a unilateral treatment and 32 patients (61.5%) received bilateral treatment. The reason for mastectomy was either prophylactic therapy in case of high hereditary risk for breast cancer (56%) or the presence of breast carcinoma (44%). Of all included patients, 21.4% of the breasts received a nipple-sparing mastectomy. A total of 15.5% of all breasts received an inframammary incision and 6% a partial peri areolar incision with a small extension lateral from the nipple. In one case in the TSBR, the tumor excision was incomplete with residual positive margins requiring re-excision.
The TSBR was performed in 36 breasts (43%), the SSBR using Strattice™ in 28 breasts (33%), and the SSBR with Meso BioMatrix® in 20 breasts (24%). In most cases, Eurosilicone implants (89.3%) were placed; Mentor (8.3%), Silimed (1.2%), and Allergan (1.2%) were used as well. All placed implants were textured. The mean volume of the placed implants was 370 cm3 for the Strattice™ group, 338 cm3 for the Meso BioMatrix® group, and 80 cm3 for the TE group. On average, six sessions (with variation from 4 till 11 sessions) of inflation were needed to reach the desired volume in the TE group.
Despite exclusion criteria for smoking and adjunctive breast radiation, 13.5% of the patients were active smokers during the perioperative period and 19.2% of the patients (10 breasts) received adjuvant radiotherapy; this was not significantly different between groups (Table 1). The start of the adjuvant radiotherapy differed between 28 and 192 days (mean 123 days) postoperatively. In six of these, a complication occurred. Except one case, all complications occurred before the start of the radiotherapy. In that one case, the breast received adjuvant radiotherapy 28 days postoperatively; then, 134 days later, an infection occurred with necrosis of the wound edge.
Table 1
Patient demographics of the different groups
 
Control group
SSBR with Strattice™
SSBR with Meso BioMatrix®
P value *
Patients, n
21
19
12
 
Age at operation, mean (SD), year
49.5 (10.9)
41.36 (11.7)
39.8 (13.9)
0.040
Smoking, n (% of patients)
3 (14.3%)
3 (15.8%)
1 (8.3%)
1.000F
BMI, mean (SD), kg/m2
21.8 (2.5)
22.7 (2.7)
21.1 (1.2)
0.199
DM, n (% of patients)
0
1 (5.3%)
0
0.596 F
ASA 2, n (% of patients)
11 (50.0%)
7 (36.8%)
6 (50%)
0.641
Neo adjuvant therapy, n (% of patients)
2 (9.5%)
5 (26.3%)
2 (16.7%)
0.364 F
Bilateral mastectomy, n (% of patients)
10 (47.6%)
11 (57.9%)
2 (16.7%)
0.073 F
Lymph node dissection, n (% of patients)
 No lymph node resection
6 (28.6%)
5 (26.3%)
7 (58.3%)
 
 Sentinel lymph node resection
14 (66.7%)
10 (52.6%)
5 (41.7%)
 
 Axillary lymph node dissection
1 (4.8%)
4 (21.1%)
0
 
Breasts, n
36
28
20
 
Adjuvant therapy, n (% of patients)
10 (47.6%)
11 (57.9%)
2 (16.7%)
0.073 F
Radiation, n (% of breasts)
4 (11.1%)
5 (17.9%)
1 (5.0%)
0.432 F
Prophylactic mastectomy, n (% of breasts)
20 (55.6%)
14 (50.0%)
13 (65.0%)
0.586
Oncologic mastectomy, n (% of breasts)
16 (44.4%)
14 (50.0%)
7 (35.0%)
0.586
Nipple sparing, n (% of breasts)
4 (11.1%)
5 (17.9%)
9 (45.0%)
0.016 F
Mastectomy incision, n (% of breasts)
 Vertical mastectomy incision
32(88.9%)
23 (82.1%)
11 (55%)
 
 Inframammary incision
4 (11.1%)
2 (7.1%)
7 (35%)
 
 Partial peri areolar incision with a small extension lateral to the nipple
0
3 (10.7%)
2 (10%)
 
Radical tumor excision
35 (97.2%)
28 (100%)
20 (100%)
1.000 F
Eurosilicone implant placed n (% of breasts)
29 (80.6%)
27 (96.4%)
19 (95.0%)
0.115 F
Definite implant volume cc, mean (SD)
379.7 (85.8)
370.0 (93.4)
337.5 (86.0)
0.229
*p value between groups were assessed by one-way ANOVA for numeric variables and Chi-square test or Fischer’s exact test for categorical variables. F = assessed by Fischer’s exact test
There was a statistically significant difference in age between the groups. The patients in the control group were older than in the Strattice™ or Meso BioMatrix® group. The patients in the Meso BioMatrix® group were on average younger, had a lower BMI, and fewer patients in this group received adjuvant chemotherapy and radiation therapy compared to the Strattice™ and control group. Thus on paper, the Meso BioMatrix® group was overall a more ideal patient group.

