Skip to main content
Erschienen in: European Radiology 12/2018

12.06.2018 | Contrast Media

Large-volume iodinated contrast medium extravasation: low frequency and good outcome after conservative management in a single-centre cohort of more than 67,000 patients

verfasst von: Chih-Hsiang Ko, Shee Yen Tay, Hsiu-Chin Chang, Wing P. Chan

Erschienen in: European Radiology | Ausgabe 12/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Our aim was to retrospectively investigate the frequency and outcome of large-volume iodinated contrast medium (CM) extravasation in our institution and to compare our management protocol to current practice.

Methods

Institutional review board approval was obtained, and informed consent was waived because the study was retrospective. From January 2008 to September 2016, radiological examinations with intravenous non-ionic iodinated CM administration were performed in 67,129 patients. Contrast medium extravasation events on CT scans and intravenous pyelograms but not on angiograms were included. All data were collected prospectively and stratified according to age, injection method (manual vs auto-injection), prevention of extravasation by various means (including intercom alarm), management of extravasation (routine application of silver sulfadiazine ointment, clobetasol propionate cream, and damp gauze at room temperature), etc.

Results

The incidence of large-volume CM extravasation was very low (0.04% [27/67,129] overall; 0.03% related to manual injection [age range, 59-92 years; mean, 75.4 years], and 0.045% related to auto-injection [age range, 36-86 years; mean, 65.8 years]). The CM extravasation volume in majority of patients was 20–40 ml in 5 of 9 patients (55.6%) in the manual injection group and 14 of 18 (77.8%) in the auto-injection group. Swelling and pain were the most common symptoms. No patient developed severe signs or needed surgical intervention.

Conclusions

Results show a very low incidence of large-volume CM extravasation without severe complications or sequelae. The casual effect between our protocols and good outcome cannot be scrutinised thoroughly because the study lacks a control group and is retrospective.

Key Points

• The incidence of large-volume contrast medium extravasation (≥20 ml) was 0.04%.
• No patient needed surgical intervention, and most recovered within 7 days.
• Each element of our management protocol contributed to good outcome.
Literatur
2.
Zurück zum Zitat Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef
3.
Zurück zum Zitat Wang CL, Cohan RH, Ellis JH, Caoili EM, Wang G, Francis IR (2007) Frequency, management, and outcome of extravasation of non-ionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef Wang CL, Cohan RH, Ellis JH, Caoili EM, Wang G, Francis IR (2007) Frequency, management, and outcome of extravasation of non-ionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef
4.
Zurück zum Zitat Schaverien MV, Evison D, McCulley SJ (2008) Management of large volume CT contrast medium extravasation injury: technical refinement and literature review. J Plast Reconstr Aesthet Surg 61:562–565CrossRef Schaverien MV, Evison D, McCulley SJ (2008) Management of large volume CT contrast medium extravasation injury: technical refinement and literature review. J Plast Reconstr Aesthet Surg 61:562–565CrossRef
5.
Zurück zum Zitat Bellin M, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef Bellin M, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef
6.
Zurück zum Zitat Ding S, Meystre NR, Campeanu C, Gullo G (2017) Contrast media extravasations among in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions. JBI Database System Rev Implement Rep 16(1):87–116CrossRef Ding S, Meystre NR, Campeanu C, Gullo G (2017) Contrast media extravasations among in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions. JBI Database System Rev Implement Rep 16(1):87–116CrossRef
7.
Zurück zum Zitat Sonis JD, Gottumukkala RV, Glover M 4th et al (2017) Implications of iodinated contrast media extravasation in the emergency department. Am J Emerg Med 36(2):294–296CrossRef Sonis JD, Gottumukkala RV, Glover M 4th et al (2017) Implications of iodinated contrast media extravasation in the emergency department. Am J Emerg Med 36(2):294–296CrossRef
9.
Zurück zum Zitat Cohan RH, Dunnick NR, Leder RA, Baker ME (1990) Extravasation of nonionic radiologic contrast media: efficacy of conservative treatment. Radiology 176(1):65–67CrossRef Cohan RH, Dunnick NR, Leder RA, Baker ME (1990) Extravasation of nonionic radiologic contrast media: efficacy of conservative treatment. Radiology 176(1):65–67CrossRef
10.
Zurück zum Zitat Tonolini M, Campar IA, Bianco R (2012) Extravasation of radiographic contrast media: Prevention, diagnosis, and treatment. Curr Probl Diagn Radiol 41:52–55CrossRef Tonolini M, Campar IA, Bianco R (2012) Extravasation of radiographic contrast media: Prevention, diagnosis, and treatment. Curr Probl Diagn Radiol 41:52–55CrossRef
11.
Zurück zum Zitat Nicola R, Shaqdan KW, Aran S, Prabhakar AM, Singh AK, Abujudeh HH (2016) Contrast media extravasation of computed tomography and magnetic resonance imaging: Management guidelines for the radiologist. Curr Probl Diagn Radiol 45:161–164CrossRef Nicola R, Shaqdan KW, Aran S, Prabhakar AM, Singh AK, Abujudeh HH (2016) Contrast media extravasation of computed tomography and magnetic resonance imaging: Management guidelines for the radiologist. Curr Probl Diagn Radiol 45:161–164CrossRef
12.
Zurück zum Zitat Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiographics 35:1738CrossRef Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiographics 35:1738CrossRef
13.
Zurück zum Zitat Hastings-Tolsma TM, Yucha CB, Tompkins J, Robson L, Szeverenyi N (1993) Effect of warm and cold applications on the resolution of IV infiltrations. Res Nurs Health 16:171–178CrossRef Hastings-Tolsma TM, Yucha CB, Tompkins J, Robson L, Szeverenyi N (1993) Effect of warm and cold applications on the resolution of IV infiltrations. Res Nurs Health 16:171–178CrossRef
14.
Zurück zum Zitat Sum W, Ridley LJ (2006) Recognition and management of contrast media extravasation. Australas Radiol 50:549–552CrossRef Sum W, Ridley LJ (2006) Recognition and management of contrast media extravasation. Australas Radiol 50:549–552CrossRef
15.
Zurück zum Zitat Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: Recognition, prevention, and treatment. Radiology 200:593–604CrossRef Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: Recognition, prevention, and treatment. Radiology 200:593–604CrossRef
16.
Zurück zum Zitat Heckler FR (1989) Current thoughts on extravasation injuries. Clin Plast Surg 16:557–563PubMed Heckler FR (1989) Current thoughts on extravasation injuries. Clin Plast Surg 16:557–563PubMed
19.
Metadaten
Titel
Large-volume iodinated contrast medium extravasation: low frequency and good outcome after conservative management in a single-centre cohort of more than 67,000 patients
verfasst von
Chih-Hsiang Ko
Shee Yen Tay
Hsiu-Chin Chang
Wing P. Chan
Publikationsdatum
12.06.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 12/2018
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5514-z

Weitere Artikel der Ausgabe 12/2018

European Radiology 12/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.