Skip to main content
Erschienen in: Current Anesthesiology Reports 2/2018

01.06.2018 | Advances in Monitoring for Anesthesia (LAH Critchley, Section Editor)

Latest Advances in Cardiac Output Monitoring from High-Definition Impedance Cardiography

verfasst von: Jean J. Bour

Erschienen in: Current Anesthesiology Reports | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose of Review

Cardiac output (CO) and hemodynamic parameters, and specifically the noninvasive approach to their measurement, have been the subject of continuous technological developments and lengthy debates. The challenge remains to measure these parameters in a user friendly and cost-effective way, without compromising accuracy and with few limitations in the real clinical environment.

Recent Findings

The industry might have solved the issue with the latest development of thoracic bioimpedance, called high-definition impedance cardiography (HD-ICG) and based on the direct analysis of morphology of the heart impedance signals. It may offer improvements in accuracy, inter-operator reproducibility, sensitivity, and parameters management, and also simplifies the understanding of the etiology of cardiac dysfunctions.

Summary

HD-ICG might have the potential to make hemodynamic measurements in anesthesia come of age and become a clinical standard.
Literatur
1.
Zurück zum Zitat Kedrov AA. An attempt to quantify assessment of the central and peripheral circulation by electrometrical method. Klin Med. 1948;26:32–51. (in Russian language) Kedrov AA. An attempt to quantify assessment of the central and peripheral circulation by electrometrical method. Klin Med. 1948;26:32–51. (in Russian language)
2.
Zurück zum Zitat Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B, et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol. 2000;82(4):313–20.CrossRef Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B, et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol. 2000;82(4):313–20.CrossRef
4.
Zurück zum Zitat Tan KH, Lai FO, Hwang NC. Measurement of cardiac output using physio flow with different positions of electrode placement. Singap Med J. 2006;47(11):967–70. Tan KH, Lai FO, Hwang NC. Measurement of cardiac output using physio flow with different positions of electrode placement. Singap Med J. 2006;47(11):967–70.
6.
Zurück zum Zitat Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.CrossRef Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.CrossRef
8.
Zurück zum Zitat Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B, et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol. 2000;82(4):313–20.CrossRef Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B, et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol. 2000;82(4):313–20.CrossRef
9.
Zurück zum Zitat • Antoine Legendre D, Bonnet LB. Reliability of peak exercise stroke volume assessment by impedance cardiography in patients with residual right outflow tract lesions after congenital heart disease repair. https://doi.org/10.1007/s00246-017-1725-3. First Online: 25 September 2017. This article illustrates the reproducibility of HD ICG and determines the threshold for significant changes in SV. • Antoine Legendre D, Bonnet LB. Reliability of peak exercise stroke volume assessment by impedance cardiography in patients with residual right outflow tract lesions after congenital heart disease repair. https://​doi.​org/​10.​1007/​s00246-017-1725-3. First Online: 25 September 2017. This article illustrates the reproducibility of HD ICG and determines the threshold for significant changes in SV.
10.
Zurück zum Zitat • Gratz I, Deal E, Spitz F, Allen E, Pukenas E. Continuous cardiac output monitoring during major intra-abdominal surgery: physioflow signal-morphology impedance cardiography vs. flotrac/vigileo vs. central venous oxygen saturation, Abstract presented at the ASA 2012 annual meeting. This study illustrates the superiority of HD ICG as compared to pulse contour technologies. • Gratz I, Deal E, Spitz F, Allen E, Pukenas E. Continuous cardiac output monitoring during major intra-abdominal surgery: physioflow signal-morphology impedance cardiography vs. flotrac/vigileo vs. central venous oxygen saturation, Abstract presented at the ASA 2012 annual meeting. This study illustrates the superiority of HD ICG as compared to pulse contour technologies.
11.
Zurück zum Zitat • Heshmati N Jr, Marguerite S, Jazaerli L Jr, Bongarzone C Jr, Thiranos J-C, Meyer N, et al. Stroke volume variation measured by impedance cardiography during passive leg raising to assess fluid responsiveness after cardiac surgery. Abstract presented at the ASA annual meeting 2013. This study illustrates the ability of HD ICG to predict fluid responsiveness. • Heshmati N Jr, Marguerite S, Jazaerli L Jr, Bongarzone C Jr, Thiranos J-C, Meyer N, et al. Stroke volume variation measured by impedance cardiography during passive leg raising to assess fluid responsiveness after cardiac surgery. Abstract presented at the ASA annual meeting 2013. This study illustrates the ability of HD ICG to predict fluid responsiveness.
