Skip to main content
Erschienen in: Archives of Gynecology and Obstetrics 2/2016

28.05.2016 | Images in Obstetrics and Gynecology

LECANDUS study (LEsion CANdidate Detection in UltraSound Data): evaluation of image analysis algorithms for breast lesion detection in volume ultrasound data

verfasst von: Michael Golatta, Désirée Zeegers, Konstantinos Filippatos, Leah-Larissa Binder, Alexander Scharf, Geraldine Rauch, Joachim Rom, Florian Schütz, Christof Sohn, Joerg Heil

Erschienen in: Archives of Gynecology and Obstetrics | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study aims at developing and evaluating a prototype of a lesion candidate detection algorithm for a 3D-US computer-aided diagnosis (CAD) system.

Methods

Additionally, to routine imaging, automated breast volume scans (ABVS) were performed on 63 patients. All ABVS exams were analyzed and annotated before the evaluation with different algorithm blob detectors characterized by different blob-radiuses, voxel-sizes and the quantiles of blob filter responses to find lesion candidates. Lesions found in candidates were compared to the prior annotations.

Results

All histologically proven lesions were detected with at least one algorithm. The algorithm with optimal sensitivity detected all cancers (sensitivity = 100 %) with a very low positive predictive value due to a high false-positive rate.