Complications and re-interventions

During the 1-year postoperative follow-up time, complications were encountered in 16.7% of the breasts of the control group, 32.1% of the Strattice™ group, and 55.0% of the Meso BioMatrix® group (Table 2, Fig. 3). Complications included wound infection, skin dehiscence, diathermal burn wound, hematoma, seroma, and skin ischemia. Major complications occurred in 55.0% of the breasts in the Meso BioMatrix® group, 21.4% of the breasts of the Strattice™ group, and 5.6% of the breasts of the control group. Explantation occurred in 40.0% of the breasts from the Meso BioMatrix® group and in 10.7% of the Strattice™ group compared to none in the control group. Patient demographics and reason of explantation are shown in Table 3.
Table 2
Complication rates between the groups
 
Control (n = 36)
Strattice™ (n = 28)
Meso BioMatrix® (n = 20)
Total breasts with complications, n (%)
6 (16.7%)
9 (32.1%)
11 (55.0%)*
Infection
0
1 (1.3%)
5 (25%)
Hematoma
3 (8.3%)
0
1 (5%)
Necrosis of woundedge
1(2.8%)
5 (17.9%)
3 (15%)
Ischemic skin
0
0
2 (10%)
Edema
0
1 (3.5%)
0
Seroma
1 (2.8%)
2 (7.0%)
0
Postoperative bleeding
0
1 (3.5%)
0
Burnwound from ablation
1 (2.8%)
0
0
Dehiscence
1 (2.8%)
4 (14.3%)
1 (5%)
Minor n (%)
4 (11.1%)
3 (10.7%)
0
Major n (%)
2 (5.6%)
6 (21.4%)
11 (55.0%)*
Explantation n (%)
0(0.0%)
3(10.7%)**
8(40.0%)**
*Statistically significant (p < 0.05) compared to the control group
**Percentages of the groups Strattic™ or Meso Biomatrix®, respectively
Table 3
Per patient descriptive statistics if explantation occurred (n = 11)
Mesh
S
S
S
MB
MB
MB
MB
MB
MB
MB
MB
Age at operation, year
30
38
42
74
43
30
30
56
43
43
30
Smoking
No
No
Yes
No
No
No
No
Yes
?a
No
?a
BMI, kg/m2
22
23
22
23
20
21
21
22
23
23
19
DM
No
No
No
No
No
No
No
No
No
No
No
Neoadjuvant therapy
No
Yes
No
No
No
No
No
No
Yes
Yes
No
Bilateral mastectomy
Yes
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Adjuvant therapy
Yes
Yes
No
No
No
No
No
No
No
No
No
Radiation
No
No
No
No
No
No
No
No
No
No
Yes
Prophylactic mastectomy
No
No
Yes
No
No
Yes
Yes
Yes
No
No
No
Oncologic mastectomy
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Yes
Yes
Definitive implant volume, cc
370
410
410
290
435
320
320
515
410
410
320
Reason of explantation
EP
EP
EP
IN
EP
IE
IN
IN
EP
EP
EP
Time between operation and explantation, days
353
71
38
189
10
56
52
27
56
56
122
S Strattice™, MB Meso BioMatrix®, EP exposed prosthesis or mesh, IS ischemic skin, IN infection
aMissing

Meso BioMatrix® group versus control group

The Meso BioMatrix® group had a significantly higher complication rate than the control group (p = 0.004) (Table 3). After correcting for potential confounders, the results were similar and remained significant, irrespective of which potential confounder was corrected for. As for major complications, the same conclusion could be drawn with the effect being even larger (OR = 20.8; p < 0.001).

Strattice™ group versus control group

For total complications, major complications, and explantation, there were no significant differences in the Strattice™ group versus the control group (total complications: p = 0.153, major complications p = 0.075, explantation p = 0.079), irrespective of correcting for the potential confounders.

Meso BioMatrix® group versus Strattice™ group

The Meso BioMatrix® group showed significantly more major complications within 1 year compared to the Strattice™ group (p = 0.020). After correcting for the potential confounders, the results were similar and remained significant, irrespective of which potential confounder was corrected for (Table 4).
As for GEE analyses that accounts for the form of within-subject correlation if a patient had the breast reconstruction of both breasts, the results remained similar in all analyses and therefore yield the same conclusions.

