Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 2/2015

01.04.2015 | Editorial

Journal of clinical monitoring and computing 2014 end of year summary: respiration

verfasst von: D. S. Karbing, S. E. Rees, M. B. Jaffe

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 2/2015

Einloggen, um Zugang zu erhalten

Excerpt

Endotracheal intubation allows a clear airway for positive pressure ventilation and protects the respiratory tract from aspiration of gastric contents. However, placing the endotracheal tube is difficult in some patients with the risk of damaging the airways. In addition, placing the endotracheal tube in the esophagus can occur with potentially fatal consequences. Three papers were published in Journal of Clinical Monitoring and Computing during 2014 on visualization of the airways during endotracheal intubation and for verification of correct placement. …
Literatur
1.
Zurück zum Zitat Saricicek V, Mizrak A, Gul R, Goksu S, Cesur M. GlideScope video laryngoscopy use tracheal intubation in patients with ankylosing spondylitis: a series of four cases and literature review. J Clin Monit Comput. 2014;28:169–72.CrossRefPubMed Saricicek V, Mizrak A, Gul R, Goksu S, Cesur M. GlideScope video laryngoscopy use tracheal intubation in patients with ankylosing spondylitis: a series of four cases and literature review. J Clin Monit Comput. 2014;28:169–72.CrossRefPubMed
2.
Zurück zum Zitat Karippacheril JG, Umesh G, Ramkumar V. Inexpensive video-laryngoscopy guided intubation using a personal computer: initial experience of a novel technique. J Clin Monit Comput. 2014;28:261–4.CrossRefPubMed Karippacheril JG, Umesh G, Ramkumar V. Inexpensive video-laryngoscopy guided intubation using a personal computer: initial experience of a novel technique. J Clin Monit Comput. 2014;28:261–4.CrossRefPubMed
3.
Zurück zum Zitat Goethals P, Chaobal H, Reynaerts D, Schaner D. A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement. J Clin Monit Comput. 2014;28:179–85.CrossRefPubMed Goethals P, Chaobal H, Reynaerts D, Schaner D. A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement. J Clin Monit Comput. 2014;28:179–85.CrossRefPubMed
4.
Zurück zum Zitat Agustí AGN, Barberà JA. Contribution of multiple inert gas elimination technique to pulmonary medicine 2—Chronic pulmonary diseases: chronic obstructive pulmonary disease and idiopathic pulmonary fibrosis. Thorax. 1994;49:924–32.CrossRefPubMedCentralPubMed Agustí AGN, Barberà JA. Contribution of multiple inert gas elimination technique to pulmonary medicine 2—Chronic pulmonary diseases: chronic obstructive pulmonary disease and idiopathic pulmonary fibrosis. Thorax. 1994;49:924–32.CrossRefPubMedCentralPubMed
5.
Zurück zum Zitat Mélot C. Contribution of multiple inert gas elimination technique to pulmonary medicine 5—ventilation-perfusion relationships in acute respiratory failure. Thorax. 1994;49:1251–8.CrossRefPubMedCentralPubMed Mélot C. Contribution of multiple inert gas elimination technique to pulmonary medicine 5—ventilation-perfusion relationships in acute respiratory failure. Thorax. 1994;49:1251–8.CrossRefPubMedCentralPubMed
6.
Zurück zum Zitat Czaplik M, Antink CH, Rossaint R, Leonhardt S. Application of internal electrodes to the oesophageal and tracheal tube in an animal trial: evaluation of its clinical and technical potentiality in electrical impedance tomography. J Clin Monit Comput. 2014;28:299–308.CrossRefPubMed Czaplik M, Antink CH, Rossaint R, Leonhardt S. Application of internal electrodes to the oesophageal and tracheal tube in an animal trial: evaluation of its clinical and technical potentiality in electrical impedance tomography. J Clin Monit Comput. 2014;28:299–308.CrossRefPubMed
7.
Zurück zum Zitat Karsten J, Krabbe K, Heinze H, Dalhoff K, Meier T, Drömann D. Bedside monitoring of ventilation distribution and alveolar inflammation in community-acquired pneumonia. J Clin Monit Comput. 2014;28:403–8.CrossRefPubMed Karsten J, Krabbe K, Heinze H, Dalhoff K, Meier T, Drömann D. Bedside monitoring of ventilation distribution and alveolar inflammation in community-acquired pneumonia. J Clin Monit Comput. 2014;28:403–8.CrossRefPubMed
8.
Zurück zum Zitat Sapsford DJ, Jones JG. The PIO2 vs SpO2 diagram: a non-invasive measurement of pulmonary oxygen exchange. Eur J Anaesth. 1995;12:375–86. Sapsford DJ, Jones JG. The PIO2 vs SpO2 diagram: a non-invasive measurement of pulmonary oxygen exchange. Eur J Anaesth. 1995;12:375–86.
9.
Zurück zum Zitat Rees SE, Kjargaard S, Thorgaard P, Malczynski J, Toft E, Andreassen S. The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10–15 minutes. J Clin Monit Comput. 2002;17:43–52.CrossRefPubMed Rees SE, Kjargaard S, Thorgaard P, Malczynski J, Toft E, Andreassen S. The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10–15 minutes. J Clin Monit Comput. 2002;17:43–52.CrossRefPubMed
10.
Zurück zum Zitat Lockwood GG, Fung NLS, Jones JG. Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch. J Clin Monit Comput. 2014;28:581–90.CrossRefPubMed Lockwood GG, Fung NLS, Jones JG. Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch. J Clin Monit Comput. 2014;28:581–90.CrossRefPubMed
11.
Zurück zum Zitat Thomsen LP, Weinreich UM, Karbing DS, Wagner PD, Rees SE. Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD. J Clin Monit Comput. 2014;28:547–58.CrossRefPubMed Thomsen LP, Weinreich UM, Karbing DS, Wagner PD, Rees SE. Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD. J Clin Monit Comput. 2014;28:547–58.CrossRefPubMed
12.
Zurück zum Zitat Roske K, Foitzik B, Wauer RR, Schmalisch G. Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices. J Clin Monit Comput. 1998;14:413–20.CrossRefPubMed Roske K, Foitzik B, Wauer RR, Schmalisch G. Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices. J Clin Monit Comput. 1998;14:413–20.CrossRefPubMed
13.
Zurück zum Zitat Proquitté H, Wendel R, Roehr CC, Wauer RR, Schmalisch G. Dead space reduction by Kolobow’s endotracheal tube does not justify the waiving of volume monitoring in small, ventilated lungs. J Clin Monit Comput. 2014;28:605–11.CrossRefPubMed Proquitté H, Wendel R, Roehr CC, Wauer RR, Schmalisch G. Dead space reduction by Kolobow’s endotracheal tube does not justify the waiving of volume monitoring in small, ventilated lungs. J Clin Monit Comput. 2014;28:605–11.CrossRefPubMed
14.
Zurück zum Zitat Hartdorff CM, van Heerde M, Markhorst DG. Bench test assessment of mainstream capnography during high frequency oscillatory ventilation. J Clin Monit Comput. 2014;28(1):63–6.CrossRefPubMed Hartdorff CM, van Heerde M, Markhorst DG. Bench test assessment of mainstream capnography during high frequency oscillatory ventilation. J Clin Monit Comput. 2014;28(1):63–6.CrossRefPubMed
15.
Zurück zum Zitat Vinay B, Sriganesh K. Krishna KNG (2014) An abrupt reduction in end-tidal carbon-dioxide during neurosurgery is not always due to venous air embolism: a capnograph artefact. J Clin Monit Comput. 2014;28(2):217–9.CrossRefPubMed Vinay B, Sriganesh K. Krishna KNG (2014) An abrupt reduction in end-tidal carbon-dioxide during neurosurgery is not always due to venous air embolism: a capnograph artefact. J Clin Monit Comput. 2014;28(2):217–9.CrossRefPubMed
16.
Zurück zum Zitat Singh M, Chaudhary K, Uppal R, Jain S. Beware of ‘‘curare cleft’’ like changes during unilateral capnothorax. J Clin Monit Comput. 2014;28(3):315–8.CrossRefPubMed Singh M, Chaudhary K, Uppal R, Jain S. Beware of ‘‘curare cleft’’ like changes during unilateral capnothorax. J Clin Monit Comput. 2014;28(3):315–8.CrossRefPubMed
17.
Zurück zum Zitat Yang J, Wang H, Wang B, Wang L. Accurate and stable continuous monitoring module by mainstream capnography. J Clin Monit Comput. 2014;28(4):363–9.CrossRefPubMed Yang J, Wang H, Wang B, Wang L. Accurate and stable continuous monitoring module by mainstream capnography. J Clin Monit Comput. 2014;28(4):363–9.CrossRefPubMed
18.
Zurück zum Zitat Gravenstein JS, Jaffe MB, Paulus DA, editors. Capnography: Clinical Aspects. 1st ed. New York: Cambridge University Press; 2004, p. 441. Gravenstein JS, Jaffe MB, Paulus DA, editors. Capnography: Clinical Aspects. 1st ed. New York: Cambridge University Press; 2004, p. 441.
19.
Zurück zum Zitat Standards for Basic Anesthetic Monitoring, American Society of Anesthesiologists, Committee of Origin: Standards and Practice Parameters (Approved by the ASA House of Delegates on October 21, 1986, and last amended on October 20, 2010 with an effective date of July 1, 2011). Standards for Basic Anesthetic Monitoring, American Society of Anesthesiologists, Committee of Origin: Standards and Practice Parameters (Approved by the ASA House of Delegates on October 21, 1986, and last amended on October 20, 2010 with an effective date of July 1, 2011).
20.
Zurück zum Zitat Hazinski MF, Nolan JP, Billi JE, Böttiger BW, Bossaert L, de Caen AR, Deakin CD, Drajer S, Eigel B, Hickey RW, Jacobs I, Kleinman ME, Kloeck W, Koster RW, Lim SH, Mancini ME, Montgomery WH, Morley PT, Morrison LJ, Nadkarni VM, O’Connor RE, Okada K, Perlman JM, Sayre MR, Shuster M, Soar J, Sunde K, Travers AH, Wyllie J, Zideman D. Part 1: executive summary: 2010 International consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Circulation. 2010;122(16 Suppl 2):S250–75.CrossRefPubMed Hazinski MF, Nolan JP, Billi JE, Böttiger BW, Bossaert L, de Caen AR, Deakin CD, Drajer S, Eigel B, Hickey RW, Jacobs I, Kleinman ME, Kloeck W, Koster RW, Lim SH, Mancini ME, Montgomery WH, Morley PT, Morrison LJ, Nadkarni VM, O’Connor RE, Okada K, Perlman JM, Sayre MR, Shuster M, Soar J, Sunde K, Travers AH, Wyllie J, Zideman D. Part 1: executive summary: 2010 International consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Circulation. 2010;122(16 Suppl 2):S250–75.CrossRefPubMed
21.
Zurück zum Zitat Dreyfuss D, Saumon G. Ventilator-induced lung injury: lessons from experimental studies. Am J Respir Crit Care Med. 1998;157:294–323.CrossRefPubMed Dreyfuss D, Saumon G. Ventilator-induced lung injury: lessons from experimental studies. Am J Respir Crit Care Med. 1998;157:294–323.CrossRefPubMed
22.
Zurück zum Zitat Tanaka PP, Tanaka M, Drover DR. Detection of respiratory compromise by acoustic monitoring, capnography, and brain function monitoring during monitored anesthesia care. J Clin Monit Comput. 2014;28:561–6.CrossRefPubMed Tanaka PP, Tanaka M, Drover DR. Detection of respiratory compromise by acoustic monitoring, capnography, and brain function monitoring during monitored anesthesia care. J Clin Monit Comput. 2014;28:561–6.CrossRefPubMed
24.
Zurück zum Zitat Ganigara A, Ramavakoda CY. Continuous real time endotracheal tube cuff pressure waveform. J Clin Monit Comput. 2014;28:433–4.CrossRefPubMed Ganigara A, Ramavakoda CY. Continuous real time endotracheal tube cuff pressure waveform. J Clin Monit Comput. 2014;28:433–4.CrossRefPubMed
25.
Zurück zum Zitat Buehler S, Lozano-Zahonero S, Schumann S, Guttmann J. Monitoring of intratidal lung mechanics: a graphical user interface for a model-based decision support system for PEEPtitration in mechanical ventilation. J Clin Monit Comput. 2014;28:613–23.CrossRefPubMed Buehler S, Lozano-Zahonero S, Schumann S, Guttmann J. Monitoring of intratidal lung mechanics: a graphical user interface for a model-based decision support system for PEEPtitration in mechanical ventilation. J Clin Monit Comput. 2014;28:613–23.CrossRefPubMed
26.
Zurück zum Zitat Schumann S, Burcza B, Haberthur C, Lichtwarck-Aschoff M, Guttmann J. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method. Physiol Meas. 2009;30:1341–56.CrossRefPubMed Schumann S, Burcza B, Haberthur C, Lichtwarck-Aschoff M, Guttmann J. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method. Physiol Meas. 2009;30:1341–56.CrossRefPubMed
27.
