Implementation of the Natural Heartbeat Synchronize Control for the Undulation Pump Ventricular Assist Device Using the Inflow Pressure

  • Conference paper

Part of the book series: IFMBE Proceedings ((IFMBE,volume 19))

Abstract

The undulation pump ventricular assist device (UPVAD) is a small implantable ventricular assist device using an undulation pump. The UPVAD can produce not only continuous flow but also pulsatile flow by changing the motor rotational speed of the UPVAD. Because the undulation pump is a volume displacement type pump in which the inflow action and outflow action both start at the same phase, the inflow sucking occurs easily. The purpose of this study is to develop a suitable control method for the UPVAD. The UPVAD inflow cannula equipped with an implantable blood pressure sensor is inserted into the ventricular. Therefore, pressure fluctuation that synchronizes with the natural heartbeat is observed in the inflow cannula. By changing the motor rotational speed that responds to the inflow pressure, the UPVAD can synchronize with the natural heartbeat and the UPVAD can generate either aco-pulse assist flow or a counter pulse assist flow. The newly developed control method exhibited superior characteristics than existing ones due to high immunity against pressure sensor drift. The improved control method is implemented into the microcontroller. The UPVAD generated 5.3 l/min co-pulse assist flow without inflow cannula sucking using this control method. The assist flow can be increased more than 15% with this control method. This control was implemented one-chip microcontroller without extra peripheral device. It can reduce the UPVAD controller size. The UPVAD can generate the suitable assist flow with the developed control method.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Abe Y, Chinzei T, Isoyama T, Ono T, Mabuchi K, Imanishi K, Kouno A, Atsumi K, Fujimasa I, Imachi K (1995) Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump. Artificial Organs 19:691–693

    Google Scholar 

  2. Abe Y, Chinzei T, Isoyama T, Ono T, Mochizuki S, Mabuchi K, Baba K, Matuura H, Sun Y P, Kouno A, Atsumi K, Fujimasa I, Imachi K (1997) Development of the undulation pump total artificial heart. Artificial Organs 21:665–669

    Article  Google Scholar 

  3. Abe Y, Chinzei T, Isoyama T, Ono T, Mochizuki S, Saito I, Guba P, Karita T, Sun Y P, Kouno A, Suzuki T, Baba K, Mabuchi K, Imachi K (1999) Present status of the total artificial heart at the University of Tokyo. Artificial Organs 23:221–228

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Saito, I. et al. (2008). Implementation of the Natural Heartbeat Synchronize Control for the Undulation Pump Ventricular Assist Device Using the Inflow Pressure. In: Peng, Y., Weng, X. (eds) 7th Asian-Pacific Conference on Medical and Biological Engineering. IFMBE Proceedings, vol 19. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79039-6_17

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-79039-6_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-79038-9

  • Online ISBN: 978-3-540-79039-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics