Skip to main content
Erschienen in: Critical Care 1/2020

Open Access 01.12.2020 | Research Letter

Is there still a place for transcranial Doppler in patients with IABP?

verfasst von: Juliana R. Caldas, Ronney B. Panerai, Rogério Passos, Ludhmila A. Hajjar

Erschienen in: Critical Care | Ausgabe 1/2020

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Transcranial Doppler (TCD), a relatively inexpensive and noninvasive tool, is often used to identify emboli, stenosis, vasospasm, brain death, and cerebral autoregulation (CA) [1]. When monitoring patients with intra-aortic balloon pump (IABP), the largest study published with TCD did not show neurological complications or deterioration of CA [2], but the occurrence of abnormal reverse cerebral blood flow velocity (CBFV) was not investigated.
Diastolic flow reversal in CBFV has been described in patients with IABP [3]. This pattern implies negative CBFV in late diastole and has also been described in intracranial hypertension, brain death, and comatose patients [4]. However, the clinical significance of this dramatic alteration in the CBFV waveform pattern is still unknown.
We assessed the effect of CBFV reversal on CA, in patients with IABP, as part of a randomized clinical trial [2]. After ethical approval, we included patients submitted to elective cardiac surgery, who presented reverse CBFV and provided written informed consent.
CBFV (TCD) and intra-arterial blood pressure (BP) were performed over 5 min with the IABP operating a 1:3 ratio triggered by the electrocardiogram. Second measurement was performed for 5 min without pumping assistance soon after IABP was turned OFF.
CA was assessed by autoregulation index (ARI), with impaired CA defined as ARI < 4 [2].
Paired Student’s t test or Wilcoxon tests were used as appropriate.
Six of 34 patients with IABP presented CBFV reversal, aged 63.9 ± 7.9 years, EuroSCORE 5 [range 3–7], and echocardiogram LVEF 40% [35–45].
CBFV (p = 0.68) and BP (p = 0.08) did not show any differences between IABP-ON and IABP-OFF (Table 1).
Table 1
Cerebral hemodynamic parameters and dynamic CA with IABP ON and IABP off
Patient number
  
IABP
ON
   
IABP
OFF
  
 
ARI#
(mmHg)
HR (bpm)
CBFV
MCA (cm/s)
ETCO2 (mmHg)
ARI#
(mmHg)
HR (bpm)
CBFV
MCA (cm/s)
ETCO2 (mmHg)
25
0
84.9
86.6
87.9
32
1.6
81.6
84.7
88.1
32
35
1.8
77.5
81.7
33.9
33
3.9
94.2
87.0
15.8
35
65
2.3
67.3
121.2
80.4
35
5.1
63.9
123.8
85.6
35
95
2.4
60.1
100.5
89.2
29
7.9
89.7
102.5
86.9
29
96
1.6
43.1
96.2
91.4
38
3.9
81.3
90.3
95.1
38
97
5.6
65.6
113.1
40.1
32
6.1
78.2
114.4
42.4
32
ARI autoregulation index, EtCO2 end- tidal CO2, MAP mean arterial pressure, HR heart rate, CBFV cerebral blood flow velocity, MCA middle cerebral artery
#p < 0.05 (Wilcoxon tests) for the comparison between IABP ON and IABP OFF
For IABP-ON, ARI was 2.0 [0.0–5.6] and 4.5 [1.6–2.6] for IABP-OFF (p = 0.028).
Five patients showed impaired CA with IABP-ON; however, only 3 showed impaired CA with IABP-OFF (p = 0.545). All patients increased the ARI on IABP-OFF, when compared with IABP-ON. None of the patients had a stroke or a diagnosis of brain injury, but two patients died and another two had delirium [2].
Our previous study found that IABP did not impair CA [2], but with CBFV reversal, we observed that CA was affected and the ARI increased in all patients when IABP was removed. This finding indicates that TCD can play an important role in the assessment of patients with IABP and we suggest a systematic approach for this purpose in Fig. 1. The main use of TCD in this context is to identify and manage the potential complications of CA impairment, to prevent the deleterious effects of changes in BP, leading to ischemia or hyperperfusion [1].
CBFV reversal in IABP occurred in 17% of our cases, although it can occur in up to 35% of patients with IABP [3]. Reversal of diastolic CBFV at late diastole is probably due to rapid deflation of IABP [5], with the suggestion that CBFV reversal is iatrogenic and should be avoided. One possible approach is to optimize the balloon inflation/deflation cycle, by moving deflation to the absolute end of diastole [5]. The precise effects of CBFV reversal on cerebral hemodynamics is still unknown; its departure from normal physiological waveforms likely to be undesirable and to have a negative effect on CA.
Furthermore, negative CBFV is a TCD pattern in brain death [4]. For this reason, in IABP patients with suspected brain-death, the IABP has to be on standby to allow determination of the main source of CBFV reversal (Fig. 1).
TCD is also important to detect microemboli in IABP (Fig. 1), a cause of cerebral infarct and commonly iatrogenic in origin, often reported in cardiothoracic surgery [6]. This complication in patients with IABP, when there is a rupture with gas embolization, is rare, but potentially fatal.
Larger studies are needed in IABP patients with reverse CBFV to assess their cerebral hemodynamics and neurological outcomes.