Zurück zum Zitat The Acute Respiratory Distress Syndrome(ARDS) Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301–8.CrossRef The Acute Respiratory Distress Syndrome(ARDS) Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301–8.CrossRef
28.
Zurück zum Zitat Schultz MJ, Wolthuis EK, Moeniralam HS, Levi M. Struggle for implementation of new strategies in intensive care medicine: anticoagulation, insulin, and lower tidal volumes. J Crit Care. 2005;20:199–206.CrossRefPubMed Schultz MJ, Wolthuis EK, Moeniralam HS, Levi M. Struggle for implementation of new strategies in intensive care medicine: anticoagulation, insulin, and lower tidal volumes. J Crit Care. 2005;20:199–206.CrossRefPubMed
29.
Zurück zum Zitat Allerød C, Karbing DS, Thorgaard P, Andreassen S, Kjærgaard S, Rees SE. Variability of preference toward mechanical ventilator settings: a model-based behavioral analysis. J Crit Care. 2011;26:637-e5–12.CrossRef Allerød C, Karbing DS, Thorgaard P, Andreassen S, Kjærgaard S, Rees SE. Variability of preference toward mechanical ventilator settings: a model-based behavioral analysis. J Crit Care. 2011;26:637-e5–12.CrossRef
30.
Zurück zum Zitat Banner MJ, Euliano NR, Grooms D, Martin AS, Al-Rawas N, Gabrielli A. Oxygenation advisor recommends appropriate positive end expiratory pressure and FIO2 settings: retrospective validation study. J Clin Monit Comput. 2014;28:203–10.CrossRefPubMed Banner MJ, Euliano NR, Grooms D, Martin AS, Al-Rawas N, Gabrielli A. Oxygenation advisor recommends appropriate positive end expiratory pressure and FIO2 settings: retrospective validation study. J Clin Monit Comput. 2014;28:203–10.CrossRefPubMed
31.
Zurück zum Zitat Wysocki M, Jouvet P, Jaber S. Closed loop mechanical ventilation. J Clin Monit Comput. 2014;28:49–56.CrossRefPubMed Wysocki M, Jouvet P, Jaber S. Closed loop mechanical ventilation. J Clin Monit Comput. 2014;28:49–56.CrossRefPubMed
32.
Zurück zum Zitat Schädler D, Mersmann S, Frerichs I, Elke G, Semmel-Griebeler T, Noll O, Pulletz S, Zick G, David M, Heinrichs W, Scholz J, Weiler N. A knowledge- and model-based system for automated weaning from mechanical ventilation: technical description and first clinical application. J Clin Monit Comput. 2014;28:487–98.CrossRefPubMed Schädler D, Mersmann S, Frerichs I, Elke G, Semmel-Griebeler T, Noll O, Pulletz S, Zick G, David M, Heinrichs W, Scholz J, Weiler N. A knowledge- and model-based system for automated weaning from mechanical ventilation: technical description and first clinical application. J Clin Monit Comput. 2014;28:487–98.CrossRefPubMed
33.
Zurück zum Zitat Kretschmer J, Haunsberger T, Drost E, Koch E, Möller K. Simulating physiological interactions in a hybrid system of mathematical models. J Clin Monit Comput. 2014;28:513–23.CrossRefPubMed Kretschmer J, Haunsberger T, Drost E, Koch E, Möller K. Simulating physiological interactions in a hybrid system of mathematical models. J Clin Monit Comput. 2014;28:513–23.CrossRefPubMed
34.
Zurück zum Zitat Baldoli I, Tognarelli S, Cecchi F, Scaramuzzo RT, Ciantelli M, Gentile M, Cuttano A, Laschi C, Menciassi A, Boldrini A, Dario P. An active one-lobe pulmonary simulator with compliance control for medical training in neonatal mechanical ventilation. J Clini Monit Comput. 2014;28:251–60.CrossRef Baldoli I, Tognarelli S, Cecchi F, Scaramuzzo RT, Ciantelli M, Gentile M, Cuttano A, Laschi C, Menciassi A, Boldrini A, Dario P. An active one-lobe pulmonary simulator with compliance control for medical training in neonatal mechanical ventilation. J Clini Monit Comput. 2014;28:251–60.CrossRef
Metadaten
Titel
Journal of clinical monitoring and computing 2014 end of year summary: respiration
verfasst von
D. S. Karbing
S. E. Rees
M. B. Jaffe
Publikationsdatum
01.04.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 2/2015
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9676-9

Weitere Artikel der Ausgabe 2/2015

Journal of Clinical Monitoring and Computing 2/2015 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.