Conclusions

ABVS is a new technology which can be analyzed by a CAD software. Using different algorithms, lesions can be detected with a very high and accurate sensitivity. Further research for feature extraction and lesion classification is needed aiming at reducing the false-positive hits.
Literatur
1.
Zurück zum Zitat Zonderland HM, Coerkamp EG, Hermans J, van de Vijver MJ, van Voorthuisen AE (1999) Diagnosis of breast cancer: contribution of US as an adjunct to mammography. Radiology 213(2):413–422CrossRefPubMed Zonderland HM, Coerkamp EG, Hermans J, van de Vijver MJ, van Voorthuisen AE (1999) Diagnosis of breast cancer: contribution of US as an adjunct to mammography. Radiology 213(2):413–422CrossRefPubMed
3.
Zurück zum Zitat Ikedo Y, Morita T, Fukuoka D, Hara T, Lee G, Fujita H, Takada E, Endo T (2009) Automated analysis of breast parenchymal patterns in whole breast ultrasound images: preliminary experience. Int J Comput Assist Radiol Surg 4(3):299–306. doi:10.1007/s11548-009-0295-0 CrossRefPubMed Ikedo Y, Morita T, Fukuoka D, Hara T, Lee G, Fujita H, Takada E, Endo T (2009) Automated analysis of breast parenchymal patterns in whole breast ultrasound images: preliminary experience. Int J Comput Assist Radiol Surg 4(3):299–306. doi:10.​1007/​s11548-009-0295-0 CrossRefPubMed
5.
Zurück zum Zitat Golatta M, Franz D, Harcos A, Junkermann H, Rauch G, Scharf A, Schuetz F, Sohn C, Heil J (2013) Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results. Eur J Radiol 82(8):e332–e336. doi:10.1016/j.ejrad.2013.03.005 CrossRefPubMed Golatta M, Franz D, Harcos A, Junkermann H, Rauch G, Scharf A, Schuetz F, Sohn C, Heil J (2013) Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results. Eur J Radiol 82(8):e332–e336. doi:10.​1016/​j.​ejrad.​2013.​03.​005 CrossRefPubMed
6.
Zurück zum Zitat Wojcinski S, Farrokh A, Hille U, Wiskirchen J, Gyapong S, Soliman AA, Degenhardt F, Hillemanns P (2011) The Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. Int J Womens Health 3:337–346. doi:10.2147/ijwh.s23918 CrossRefPubMedPubMedCentral Wojcinski S, Farrokh A, Hille U, Wiskirchen J, Gyapong S, Soliman AA, Degenhardt F, Hillemanns P (2011) The Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. Int J Womens Health 3:337–346. doi:10.​2147/​ijwh.​s23918 CrossRefPubMedPubMedCentral
8.
9.
Zurück zum Zitat Chabi ML, Borget I, Ardiles R, Aboud G, Boussouar S, Vilar V, Dromain C, Balleyguier C (2012) Evaluation of the accuracy of a computer-aided diagnosis (CAD) system in breast ultrasound according to the radiologist’s experience. Acad Radiol 19(3):311–319. doi:10.1016/j.acra.2011.10.023 CrossRefPubMed Chabi ML, Borget I, Ardiles R, Aboud G, Boussouar S, Vilar V, Dromain C, Balleyguier C (2012) Evaluation of the accuracy of a computer-aided diagnosis (CAD) system in breast ultrasound according to the radiologist’s experience. Acad Radiol 19(3):311–319. doi:10.​1016/​j.​acra.​2011.​10.​023 CrossRefPubMed
11.
Zurück zum Zitat Mendelson E, Baum J, Berg W (2003) Breast imaging reporting and data system: ACR BI-RADS—breast imaging atlas. In: BI-RADS: Ultrasound Reston. American College of Radiology, VA Mendelson E, Baum J, Berg W (2003) Breast imaging reporting and data system: ACR BI-RADS—breast imaging atlas. In: BI-RADS: Ultrasound Reston. American College of Radiology, VA
13.
Zurück zum Zitat Sato Y, Nakajima S, Shiraga N, Atsumi H, Yoshida S, Koller T, Gerig G, Kikinis R (1998) Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. Med Image Anal 2(2):143–168CrossRefPubMed Sato Y, Nakajima S, Shiraga N, Atsumi H, Yoshida S, Koller T, Gerig G, Kikinis R (1998) Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. Med Image Anal 2(2):143–168CrossRefPubMed
15.
Zurück zum Zitat Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. Lect Notes Comput Sci 1496:130–137CrossRef Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. Lect Notes Comput Sci 1496:130–137CrossRef
17.
Zurück zum Zitat Li Q, Sone S, Doi K (2003) Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans. Med Phys 30(8):2040–2051CrossRefPubMed Li Q, Sone S, Doi K (2003) Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans. Med Phys 30(8):2040–2051CrossRefPubMed
19.
Zurück zum Zitat Yap MH, Edirisinghe EA, Bez HE (2008) A novel algorithm for initial lesion detection in ultrasound breast images. J Appl Clin Med Phys 9(4):2741CrossRefPubMed Yap MH, Edirisinghe EA, Bez HE (2008) A novel algorithm for initial lesion detection in ultrasound breast images. J Appl Clin Med Phys 9(4):2741CrossRefPubMed
20.
Zurück zum Zitat Ikedo Y, Fukuoka D, Hara T, Fujita H, Takada E, Endo T, Morita T (2007) Development of a fully automatic scheme for detection of masses in whole breast ultrasound images. Med Phys 34(11):4378–4388CrossRefPubMed Ikedo Y, Fukuoka D, Hara T, Fujita H, Takada E, Endo T, Morita T (2007) Development of a fully automatic scheme for detection of masses in whole breast ultrasound images. Med Phys 34(11):4378–4388CrossRefPubMed
Metadaten
Titel
LECANDUS study (LEsion CANdidate Detection in UltraSound Data): evaluation of image analysis algorithms for breast lesion detection in volume ultrasound data
verfasst von
Michael Golatta
Désirée Zeegers
Konstantinos Filippatos
Leah-Larissa Binder
Alexander Scharf
Geraldine Rauch
Joachim Rom
Florian Schütz
Christof Sohn
Joerg Heil
Publikationsdatum
28.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Gynecology and Obstetrics / Ausgabe 2/2016
Print ISSN: 0932-0067
Elektronische ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-016-4127-5

Weitere Artikel der Ausgabe 2/2016

Archives of Gynecology and Obstetrics 2/2016 Zur Ausgabe

Gynecologic Endocrinology and Reproductive Medicine

Hysteroscopic adhesiolysis: efficacy and safety

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.