Discussion

Innovation is crucial in the field of plastic and reconstructive surgery. In this study, the use of acellular matrices (AMs) in implant-based breast reconstruction is reported using a single-stage breast reconstruction technique (SSBR). Postoperative complications between the two groups of patients with a SSBR with an AM, either Strattice™ made of porcine skin or Meso Biomatrix® made of porcine peritoneum, were compared to the two-stage implant-based breast reconstruction (TSBR). These groups of patients showed that the complication rate in the AM groups was much higher (32.1% in the Strattice™ group and 55.0% in the Meso BioMatrix® group) compared to the TSBR (16.7%) and significantly higher numbers of explantation (0 versus 10.7% in the Strattice™ group and 40.0% in the Meso Biomatrix® group). As AMs are widely used globally, it is of crucial importance to deliver high-quality evidence on the safety of these additional ‘implants’ inserted in patients. Registration in (inter)national independent opt-out implant registry could be of indispensable help in the prospective data sampling of all acellular (dermal) matrices to understand its implications for patient safety.
The amount of complications in the patients treated with a TSBR without a mesh was comparable to what is described in the literature [16, 28]. Nevertheless, the complication rates reported in the studies of Davila et al. and Collis et al. were much lower (5.4 and 7.4%) which might be due to a short follow-up (30 days) and not including minor complications with no need for further treatment [19, 29]. The higher amount of complications in the Strattice™ group compared to the control group has been replicated in the recently published randomized controlled trial described by Dikmans et al [22]. Our complication rate observed in the SSBR with the use Strattice™ is also comparable to what is described by Lardi et al [25]. However, the complication and explantation rate found in our study are significantly higher than the findings in Salzberg et al [8]. This could be the result of selection bias with a high inclusion rate of oncologic patients with adjuvant radiotherapy or (neo-) adjuvant chemotherapy.
The Meso BioMatrix® group experienced complications in 55.0% of the breasts and explantation in 40.0% of the breasts. Zero minor complications in the Meso Biomatrix® group suggests a detection bias of the cohort study, implying not precise enough reports of minor complications in the (outpatient) clinic. A prospective controlled study might thus reveal even higher complication rates in this Meso Biomatrix® group. To our knowledge, no studies have published the use of Meso BioMatrix® in SSBR yet. One trial is registered and is still including patients [30]. Therefore, the only comparison that can be made is with other types of AM [8, 1113, 18, 24, 31]. In line with the previous studies, Meso BioMatrix® gives significantly more complications than described in other studies using AMs in a SSBR, where different kinds of AMs seem to have acceptable complication rates [8, 1113, 18, 24, 31].
Table 4
Differences in total and major complication rate (within 1 year) between control group, Meso Biomatrix®, and Strattice™ group, after correction for no or one potential confounder
  
