Abstract

Introduction

Studies on software accuracy of reformatted panoramic computed tomography (CT) images are scarce.

Objectives

The aim of this study was to evaluate the software accuracy of reformatted panoramic views from cone-beam computed tomography (CBCT).

Methods

Ten dry mandibles were scanned using CBCT with different voxel sizes. Following the reconstruction of panoramic views with three different software, horizontal and vertical linear measurements were performed using the electronic rules of each software. Measurements of the corresponding dry mandibles were taken with a digital caliper and defined as the gold standard.

Results

There were no statistically significant differences in linear distances among the dry mandibles and reformatted panoramic CT views. The relative error ranged from 1.3 to 8.0%, depending on the software and voxel size.

Conclusions

The linear measurements on reformatted panoramic views are reliable.
Zugang erhalten Sie mit:
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103:534–42. CrossRef Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103:534–42. CrossRef
2.
Zurück zum Zitat Kim G, Jung HJ, Lee HJ, Lee JS, Koo S, Chang SH. Accuracy and reliability of length measurements on three-dimensional computed tomography using open-source OsiriX software. J Digit Imaging. 2012;25:486–91. CrossRef Kim G, Jung HJ, Lee HJ, Lee JS, Koo S, Chang SH. Accuracy and reliability of length measurements on three-dimensional computed tomography using open-source OsiriX software. J Digit Imaging. 2012;25:486–91. CrossRef
3.
Zurück zum Zitat Vasconcellos ACRS, Maciel AS, Rubira CMF, Rubira-Bullen IRF, Sarmento VA. Accuracy of linear measurement in computed tomography: a systematic review. Int J Enhanc Res Sci Technol Eng. 2015;4(2):79–88. Vasconcellos ACRS, Maciel AS, Rubira CMF, Rubira-Bullen IRF, Sarmento VA. Accuracy of linear measurement in computed tomography: a systematic review. Int J Enhanc Res Sci Technol Eng. 2015;4(2):79–88.
4.
Zurück zum Zitat Hu KS, Choi DY, Lee WJ, Kim HJ, Jung UW, Kim S. Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers. J Periodontal Implant Sci. 2012;42:39–44. CrossRef Hu KS, Choi DY, Lee WJ, Kim HJ, Jung UW, Kim S. Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers. J Periodontal Implant Sci. 2012;42:39–44. CrossRef
5.
Zurück zum Zitat Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod. 2014;19(5):45–53. CrossRef Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod. 2014;19(5):45–53. CrossRef
6.
Zurück zum Zitat Luo T, Shi C, Zhao X, Zhao Y, Xu J. Automatic synthesis of panoramic radiographs from dental cone beam computed tomography data. PloS One. 2016;11(6):e0156976. CrossRef Luo T, Shi C, Zhao X, Zhao Y, Xu J. Automatic synthesis of panoramic radiographs from dental cone beam computed tomography data. PloS One. 2016;11(6):e0156976. CrossRef
7.
Zurück zum Zitat Barreto MS, Barbosa IS, Ribeiro PML, Araujo TM, Sarmento VA. Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT. Orthod Craniofac Res. 2020;23:223–8. CrossRef Barreto MS, Barbosa IS, Ribeiro PML, Araujo TM, Sarmento VA. Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT. Orthod Craniofac Res. 2020;23:223–8. CrossRef
8.
Zurück zum Zitat Choi JY, et al. Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg. 2002;31:23–322. CrossRef Choi JY, et al. Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg. 2002;31:23–322. CrossRef
9.
Zurück zum Zitat Papakosta TK, Savva AD, Economopoulos TL, Matsopoulos GK, Grohndal HG. An automatic panoramic image reconstruction scheme from dental computed tomography images. Dentomaxillofac Radiol. 2017;46(4):2016–25. CrossRef Papakosta TK, Savva AD, Economopoulos TL, Matsopoulos GK, Grohndal HG. An automatic panoramic image reconstruction scheme from dental computed tomography images. Dentomaxillofac Radiol. 2017;46(4):2016–25. CrossRef
10.
Zurück zum Zitat Ganguly R, Ramesh A, Pagni S. The accuracy of linear measurements of maxillary and mandibular edentolous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions. Imaging Sci Dent. 2016;46(2):93–101. CrossRef Ganguly R, Ramesh A, Pagni S. The accuracy of linear measurements of maxillary and mandibular edentolous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions. Imaging Sci Dent. 2016;46(2):93–101. CrossRef
12.
Zurück zum Zitat Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205–16. CrossRef Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205–16. CrossRef
