Kinematics of mobile-bearing unicompartmental knee arthroplasty compared to native: results from an in vitro study

verfasst von: Geert Peersman, Josh Slane, Philippe Vuylsteke, Susanne Fuchs-Winkelmann, Philipp Dworschak, Thomas Heyse, Lennart Scheys

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Fixed-bearing unicompartmental knee arthroplasty (UKA) closely replicates native knee kinematics. As few studies have assessed kinematics following mobile-bearing (MB) UKA, the current study aimed to investigate whether MB UKA preserves natural knee kinematics.

Materials and methods

Seven fresh-frozen full-leg cadaver specimens were prepared and mounted in a kinematic rig that allowed all degrees of freedom at the knee. Three motion patterns, passive flexion–extension (0°–110° flexion), open-chain extension (5°–70° flexion) and squatting (30°–100° flexion), were performed pre- and post-implantation of a medial MB UKA and compared in terms of rotational and translational knee joint kinematics in the different anatomical planes, respectively.

Results

In terms of frontal plane rotational kinematics, MB UKA specimens were in a more valgus orientation for all motion patterns. In the axial plane, internal rotation of the tibia before and after UKA was consistent, regardless of motion task, with no significant differences. In terms of frontal plane, i.e., inferior–superior, translations, the FMCC was significantly higher in UKA knees in all flexion angles and motor tasks, except in early flexion during passive motion. In terms of axial plane, i.e., anteroposterior (AP), translations, during open-chain activities, the femoral medial condyle center (FMCC) tended to be more posterior following UKA relative to the native knee in mid-flexion and above. AP excursions of the FMCC were small in all tested motions, however. There was substantial AP translation of the femoral lateral condyle center during passive motion before and after UKA, which was significantly different for flexion angles > 38°.