Meso Biomatrix® versus control
Strattice™ versus control
Meso Biomatrix® versus Strattice™
Total complications
Corrected for
OR
95%CI
p value
OR
95%CI
p value
OR
95%CI
p value
6.1
1.8–21.2
0.004
2.4
0.7–7.7
0.153
2.6
0.8–8.4
0.117
Age
10.0
2.1–47.9
0.004
2.5
0.7–9.4
0.163
3.2
0.9–11.5
0.079
Smoking
6.7
1.7–26.3
0.007
2.5
0.7–8.1
0.143
2.8
0.8–10.7
0.123
BMI
12.8
2.5–65.1
0.002
1.8
0.5–6.6
0.347
4.5
1.1–18.1
0.034
Radiotherapy
8.2
2.1–31.9
0.003
2.2
0.6–7.6
0.206
3.4
0.9–12.0
0.061
Adjuvant therapy
8.7
2.0–37.2
0.003
2.3
0.7–7.8
0.171
3.7
0.9–14.4
0.061
Major complications
20.8
3.9–111.1
<0.001
4.6
0.9–25.1
0.075
4.5
1.3–15.8
0.020
Age
40.7
4.7–351.1
0.001
3.2
0.5–19.5
0.205
5.0
1.3–18.6
0.016
Smoking
24.1
3.9–148.6
0.001
4.7
0.9–25.4
0.074
5.1
1.2–21.1
0.023
BMI
37.7
4.4–319.8
0.001
3.8
0.7–21.5
0.128
7.2
1.6–32.4
0.010
Radiotherapy
37.6
4.3–328.0
0.001
4.4
0.8–24.6
0.094
5.8
1.5–22.9
0.012
Adjuvant therapy
42.8
4.4–416.5
0.001
4.8
0.8–28.1
0.080
8.9
1.7–47.0
0.010
Differences in complication rates in this study as well as in the literature could be explained by the mesh itself. Alloderm® is made out of human dermis; Strattice™ and Meso Biomatrix® are, respectively, obtained from porcine dermis and porcine mesothelial peritoneum. Instructions for use, the feel, and handling of these AMs are thus different, which assumes to also deem important for the result (function, esthetic, and complications) [3234]. Interestingly, an SSBR with Alloderm® is suggested to have lower numbers of complications than generally found in the literature on SSBR and Strattice™ and especially compared to the complication rates found in this study. Hunsicker et al. recently published its 13 years of cumulative experience that showed a significantly lower complication rate compared to our study. In this study, several meshes were used of which 93% concerning Alloderm and only 6.9% Strattice and 0.1% FlexHD. These authors did not made a distinction in the complication rate per mesh, but found an overall complication rate of only 10% using an AM with SSBR [21]. Limitations in methodology (cohort/chart studies; single center, multiple surgeons, learning curve per surgeon); the general conclusion from all these studies is that we do not know how safe the use of an AM is, and how different complication rates between AMs are listed.
Seroma formation is a feared complication for surgeons, which might be higher when using AMs versus not using AMs. High rates of seroma formation have been described with the use of AM. In this study, we only observed three cases with seroma with one patient belonging to the control group (two-staged) and the other two in the Strattice group (9 and 25 days postoperative).
Questionable is to what extent the complications are caused by the single-stage procedure itself (versus for example patient characteristics) and whether the meshes play the pivotal role in this. Atiyeh et al. indicate that a SSBR without the use of a mesh could be done safely and that the final results largely depend on the status of the tissues after mastectomy [35, 36]. Colwell et al. also state that SSBR with or without using a mesh after nipple-sparing mastectomy could have a low complication rate if the patient is properly selected [37]. In an attempt to understand the role of AMs, we corrected for patient characteristics using as potential confounders including BMI, age at operation, adjuvant chemotherapy, radiotherapy, and active smoking behavior. The results were similar after correcting for these potential confounders separately. We have chosen these confounders based on possible risk factors for complications in implant-based breast reconstruction found in the literature [1, 10, 16, 2427].
An important detail of this study was that complications that required explantation in both AM groups occurred rather late: in the Strattice™ group a median of 69 days (25–349 days) and in the Meso BioMatrix® group a median of 54 days (10–187 days). This emphasizes the need for a long follow-up when AMs are used. Barber et al. also reported the late occurrence of complications using a variety of AMs in breast reconstructive procedures with a median time until loss of implant of 73 days with a range of 9–895 days [10]. Currently, there is a lack of studies that examine the complications of AMs with a follow-up of several years. Moreover, studies seldom classify the time between implantation and complication occurrence although it is of significant importance for the outcome and of great interest for the doctor and the patient.
Limitations of this cohort study design are the risk of selection bias and detection bias in the Meso Biomatrix® group as explained earlier. Based on the patient demographics, however, the Meso BioMatrix® group contained a more favorable patient profile than the other two groups. The protocols of the two studies were slightly different from one another regarding the following: the postoperative prophylactic antibiotic regime, the amount of time that the drains were used, and the operative techniques. However, it is rather unlikely that these small variations explain the differences in complication rates between Strattice™ and Meso BioMatrix®. After all, most complications occurred in the Meso BioMatrix® group, despite the difference in drain- and antibiotic prophylaxis regime, which can be considered an advantage for the Meso BioMatrix® group. Considering that prolonged drain use can be associated with postoperative infection and although 24 h of prophylactic postoperative antibiotics seems equivalent to extended oral antibiotics for infections of TE-based breast reconstruction, it is not certain if this is also the case in SSBR with AMs [2, 38]. Nevertheless, despite of the limitations in the study, it does establish a strong suggestion.
All the surgeries were done in the same hospital performed by 12 plastic surgeons. In all three groups, the procedures were carried out by different plastic surgeons. The emergence of a complication did not seem to be associated with the plastic surgeon performing the operation. Insufficient soft tissue is an important aspect to predict complications. Unfortunately, there are no validated instruments to measure soft tissue quality. All surgeons would not place an implant if there were doubts on flap viability. Besides the complications, we did not compare possible improvement of appearance of the reconstructed breast or patient reported outcomes such as the quality of life between these groups. Even though the latter outcomes are rather important aspects of patient care, we are convinced that the first and foremost is the patient safety.

Conclusion

This study suggests that the two-stage implant-based breast reconstruction without AMs is noticeably safer than the single-stage implant-based breast reconstruction with Strattice™ or Meso BioMatrix®. Before using an acellular (dermal) matrix in single-stage implant-based breast reconstructions, high-quality prospective studies on the safety of this procedure should be performed. An (inter)national implant registry could be of great value for post market surveillance of these innovations.

Compliance with ethical standards

Conflict of interest

Nadine S. Hillberg, Patrick I. Ferdinandus, Rieky E. G. Dikmans, Bjorn Winkens, Juliette Hommes and René R. van der Hulst declare that they have no conflict of interest.

Funding

The acellular matrix products were provided by the manufacturer without expense for the patient or hospital. Strattice™ was delivered as part of the BRIOS study. Meso BioMatrix® was provided by the manufacturer as part of the introduction to the Dutch market.