13.
Zurück zum Zitat Wood R, Sun Z, Chaudhry J, Tee BC, Kim DG, Leblebicioglu B, England G. Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beamcomputed tomography images. Am J Orthod Dentofacial Orthop. 2013;143(3):353–63. CrossRef Wood R, Sun Z, Chaudhry J, Tee BC, Kim DG, Leblebicioglu B, England G. Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beamcomputed tomography images. Am J Orthod Dentofacial Orthop. 2013;143(3):353–63. CrossRef
14.
Zurück zum Zitat Wanzeler AMV. Analysis of free software for computed tomography cone beam of interest to dentists. Rev bras odontol Rio de Janeiro. 2015;72(1/2):51–5. CrossRef Wanzeler AMV. Analysis of free software for computed tomography cone beam of interest to dentists. Rev bras odontol Rio de Janeiro. 2015;72(1/2):51–5. CrossRef
16.
Zurück zum Zitat Menezes CC, Janson G, da Silveira MC, Cambiaghi L, Garib DG. Precision, reproducibility, and accuracy of bone crest level measurements of CBCT crosssections using different resolutions. Angle Orthod. 2016;86(4):535–42 Epub 2015 Oct 21. CrossRef Menezes CC, Janson G, da Silveira MC, Cambiaghi L, Garib DG. Precision, reproducibility, and accuracy of bone crest level measurements of CBCT crosssections using different resolutions. Angle Orthod. 2016;86(4):535–42 Epub 2015 Oct 21. CrossRef
17.
Zurück zum Zitat Hekmatian E, Jafari-Pozve N, Khorrami L. The effect of voxel size on the measurement of mandibular thickness in cone-beam computedtomography. Dent Res J (Isfahan). 2014;11(5):544–8. Hekmatian E, Jafari-Pozve N, Khorrami L. The effect of voxel size on the measurement of mandibular thickness in cone-beam computedtomography. Dent Res J (Isfahan). 2014;11(5):544–8.
18.
Zurück zum Zitat Kamburoğlu K, Ereş G, Akgün C, Yeta EN, Gülen O, Karacaoĝlu F. Effect of voxel size on accuracy of cone beam computed tomography-aided assessment of periodontal furcation involvement. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(5):644–50. CrossRef Kamburoğlu K, Ereş G, Akgün C, Yeta EN, Gülen O, Karacaoĝlu F. Effect of voxel size on accuracy of cone beam computed tomography-aided assessment of periodontal furcation involvement. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(5):644–50. CrossRef
19.
Zurück zum Zitat Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop. 2010;137(16):e1–6. Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop. 2010;137(16):e1–6.
20.
Zurück zum Zitat Waltrick KB, Nunes de Abreu Junior MJ, Corrêa M, Zastrow MD, Dutra VD. Accuracy of linear measurements and visibility of the mandibular canal of cone-beam computed tomography images with different voxel sizes: an in vitro study. J Periodontol. 2013;84:68–77. CrossRef Waltrick KB, Nunes de Abreu Junior MJ, Corrêa M, Zastrow MD, Dutra VD. Accuracy of linear measurements and visibility of the mandibular canal of cone-beam computed tomography images with different voxel sizes: an in vitro study. J Periodontol. 2013;84:68–77. CrossRef
21.
Zurück zum Zitat Shahidi S, Zamiri B, Abolvardi M, Akhlaghian M. Paknahad comparison of dental panoramic radiography and CBCT for measuring vertical bone height in different horizontal locations of posterior mandibular alveolar process. J Dent (Shiraz). 2018;19(2):83–91. Shahidi S, Zamiri B, Abolvardi M, Akhlaghian M. Paknahad comparison of dental panoramic radiography and CBCT for measuring vertical bone height in different horizontal locations of posterior mandibular alveolar process. J Dent (Shiraz). 2018;19(2):83–91.
22.
Zurück zum Zitat Pimentel PA, Bomfim RT, Andrade LCS, Ferraz EG, Lamberti PLR, RubiraBullen IRF, Sarmento VA. Dimensional error of three-dimensional images generated by different software. J Med Eng Technol. 2015;39(8):480–4. CrossRef Pimentel PA, Bomfim RT, Andrade LCS, Ferraz EG, Lamberti PLR, RubiraBullen IRF, Sarmento VA. Dimensional error of three-dimensional images generated by different software. J Med Eng Technol. 2015;39(8):480–4. CrossRef
Metadaten
Titel
Linear measurement accuracy of CBCT panoramic reconstructions: experimental study with dry human mandibles
verfasst von
Viviane de Sousa Moreira Almeida
Rodrigo Tavares Bomfim
Ana Cristina Rosário Sobreira
Inessa da Silva Barbosa
Patricia Miranda Leite-Ribeiro
Izabel Regina Rubira-Bullen
Viviane Almeida Sarmento
Publikationsdatum
16.09.2020
Verlag
Springer Singapore
Erschienen in
Oral Radiology / Ausgabe 3/2021
Print ISSN: 0911-6028
Elektronische ISSN: 1613-9674
DOI
https://doi.org/10.1007/s11282-020-00477-4