Conclusions

Our study data demonstrate that the kinematics of the unloaded knee following MB UKA closely resemble those of the native knee while relative medial overstuffing with UKA will result in the joint being more valgus. However, replacing the conforming and rigidly fixed medial meniscus with a mobile inlay may successfully prevent aberrant posterior translation of the medial femoral compartment during passive motion and squatting motion.
Literatur
1.
Zurück zum Zitat Liddle AD, Pandit H, Judge A, Murray DW (2015) Patient-reported outcomes after total and unicompartmental knee arthroplasty: a study of 14,076 matched patients from the National Joint Registry for England and Wales. Bone Jt J 97-B(6):793–801CrossRef Liddle AD, Pandit H, Judge A, Murray DW (2015) Patient-reported outcomes after total and unicompartmental knee arthroplasty: a study of 14,076 matched patients from the National Joint Registry for England and Wales. Bone Jt J 97-B(6):793–801CrossRef
2.
Zurück zum Zitat Wiik AV, Aqil A, Tankard S, Amis AA, Cobb JP (2015) Downhill walking gait pattern discriminates between types of knee arthroplasty: improved physiological knee functionality in UKA versus TKA. Knee Surg Sports Traumatol Arthrosc 23(6):1748–1755CrossRefPubMed Wiik AV, Aqil A, Tankard S, Amis AA, Cobb JP (2015) Downhill walking gait pattern discriminates between types of knee arthroplasty: improved physiological knee functionality in UKA versus TKA. Knee Surg Sports Traumatol Arthrosc 23(6):1748–1755CrossRefPubMed
3.
Zurück zum Zitat Catani F, Benedetti M, Bianchi L, Marchionni V, Giannini S, Leardini A (2012) Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs. Knee Surg Sports Traumatol Arthrosc 20(6):1042–1048CrossRefPubMed Catani F, Benedetti M, Bianchi L, Marchionni V, Giannini S, Leardini A (2012) Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs. Knee Surg Sports Traumatol Arthrosc 20(6):1042–1048CrossRefPubMed
4.
Zurück zum Zitat Becker R, Mauer C, Starke C, Brosz M, Zantop T, Lohmann CH, Schulze M (2013) Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system. Knee Surg Sports Traumatol Arthrosc 21(11):2427–2432CrossRefPubMed Becker R, Mauer C, Starke C, Brosz M, Zantop T, Lohmann CH, Schulze M (2013) Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system. Knee Surg Sports Traumatol Arthrosc 21(11):2427–2432CrossRefPubMed
5.
Zurück zum Zitat Heyse TJ, El-Zayat BF, De Corte R, Chevalier Y, Scheys L, Innocenti B, Fuchs-Winkelmann S, Labey L (2014) UKA closely preserves natural knee kinematics in vitro. Knee Surg Sports Traumatol Arthrosc 22(8):1902–1910CrossRefPubMed Heyse TJ, El-Zayat BF, De Corte R, Chevalier Y, Scheys L, Innocenti B, Fuchs-Winkelmann S, Labey L (2014) UKA closely preserves natural knee kinematics in vitro. Knee Surg Sports Traumatol Arthrosc 22(8):1902–1910CrossRefPubMed
6.
Zurück zum Zitat Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Matsueda M, Koga Y, Omori G, Endo N (2014) Kinematics of the knee after unicompartmental arthroplasty is not the same as normal and is similar to the kinematics of the knee with osteoarthritis. Knee Surg Sports Traumatol Arthrosc 22(8):1911–1917CrossRefPubMed Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Matsueda M, Koga Y, Omori G, Endo N (2014) Kinematics of the knee after unicompartmental arthroplasty is not the same as normal and is similar to the kinematics of the knee with osteoarthritis. Knee Surg Sports Traumatol Arthrosc 22(8):1911–1917CrossRefPubMed
7.
Zurück zum Zitat Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Koga Y, Yamagiwa H, Omori G, Endo N (2013) In vivo pre- and postoperative three-dimensional knee kinematics in unicompartmental knee arthroplasty. J Orthop Sci 18(1):54–60CrossRefPubMed Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Koga Y, Yamagiwa H, Omori G, Endo N (2013) In vivo pre- and postoperative three-dimensional knee kinematics in unicompartmental knee arthroplasty. J Orthop Sci 18(1):54–60CrossRefPubMed
8.
Zurück zum Zitat Emerson RJ, Hansborough T, Reitman R, Rosenfeldt W, Higgins L (2002) Comparison of a mobile with a fixed-bearing unicompartmental knee implant. Clin Orthop Relat Res 404:62–70CrossRef Emerson RJ, Hansborough T, Reitman R, Rosenfeldt W, Higgins L (2002) Comparison of a mobile with a fixed-bearing unicompartmental knee implant. Clin Orthop Relat Res 404:62–70CrossRef
9.