Ethical approval

This study was done in accordance with the Declaration of Helsinki and good clinical practice regulations.
Written consent was obtained from all patients included in this study.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Dent – Das Online-Abo der Zahnmedizin

Online-Abonnement

Mit e.Dent erhalten Sie Zugang zu allen zahnmedizinischen Fortbildungen und unseren zahnmedizinischen und ausgesuchten medizinischen Zeitschriften.

Literatur
1.
Zurück zum Zitat Petersen A, Eftekhari AL, Damsgaard TE (2012) Immediate breast reconstruction: a retrospective study with emphasis on complications and risk factors. J Plast Surg Hand Surg 46(5):344–348CrossRefPubMed Petersen A, Eftekhari AL, Damsgaard TE (2012) Immediate breast reconstruction: a retrospective study with emphasis on complications and risk factors. J Plast Surg Hand Surg 46(5):344–348CrossRefPubMed
2.
Zurück zum Zitat Hanna KR, Tilt A, Holland M, Colen D, Bowen B, Stovall M, Lee A, Wang J, Drake D, Lin K, Uroskie T, Campbell CA (2016) Reducing infectious complications in implant based breast reconstruction: impact of early expansion and prolonged drain use. Ann Plast Surg 76:S312–S315CrossRefPubMed Hanna KR, Tilt A, Holland M, Colen D, Bowen B, Stovall M, Lee A, Wang J, Drake D, Lin K, Uroskie T, Campbell CA (2016) Reducing infectious complications in implant based breast reconstruction: impact of early expansion and prolonged drain use. Ann Plast Surg 76:S312–S315CrossRefPubMed
3.
Zurück zum Zitat American society of Plastic Surgeons 2011. Accessed April 2016 American society of Plastic Surgeons 2011. Accessed April 2016
4.
Zurück zum Zitat Breuing KH, Warren SM (2005) Immediate bilateral breast reconstruction with implants and inferolateral AlloDerm slings. Ann Plast Surg 55(3):232–239CrossRefPubMed Breuing KH, Warren SM (2005) Immediate bilateral breast reconstruction with implants and inferolateral AlloDerm slings. Ann Plast Surg 55(3):232–239CrossRefPubMed
5.
6.
Zurück zum Zitat Nguyen KT, Mioton LM, Smetona JT, Seth AK, Kim JY (2012) Esthetic outcomes of ADM-assisted expander-implant breast reconstruction. Eplasty 12:e58PubMedPubMedCentral Nguyen KT, Mioton LM, Smetona JT, Seth AK, Kim JY (2012) Esthetic outcomes of ADM-assisted expander-implant breast reconstruction. Eplasty 12:e58PubMedPubMedCentral
7.
Zurück zum Zitat Luo X, Kulig KM, Finkelstein EB, et al. (2015) In vitro evaluation of decellularized ECM-derived surgical scaffold biomaterials. J Biomed Mater Res B Appl Biomater Luo X, Kulig KM, Finkelstein EB, et al. (2015) In vitro evaluation of decellularized ECM-derived surgical scaffold biomaterials. J Biomed Mater Res B Appl Biomater
8.
Zurück zum Zitat Salzberg CA, Dunavant C, Nocera N (2013) Immediate breast reconstruction using porcine acellular dermal matrix (Strattice): long-term outcomes and complications. J Plast Reconstr Aesthet Surg 66(3):323–328CrossRefPubMed Salzberg CA, Dunavant C, Nocera N (2013) Immediate breast reconstruction using porcine acellular dermal matrix (Strattice): long-term outcomes and complications. J Plast Reconstr Aesthet Surg 66(3):323–328CrossRefPubMed
9.
Zurück zum Zitat Pannucci CJ, Antony AK, Wilkins EG (2013) The impact of acellular dermal matrix on tissue expander/implant loss in breast reconstruction: an analysis of the tracking outcomes and operations in plastic surgery database. Plast Reconstr Surg 132(1):1–10CrossRefPubMed Pannucci CJ, Antony AK, Wilkins EG (2013) The impact of acellular dermal matrix on tissue expander/implant loss in breast reconstruction: an analysis of the tracking outcomes and operations in plastic surgery database. Plast Reconstr Surg 132(1):1–10CrossRefPubMed
10.
Zurück zum Zitat Barber MD, Williams L, Anderson ED et al (2015) Outcome of the use of acellular-dermal matrix to assist implant-based breast reconstruction in a single Centre. Eur J Surg Oncol 41(1):100–105CrossRefPubMed Barber MD, Williams L, Anderson ED et al (2015) Outcome of the use of acellular-dermal matrix to assist implant-based breast reconstruction in a single Centre. Eur J Surg Oncol 41(1):100–105CrossRefPubMed
11.