12.
Zurück zum Zitat You-Ten KE, Terblanche N, Borges B, Carvalho J. Hypotension during cesarean delivery: role of impedance cardiography. Can J Anaesth. 2008;55(Supplement 1):4755741–2. Cite asCrossRef You-Ten KE, Terblanche N, Borges B, Carvalho J. Hypotension during cesarean delivery: role of impedance cardiography. Can J Anaesth. 2008;55(Supplement 1):4755741–2. Cite asCrossRef
15.
Zurück zum Zitat Hofer CK, Cannesson M. Monitoring fluid responsiveness. Acta Anaesthesiol Taiwanica. 2011;49(2):59–65.CrossRef Hofer CK, Cannesson M. Monitoring fluid responsiveness. Acta Anaesthesiol Taiwanica. 2011;49(2):59–65.CrossRef
16.
Zurück zum Zitat Rose DK, Cohen MM, DeBoer DP. Cardiovascular events in the postanesthesia care unit: contribution of risk factors. Anesthesiology. 1996;84(4):772–81.CrossRef Rose DK, Cohen MM, DeBoer DP. Cardiovascular events in the postanesthesia care unit: contribution of risk factors. Anesthesiology. 1996;84(4):772–81.CrossRef
17.
Zurück zum Zitat Smith DH, Johnson ES, Thorp ML, Yang X, Petrik A, Platt RW, et al. Predicting poor outcomes in heart failure. Perm J. 2011 Fall;15(4):4–11. Published online Fall 2011. Smith DH, Johnson ES, Thorp ML, Yang X, Petrik A, Platt RW, et al. Predicting poor outcomes in heart failure. Perm J. 2011 Fall;15(4):4–11. Published online Fall 2011.
19.
Zurück zum Zitat Epstein SK, Freeman RB, Khayat A, Unterborn JN, Pratt DS, Kaplan MM. Aerobic capacity is associated with 100-day outcome after hepatic transplantation. Liver Transpl. 2004;10:418–24.CrossRef Epstein SK, Freeman RB, Khayat A, Unterborn JN, Pratt DS, Kaplan MM. Aerobic capacity is associated with 100-day outcome after hepatic transplantation. Liver Transpl. 2004;10:418–24.CrossRef
20.
Zurück zum Zitat Guazzi M, Arena R, Halle M, Piepoli MF, Myers J, Lavie CJ. EACPR/AHA SCIENTIFIC STATEMENT. 2016 Focused update: clinical recommendations for cardiopulmonary exercise testing data assessment in specific patient populations. Circulation. 2016:CIR.0000000000000406. https://doi.org/10.1161/CIR.0000000000000406. Originally published May 2, 2016 Guazzi M, Arena R, Halle M, Piepoli MF, Myers J, Lavie CJ. EACPR/AHA SCIENTIFIC STATEMENT. 2016 Focused update: clinical recommendations for cardiopulmonary exercise testing data assessment in specific patient populations. Circulation. 2016:CIR.0000000000000406. https://​doi.​org/​10.​1161/​CIR.​0000000000000406​. Originally published May 2, 2016
21.
Zurück zum Zitat •• Myers J, Wong M, Adhikarla C, Boga M, Challa S, Abella J, et al. High predictive value of HD ICG in heart failure. Cardiopulmonary and noninvasive hemodynamic responses to exercise predict outcomes in heart failure. J Card Fail. 2013;19(2):101–7. https://doi.org/10.1016/j.cardfail.2012.11.010. This article illustrates the high predictive value of HD ICG during exercise testing in heart failure CrossRefPubMed •• Myers J, Wong M, Adhikarla C, Boga M, Challa S, Abella J, et al. High predictive value of HD ICG in heart failure. Cardiopulmonary and noninvasive hemodynamic responses to exercise predict outcomes in heart failure. J Card Fail. 2013;19(2):101–7. https://​doi.​org/​10.​1016/​j.​cardfail.​2012.​11.​010. This article illustrates the high predictive value of HD ICG during exercise testing in heart failure CrossRefPubMed
23.
Zurück zum Zitat Suaya JA, Stason WB, Ades PA, Normand SL, Shepard DS. Cardiac rehabilitation and survival in older coronary patients. J Am Coll Cardiol. 2009;54:25–33.CrossRef Suaya JA, Stason WB, Ades PA, Normand SL, Shepard DS. Cardiac rehabilitation and survival in older coronary patients. J Am Coll Cardiol. 2009;54:25–33.CrossRef
24.
Zurück zum Zitat Lai C, Chang W, Chiang K, Chu H. Associations between G tolerance and changes of stroke volume, heart rate, and cardiac output in operating anti-G straining maneuver. Aerosp Med Hum Perform. 2016;87(1):315. Lai C, Chang W, Chiang K, Chu H. Associations between G tolerance and changes of stroke volume, heart rate, and cardiac output in operating anti-G straining maneuver. Aerosp Med Hum Perform. 2016;87(1):315.
Metadaten
Titel
Latest Advances in Cardiac Output Monitoring from High-Definition Impedance Cardiography
verfasst von
Jean J. Bour
Publikationsdatum
01.06.2018
Verlag
Springer US
Erschienen in
Current Anesthesiology Reports / Ausgabe 2/2018
Elektronische ISSN: 2167-6275
DOI
https://doi.org/10.1007/s40140-018-0271-8

Weitere Artikel der Ausgabe 2/2018

Current Anesthesiology Reports 2/2018 Zur Ausgabe

Transplantation Anesthesia (KG Belani, Section Editor)

Issues in Pediatric Liver Transplantation

Neuromuscular Blockade (GS Murphy, Section Editor)

Neuromuscular Blocking Drugs and Postoperative Pulmonary Complications

Geriatric Anesthesia (S Akhtar, Section Editor)

Perioperative Outcome in Geriatric Patients

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.