Zurück zum Zitat Smith T, Hing C, Davies L, Donell S (2009) Fixed versus mobile bearing unicompartmental knee replacement: a meta-analysis. Orthop Traumatol Surg Res 95(8):599–605CrossRefPubMed Smith T, Hing C, Davies L, Donell S (2009) Fixed versus mobile bearing unicompartmental knee replacement: a meta-analysis. Orthop Traumatol Surg Res 95(8):599–605CrossRefPubMed
10.
Zurück zum Zitat Ettinger M, Zoch JM, Becher C, Hurschler C, Stukenborg-Colsman C, Claassen L, Ostermeier S, Calliess T (2015) In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplasty. Arch Orthop Trauma Surg 135(6):871–877CrossRefPubMed Ettinger M, Zoch JM, Becher C, Hurschler C, Stukenborg-Colsman C, Claassen L, Ostermeier S, Calliess T (2015) In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplasty. Arch Orthop Trauma Surg 135(6):871–877CrossRefPubMed
11.
Zurück zum Zitat Walker T, Heinemann P, Bruckner T, Streit MR, Kinkel S, Gotterbarm T (2017) The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position. Arch Orthop Trauma Surg 137(7):895–902CrossRefPubMed Walker T, Heinemann P, Bruckner T, Streit MR, Kinkel S, Gotterbarm T (2017) The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position. Arch Orthop Trauma Surg 137(7):895–902CrossRefPubMed
12.
Zurück zum Zitat Gleeson R, Evans R, Ackroyd C, Webb J, Newman J (2004) Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study. Knee 11(5):379–384CrossRefPubMed Gleeson R, Evans R, Ackroyd C, Webb J, Newman J (2004) Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study. Knee 11(5):379–384CrossRefPubMed
13.
Zurück zum Zitat Li M, Yao F, Joss B, Ioppolo J, Nivbrant B, Wood D (2006) Mobile vs. fixed bearing unicondylar knee arthroplasty: a randomized study on short term clinical outcomes and knee kinematics. Knee 13(5):365–370CrossRefPubMed Li M, Yao F, Joss B, Ioppolo J, Nivbrant B, Wood D (2006) Mobile vs. fixed bearing unicondylar knee arthroplasty: a randomized study on short term clinical outcomes and knee kinematics. Knee 13(5):365–370CrossRefPubMed
14.
Zurück zum Zitat Suzuki T, Ryu K, Kojima K, Iriuchishima T, Saito S, Nagaoka M, Tokuhashi Y (2015) Evaluation of spacer block technique using tensor device in unicompartmental knee arthroplasty. Arch Orthop Trauma Surg 135(7):1011–1016CrossRefPubMed Suzuki T, Ryu K, Kojima K, Iriuchishima T, Saito S, Nagaoka M, Tokuhashi Y (2015) Evaluation of spacer block technique using tensor device in unicompartmental knee arthroplasty. Arch Orthop Trauma Surg 135(7):1011–1016CrossRefPubMed
15.
Zurück zum Zitat Victor J, Van Glabbeek F, Vander Sloten J, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Jt Surg Am 91(Suppl 6):150–163CrossRef Victor J, Van Glabbeek F, Vander Sloten J, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Jt Surg Am 91(Suppl 6):150–163CrossRef
16.
Zurück zum Zitat Brimacombe JM, Wilson DR, Hodgson AJ, Ho KC, Anglin C (2009) Effect of calibration method on Tekscan sensor accuracy. J Biomech Eng 131(3):034503CrossRefPubMed Brimacombe JM, Wilson DR, Hodgson AJ, Ho KC, Anglin C (2009) Effect of calibration method on Tekscan sensor accuracy. J Biomech Eng 131(3):034503CrossRefPubMed
17.
Zurück zum Zitat Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105(2):136–144CrossRefPubMed Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105(2):136–144CrossRefPubMed
18.
Zurück zum Zitat LaPrade RF, Engebretsen AH, Ly TV, Johansen S, Wentorf FA, Engebretsen L (2007) The anatomy of the medial part of the knee. J Bone Jt Surg Am 89(9):2000–2010 LaPrade RF, Engebretsen AH, Ly TV, Johansen S, Wentorf FA, Engebretsen L (2007) The anatomy of the medial part of the knee. J Bone Jt Surg Am 89(9):2000–2010
19.
Zurück zum Zitat Heyse TJ, El-Zayat BF, De Corte R, Scheys L, Chevalier Y, Fuchs-Winkelmann S, Labey L (2014) Biomechanics of medial unicondylar in combination with patellofemoral knee arthroplasty. Knee 21(Suppl 1):S3–S9CrossRefPubMed Heyse TJ, El-Zayat BF, De Corte R, Scheys L, Chevalier Y, Fuchs-Winkelmann S, Labey L (2014) Biomechanics of medial unicondylar in combination with patellofemoral knee arthroplasty. Knee 21(Suppl 1):S3–S9CrossRefPubMed
20.
Zurück zum Zitat Heyse TJ, El-Zayat BF, De Corte R, Scheys L, Chevalier Y, Fuchs-Winkelmann S, Labey L (2016) Balancing UKA: overstuffing leads to high medial collateral ligament strains. Knee Surg Sports Traumatol Arthrosc 24(10):3218–3228CrossRefPubMed Heyse TJ, El-Zayat BF, De Corte R, Scheys L, Chevalier Y, Fuchs-Winkelmann S, Labey L (2016) Balancing UKA: overstuffing leads to high medial collateral ligament strains. Knee Surg Sports Traumatol Arthrosc 24(10):3218–3228CrossRefPubMed