Zurück zum Zitat JoAnna Nguyen T, Carey JN, Wong AK (2011) Use of human acellular dermal matrix in implant- based breast reconstruction: evaluating the evidence. J Plast Reconstr Aesthet Surg 64(12):1553–1561CrossRefPubMed JoAnna Nguyen T, Carey JN, Wong AK (2011) Use of human acellular dermal matrix in implant- based breast reconstruction: evaluating the evidence. J Plast Reconstr Aesthet Surg 64(12):1553–1561CrossRefPubMed
12.
Zurück zum Zitat Himsl I, Drinovac V, Lenhard M, Stockl D, Weissenbacher T, Dian D (2012) The use of porcine acellular dermal matrix in silicone implant-based breast reconstruction. Arch Gynecol Obstet 286(1):187–192CrossRefPubMed Himsl I, Drinovac V, Lenhard M, Stockl D, Weissenbacher T, Dian D (2012) The use of porcine acellular dermal matrix in silicone implant-based breast reconstruction. Arch Gynecol Obstet 286(1):187–192CrossRefPubMed
13.
Zurück zum Zitat Lee KT, Mun GH (2016) Updated evidence of acellular dermal matrix use for implant-based breast reconstruction: a meta-analysis. Ann Surg Oncol 23(2):600–610CrossRefPubMed Lee KT, Mun GH (2016) Updated evidence of acellular dermal matrix use for implant-based breast reconstruction: a meta-analysis. Ann Surg Oncol 23(2):600–610CrossRefPubMed
14.
Zurück zum Zitat Vu MM, De Oliveira GS, Jr., Mayer KE, Blough JT, Kim JY. A prospective study assessing complication rates and patient-reported outcomes in breast reconstructions using a novel, deep dermal human acellular dermal matrix. Plast Reconstr Surg Glob Open 2015;3(12):e585 Vu MM, De Oliveira GS, Jr., Mayer KE, Blough JT, Kim JY. A prospective study assessing complication rates and patient-reported outcomes in breast reconstructions using a novel, deep dermal human acellular dermal matrix. Plast Reconstr Surg Glob Open 2015;3(12):e585
15.
Zurück zum Zitat Gschwantler-Kaulich D, Schrenk P, Bjelic-Radisic V, Unterrieder K, Leser C, Fink-Retter A, Salama M, Singer C (2016) Mesh versus acellular dermal matrix in immediate implant-based breast reconstruction - a prospective randomized trial. Eur J Surg Oncol 42(5):665–671CrossRefPubMed Gschwantler-Kaulich D, Schrenk P, Bjelic-Radisic V, Unterrieder K, Leser C, Fink-Retter A, Salama M, Singer C (2016) Mesh versus acellular dermal matrix in immediate implant-based breast reconstruction - a prospective randomized trial. Eur J Surg Oncol 42(5):665–671CrossRefPubMed
16.
Zurück zum Zitat Skovsted Yde S, Brunbjerg ME, Damsgaard TE (2016) Acellular dermal matrices in breast reconstructions - a literature review. J Plast Surg Hand Surg:1–10 Skovsted Yde S, Brunbjerg ME, Damsgaard TE (2016) Acellular dermal matrices in breast reconstructions - a literature review. J Plast Surg Hand Surg:1–10
17.
Zurück zum Zitat Ho G, Nguyen TJ, Shahabi A, Hwang BH, Chan LS, Wong AK (2012) A systematic review and meta-analysis of complications associated with acellular dermal matrix-assisted breast reconstruction. Ann Plast Surg 68(4):346–356CrossRefPubMed Ho G, Nguyen TJ, Shahabi A, Hwang BH, Chan LS, Wong AK (2012) A systematic review and meta-analysis of complications associated with acellular dermal matrix-assisted breast reconstruction. Ann Plast Surg 68(4):346–356CrossRefPubMed
18.
Zurück zum Zitat Colwell AS DB, Zahedi B, Medford-Davis L, Hertl C, Austen WG Jr. Retrospective review of 331 consecutive immediate single-staged implant reconstructions with acellular dermal matrix: indications, complications, trends, and costs. Plast Reconstr Surg 2011;128(6):1170–1178. Colwell AS DB, Zahedi B, Medford-Davis L, Hertl C, Austen WG Jr. Retrospective review of 331 consecutive immediate single-staged implant reconstructions with acellular dermal matrix: indications, complications, trends, and costs. Plast Reconstr Surg 2011;128(6):1170–1178.
19.
Zurück zum Zitat Collis GN, TerKonda SP, Waldorf JC, Perdikis G (2012) Acellular dermal matrix slings in tissue expander breast reconstruction: are there substantial benefits? Ann Plast Surg 68(5):425–428CrossRefPubMed Collis GN, TerKonda SP, Waldorf JC, Perdikis G (2012) Acellular dermal matrix slings in tissue expander breast reconstruction: are there substantial benefits? Ann Plast Surg 68(5):425–428CrossRefPubMed