Acknowledgements

The participation of all patients is gratefully acknowledged.
This study was approved by the local research ethics committee (approval number: 835.731), and written informed consent was provided of all subjects.
Not applicable.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Robba C, Taccone FS. How I use transcranial Doppler. Crit Care. 2019;23:420.CrossRef Robba C, Taccone FS. How I use transcranial Doppler. Crit Care. 2019;23:420.CrossRef
2.
Zurück zum Zitat Caldas JR, Panerai RB, Bor-Seng-Shu E, Ferreira GSR, Camara L, Passos RH, et al. Intra-aortic balloon pump does not influence cerebral hemodynamics and neurological outcomes in high-risk cardiac patients undergoing cardiac surgery: an analysis of the IABCS trial. Ann Intensive Care. 2019;9:130.CrossRef Caldas JR, Panerai RB, Bor-Seng-Shu E, Ferreira GSR, Camara L, Passos RH, et al. Intra-aortic balloon pump does not influence cerebral hemodynamics and neurological outcomes in high-risk cardiac patients undergoing cardiac surgery: an analysis of the IABCS trial. Ann Intensive Care. 2019;9:130.CrossRef
3.
Zurück zum Zitat Schachtrupp A, Wrigge H, Busch T, Buhre W, Weyland A. Influence of intra-aortic balloon pumping on cerebral blood flow pattern in patients after cardiac surgery. Eur J Anaesthesiol. 2005;22:165–70.CrossRef Schachtrupp A, Wrigge H, Busch T, Buhre W, Weyland A. Influence of intra-aortic balloon pumping on cerebral blood flow pattern in patients after cardiac surgery. Eur J Anaesthesiol. 2005;22:165–70.CrossRef
4.
Zurück zum Zitat van der Naalt J, Baker AJ. Influence of the intra-aortic balloon pump on the transcranial Doppler flow pattern in a brain-dead patient. Stroke. 1996;27:140–2.CrossRef van der Naalt J, Baker AJ. Influence of the intra-aortic balloon pump on the transcranial Doppler flow pattern in a brain-dead patient. Stroke. 1996;27:140–2.CrossRef
5.
Zurück zum Zitat Gao YZ, Zhang M. Effect of intra-aortic balloon pump on reversal of diastolic cerebral flow: deflated too early? Neurocrit Care. 2018;29(2):313–4. Gao YZ, Zhang M. Effect of intra-aortic balloon pump on reversal of diastolic cerebral flow: deflated too early? Neurocrit Care. 2018;29(2):313–4.
6.
Zurück zum Zitat Grover G, Perera AH, Hamady M, Rudarakanchana N, Barras CD, Singh A, et al. Cerebral embolic protection in thoracic endovascular aortic repair. J Vasc Surg. 2018;68:1656–66.CrossRef Grover G, Perera AH, Hamady M, Rudarakanchana N, Barras CD, Singh A, et al. Cerebral embolic protection in thoracic endovascular aortic repair. J Vasc Surg. 2018;68:1656–66.CrossRef
Metadaten
Titel
Is there still a place for transcranial Doppler in patients with IABP?
verfasst von
Juliana R. Caldas
Ronney B. Panerai
Rogério Passos
Ludhmila A. Hajjar
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2020
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-020-03324-4

Weitere Artikel der Ausgabe 1/2020

Critical Care 1/2020 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.