21.
Zurück zum Zitat Heyse TJ, Tucker SM, Rajak Y, Kia M, Lipman JD, Imhauser CW, Westrich GH (2015) Frontal plane stability following UKA in a biomechanical study. Arch Orthop Trauma Surg 135(6):857–865CrossRefPubMed Heyse TJ, Tucker SM, Rajak Y, Kia M, Lipman JD, Imhauser CW, Westrich GH (2015) Frontal plane stability following UKA in a biomechanical study. Arch Orthop Trauma Surg 135(6):857–865CrossRefPubMed
22.
Zurück zum Zitat Mundermann A, Dyrby CO, D’Lima DD, Colwell CW Jr, Andriacchi TP (2008) In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. J Orthop Res 26(9):1167–1172CrossRefPubMed Mundermann A, Dyrby CO, D’Lima DD, Colwell CW Jr, Andriacchi TP (2008) In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. J Orthop Res 26(9):1167–1172CrossRefPubMed
23.
Zurück zum Zitat Victor J (2009) A comparative study on the biomechanics of the native human knee joint and total knee arthroplasty. Katholieke Universiteit, Leuven Victor J (2009) A comparative study on the biomechanics of the native human knee joint and total knee arthroplasty. Katholieke Universiteit, Leuven
24.
Zurück zum Zitat Navacchia A, Rullkoetter PJ, Schutz P, List RB, Fitzpatrick CK, Shelburne KB (2016) Subject-specific modeling of muscle force and knee contact in total knee arthroplasty. J Orthop Res 34(9):1576–1587CrossRefPubMedPubMedCentral Navacchia A, Rullkoetter PJ, Schutz P, List RB, Fitzpatrick CK, Shelburne KB (2016) Subject-specific modeling of muscle force and knee contact in total knee arthroplasty. J Orthop Res 34(9):1576–1587CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Patil S, Colwell CW Jr, Ezzet KA, D’Lima DD (2005) Can normal knee kinematics be restored with unicompartmental knee replacement? J Bone Jt Surg Am 87(2):332–338CrossRef Patil S, Colwell CW Jr, Ezzet KA, D’Lima DD (2005) Can normal knee kinematics be restored with unicompartmental knee replacement? J Bone Jt Surg Am 87(2):332–338CrossRef
26.
Zurück zum Zitat Jeong JH, Kang H, Ha YC, Jang EC (2012) Incarceration of a dislocated mobile bearing to the popliteal fossa after unicompartmental knee arthroplasty. J Arthroplast 27(2):323.e325–323.e327CrossRef Jeong JH, Kang H, Ha YC, Jang EC (2012) Incarceration of a dislocated mobile bearing to the popliteal fossa after unicompartmental knee arthroplasty. J Arthroplast 27(2):323.e325–323.e327CrossRef
27.
Zurück zum Zitat Singh VK, Apsingi S, Balakrishnan S, Manjure S (2012) Posterior dislocation of meniscal bearing insert in mobile bearing unicompartmental knee arthroplasty mimicking a Baker cyst. J Arthroplasty 27(3):494.e413–494.e496CrossRef Singh VK, Apsingi S, Balakrishnan S, Manjure S (2012) Posterior dislocation of meniscal bearing insert in mobile bearing unicompartmental knee arthroplasty mimicking a Baker cyst. J Arthroplasty 27(3):494.e413–494.e496CrossRef
28.
Zurück zum Zitat Lee SY, Bae JH, Kim JG, Jang KM, Shon WY, Kim KW, Lim HC (2014) The influence of surgical factors on dislocation of the meniscal bearing after Oxford medial unicompartmental knee replacement: a case–control study. Bone Jt J 96(7):914–922CrossRef Lee SY, Bae JH, Kim JG, Jang KM, Shon WY, Kim KW, Lim HC (2014) The influence of surgical factors on dislocation of the meniscal bearing after Oxford medial unicompartmental knee replacement: a case–control study. Bone Jt J 96(7):914–922CrossRef
29.
Zurück zum Zitat Argenson J, Komistek R, Aubaniac J, Dennis D, Northcut E, Anderson D, Agostini S (2002) In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplast 17(8):1049–1054CrossRef Argenson J, Komistek R, Aubaniac J, Dennis D, Northcut E, Anderson D, Agostini S (2002) In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplast 17(8):1049–1054CrossRef
Metadaten
Titel
Kinematics of mobile-bearing unicompartmental knee arthroplasty compared to native: results from an in vitro study
verfasst von
Geert Peersman
Josh Slane
Philippe Vuylsteke
Susanne Fuchs-Winkelmann
Philipp Dworschak
Thomas Heyse
Lennart Scheys
Publikationsdatum
21.09.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 11/2017
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2794-8

Weitere Artikel der Ausgabe 11/2017

Archives of Orthopaedic and Trauma Surgery 11/2017 Zur Ausgabe

Abstracts

Abstracts

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.