20.
Zurück zum Zitat Potter S, Browning D, Savovic J, Holcombe C, Blazeby JM (2015) Systematic review and critical appraisal of the impact of acellular dermal matrix use on the outcomes of implant-based breast reconstruction. Br J Surg 102(9):1010–1025CrossRefPubMed Potter S, Browning D, Savovic J, Holcombe C, Blazeby JM (2015) Systematic review and critical appraisal of the impact of acellular dermal matrix use on the outcomes of implant-based breast reconstruction. Br J Surg 102(9):1010–1025CrossRefPubMed
21.
Zurück zum Zitat Hunsicker LM, Ashikari AY, Berry C, Koch RM, Salzberg CA (2017) Short-term complications associated with acellular dermal matrix-assisted direct-to-implant breast reconstruction. Ann Plast Surg 78(1):35–40CrossRefPubMed Hunsicker LM, Ashikari AY, Berry C, Koch RM, Salzberg CA (2017) Short-term complications associated with acellular dermal matrix-assisted direct-to-implant breast reconstruction. Ann Plast Surg 78(1):35–40CrossRefPubMed
22.
Zurück zum Zitat Dikmans REG, Negenborn VL, Bouman MB et al. (2017) Two-stage implant-based breast reconstruction compared with immediate one-stage implant-based breast reconstruction augmented with an acellular dermal matrix: an open-label, phase 4, multicentre, randomised, controlled trial. Lancet Oncol 18(2):251–258 Dikmans REG, Negenborn VL, Bouman MB et al. (2017) Two-stage implant-based breast reconstruction compared with immediate one-stage implant-based breast reconstruction augmented with an acellular dermal matrix: an open-label, phase 4, multicentre, randomised, controlled trial. Lancet Oncol 18(2):251–258
23.
Zurück zum Zitat IMB SPSS statistics 23 [computer program] IMB SPSS statistics 23 [computer program]
24.
Zurück zum Zitat Mitchell RE (2013) Porcine acellular dermis-assisted breast reconstruction: influence of adjuvant radiotherapy on complications and outcomes. Plast Reconstr Surg Glob Open 1(8):e77CrossRefPubMedPubMedCentral Mitchell RE (2013) Porcine acellular dermis-assisted breast reconstruction: influence of adjuvant radiotherapy on complications and outcomes. Plast Reconstr Surg Glob Open 1(8):e77CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Lardi AM, Ho-Asjoe M, Mohanna PN, Farhadi J (2014) Immediate breast reconstruction with acellular dermal matrix: factors affecting outcome. J Plast Reconstr Aesthet Surg 67(8):1098–1105CrossRefPubMed Lardi AM, Ho-Asjoe M, Mohanna PN, Farhadi J (2014) Immediate breast reconstruction with acellular dermal matrix: factors affecting outcome. J Plast Reconstr Aesthet Surg 67(8):1098–1105CrossRefPubMed
26.
Zurück zum Zitat Fischer JP, Nelson JA, Serletti JM, Wu LC (2013) Peri-operative risk factors associated with early tissue expander (TE) loss following immediate breast reconstruction (IBR): a review of 9305 patients from the 2005-2010 ACS-NSQIP datasets. J Plast Reconstr Aesthet Surg 66(11):1504–1512CrossRefPubMed Fischer JP, Nelson JA, Serletti JM, Wu LC (2013) Peri-operative risk factors associated with early tissue expander (TE) loss following immediate breast reconstruction (IBR): a review of 9305 patients from the 2005-2010 ACS-NSQIP datasets. J Plast Reconstr Aesthet Surg 66(11):1504–1512CrossRefPubMed
27.
Zurück zum Zitat Kato H, Nakagami G, Iwahira Y, Otani R, Nagase T, Iizaka S, Tamai N, Matsuyama Y, Sanada H (2013) Risk factors and risk scoring tool for infection during tissue expansion in tissue expander and implant breast reconstruction. Breast J 19(6):618–626CrossRefPubMed Kato H, Nakagami G, Iwahira Y, Otani R, Nagase T, Iizaka S, Tamai N, Matsuyama Y, Sanada H (2013) Risk factors and risk scoring tool for infection during tissue expansion in tissue expander and implant breast reconstruction. Breast J 19(6):618–626CrossRefPubMed
28.
Zurück zum Zitat Kim JY, Davila AA, Persing S et al (2012) A meta-analysis of human acellular dermis and submuscular tissue expander breast reconstruction. Plast Reconstr Surg 129(1):28–41CrossRefPubMed Kim JY, Davila AA, Persing S et al (2012) A meta-analysis of human acellular dermis and submuscular tissue expander breast reconstruction. Plast Reconstr Surg 129(1):28–41CrossRefPubMed
