Abstract

The pattern electroretinogram (PERG) is a retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document from the International Society for Clinical Electrophysiology of Vision (www.​iscev.​org) is a scheduled revision of the ISCEV PERG Standard, which updates and replaces the 2007 update and all earlier versions. The standard defines a single minimum stimulus and recording protocol for clinical PERG testing to assist practitioners in obtaining good quality responses and to facilitate inter-laboratory comparison. The present revision tightens stimulus specifications, expands on steady-state PERG recording, addresses visual stimulus display distinctions (CRT vs. LCD), and provides a more explicit definition of response components.
Literatur
1.
Zurück zum Zitat Marmor MF, Holder GE, Porciatti V, Trick GL, Zrenner E (1996) Guidelines for basic pattern electroretinography. Recommendations by the International Society for Clinical Electrophysiology of Vision. Doc Ophthalmol 91:291–298CrossRef Marmor MF, Holder GE, Porciatti V, Trick GL, Zrenner E (1996) Guidelines for basic pattern electroretinography. Recommendations by the International Society for Clinical Electrophysiology of Vision. Doc Ophthalmol 91:291–298CrossRef
2.
Zurück zum Zitat Bach M, Hawlina M, Holder GE, Marmor MF, Meigen T, Vaegan, Miyake Y (2000) Standard for pattern electroretinography. Doc Ophthalmol 101:11–18PubMedCrossRef Bach M, Hawlina M, Holder GE, Marmor MF, Meigen T, Vaegan, Miyake Y (2000) Standard for pattern electroretinography. Doc Ophthalmol 101:11–18PubMedCrossRef
3.
Zurück zum Zitat Holder GE, Brigell MG, Hawlina M, Meigen T, Vaegan, Bach M (2007) ISCEV standard for clinical pattern electroretinography—2007 update. Doc Ophthalmol 114:111–116PubMedCrossRef Holder GE, Brigell MG, Hawlina M, Meigen T, Vaegan, Bach M (2007) ISCEV standard for clinical pattern electroretinography—2007 update. Doc Ophthalmol 114:111–116PubMedCrossRef
4.
Zurück zum Zitat Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Marmor MF, McCulloch DL, Palmowski-Wolfe AM (2012) ISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition). Doc Ophthalmol 124:1–13PubMedCrossRef Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Marmor MF, McCulloch DL, Palmowski-Wolfe AM (2012) ISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition). Doc Ophthalmol 124:1–13PubMedCrossRef
5.
Zurück zum Zitat Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, International Society for Clinical Electrophysiology of Vision (2008) ISCEV Standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77PubMedCrossRef Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, International Society for Clinical Electrophysiology of Vision (2008) ISCEV Standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77PubMedCrossRef
6.
Zurück zum Zitat Marmor MF, Brigell MG, McCulloch DL, Westall CA, Bach M (2011) ISCEV standard for clinical electro-oculography (2010 update). Doc Ophthalmol 122:1–7PubMedCrossRef Marmor MF, Brigell MG, McCulloch DL, Westall CA, Bach M (2011) ISCEV standard for clinical electro-oculography (2010 update). Doc Ophthalmol 122:1–7PubMedCrossRef
7.
Zurück zum Zitat Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119PubMedCrossRef Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119PubMedCrossRef
8.
Zurück zum Zitat Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193PubMedCrossRef Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193PubMedCrossRef
Metadaten
Titel
ISCEV standard for clinical pattern electroretinography (PERG): 2012 update
verfasst von
Michael Bach
Mitchell G. Brigell
Marko Hawlina
Graham E. Holder
Mary A. Johnson
Daphne L. McCulloch
Thomas Meigen
Suresh Viswanathan
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Documenta Ophthalmologica / Ausgabe 1/2013
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-012-9353-y

Weitere Artikel der Ausgabe 1/2013

Documenta Ophthalmologica 1/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.