29.
Zurück zum Zitat Davila AA, Mioton LM, Chow G, Wang E, Merkow RP, Bilimoria KY, Fine N, Kim JYS (2013) Immediate two-stage tissue expander breast reconstruction compared with one-stage permanent implant breast reconstruction: a multi-institutional comparison of short-term complications. J Plast Surg Hand Surg 47(5):344–349CrossRefPubMed Davila AA, Mioton LM, Chow G, Wang E, Merkow RP, Bilimoria KY, Fine N, Kim JYS (2013) Immediate two-stage tissue expander breast reconstruction compared with one-stage permanent implant breast reconstruction: a multi-institutional comparison of short-term complications. J Plast Surg Hand Surg 47(5):344–349CrossRefPubMed
30.
Zurück zum Zitat NCT01823107. Feasibility study of meso BioMatrix device for breast reconstruction NCT01823107. Feasibility study of meso BioMatrix device for breast reconstruction
31.
Zurück zum Zitat Cassileth L, Kohanzadeh S, Amersi F (2012) One-stage immediate breast reconstruction with implants: a new option for immediate reconstruction. Ann Plast Surg 69(2):134–138CrossRefPubMed Cassileth L, Kohanzadeh S, Amersi F (2012) One-stage immediate breast reconstruction with implants: a new option for immediate reconstruction. Ann Plast Surg 69(2):134–138CrossRefPubMed
32.
Zurück zum Zitat Corporation L (2015) Strattice reconstructive tissue matrix instructions for use. February Corporation L (2015) Strattice reconstructive tissue matrix instructions for use. February
35.
Zurück zum Zitat Atiyeh B, Papazian N, Becker H, Dibo S, Ibrahim A (2015) Erratum to: simplified skin excision pattern for skin-sparing/reducing mastectomy and direct-to-implant single-stage immediate (DISSI) breast reconstruction. Eur J Plast Surg 38(4):299–300CrossRef Atiyeh B, Papazian N, Becker H, Dibo S, Ibrahim A (2015) Erratum to: simplified skin excision pattern for skin-sparing/reducing mastectomy and direct-to-implant single-stage immediate (DISSI) breast reconstruction. Eur J Plast Surg 38(4):299–300CrossRef
36.
Zurück zum Zitat Ibrahim AE, Atiyeh BS, Dibo SA, Sarhane KA, Abbas JS (2012) De-epithelialized dermal barrier for a safe immediate prosthetic breast reconstruction post circumvertical skin sparing/reducing mastectomy (SSM/SRM). Eur J Plast Surg 35(11):787–793CrossRef Ibrahim AE, Atiyeh BS, Dibo SA, Sarhane KA, Abbas JS (2012) De-epithelialized dermal barrier for a safe immediate prosthetic breast reconstruction post circumvertical skin sparing/reducing mastectomy (SSM/SRM). Eur J Plast Surg 35(11):787–793CrossRef
37.
Zurück zum Zitat Colwell AS, Christensen JM (2017) Nipple-sparing mastectomy and direct-to-implant breast reconstruction. Plast Reconstr Surg 140(5S Advances in Breast Reconstruction):44s–50sCrossRefPubMed Colwell AS, Christensen JM (2017) Nipple-sparing mastectomy and direct-to-implant breast reconstruction. Plast Reconstr Surg 140(5S Advances in Breast Reconstruction):44s–50sCrossRefPubMed
38.
Zurück zum Zitat Phillips BT, Fourman MS, Bishawi M, Zegers M, O'Hea BJ, Ganz JC, Huston TL, Dagum AB, Khan SU, Bui DT (2016) Are prophylactic postoperative antibiotics necessary for immediate breast reconstruction? Results of a prospective randomized clinical trial. J Am Coll Surg 222:1116–1124CrossRefPubMed Phillips BT, Fourman MS, Bishawi M, Zegers M, O'Hea BJ, Ganz JC, Huston TL, Dagum AB, Khan SU, Bui DT (2016) Are prophylactic postoperative antibiotics necessary for immediate breast reconstruction? Results of a prospective randomized clinical trial. J Am Coll Surg 222:1116–1124CrossRefPubMed
Metadaten
Titel
Is single-stage implant-based breast reconstruction (SSBR) with an acellular matrix safe?
Strattice™ or Meso Biomatrix® in SSBR
verfasst von
Nadine S. Hillberg
Patrick I. Ferdinandus
Rieky E. G. Dikmans
Bjorn Winkens
Juliette Hommes
René R. W. J. van der Hulst
Publikationsdatum
24.04.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Plastic Surgery / Ausgabe 4/2018
Print ISSN: 0930-343X
Elektronische ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-018-1415-2

Weitere Artikel der Ausgabe 4/2018

European Journal of Plastic Surgery 4/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.