Abstract
In many nuclear medicine applications a well defined particle size and stability of administered colloids is of great importance. A fast and reliable sizing technique for routine quality control is therefore essential. This paper evaluates autocorrelation spectroscopy with an instrument capable of analysing several peaks simultaneously. A total of nine 99mTc-labelled colloids and one 99Y-labelled colloid were studied. The autocorrelation spectroscopy measurements were compared with the standard sizing technique of microfiltration. A good agreement between the sizing techniques was found for most of the colloids. The reproducibility of successive measurements was within ±12% and ±40% when using unimodal analysis and SDP analysis, respectively. Autocorrelation spectroscopy was found to be well suited for particle sizing and stability tests of radiolabelled colloids.
Similar content being viewed by others
References
Atkins HL, Hauser W, Richards P (1970) Factors affecting distribution of technetium-sulfur colloid. J Reticuloendothel Soc 8:176–184
Bergqvist L, Strand SE, Persson BRR (1983) Particle sizing and biokinetics of interstitial lymphoscintigraphic agents. Semin Nucl Med 13:9–19
Bergqvist L, Sundberg R, Rydén S, Strand SE (1987) The “critical colloid dose” in studies of reticuloendothelial function. J Nucl Med 28:1424–1429
Billinghurst MW, Jette D (1979) Colloidal particle-size determination by gel filtration. J Nucl Med 20:133–137
Davis MA, Jones AG, Trindade H (1974) A rapid and accurate method for sizing radiocolloids. J Nucl Med 15:923–928
Frier M (1981) Phagocytosis. In: Cox PM (ed) Progress in Radiopharmacology (vol 2). Elsevier/North Holland Biomedical Press, Amsterdam, pp 249–260
Frier M, Griffiths P, Ramsey A (1981) The physical and chemical characteristics of sulphur colloids. Eur J Nucl Med 6:255–260
Lim TK, Bloomfield VA, Krejcarek G (1979) Size and charge distributions of radiocolloid particles. Int J Appl Rad Isot 30:531–536
Lines RW (1986) Particle size measurement by auto-correlation spectroscopy. Anal Proc 23:51–54
Pedersen B, Kristensen K (1981) Evaluation of methods for sizing of colloidal radiopharmaceuticals. Eur J Nucl Med 6:521–526
Persson RBR, Naversten Y (1970) Technetium-99m sulfide colloid preparation for scintigraphy of the reticuloendothelial system. Acta Radiol Ther Phys Biol 9:567–576
Persson RBR, Strand SE, Knöös T (1978) Radioanalytical studies of 99mTc-labelled colloids and macromolecules with gel chromatography column scanning technique. J Radioanal Chem 43:275–286
steigman J, Solomon NA, Hwang LLY (1986) Technetium-sulfur colloid. Appl Radiat Isot 37:223–229
Strand SE, Andersson L, Bergqvist L (1988) Applications and characterization of radiolabeled or magnetizable nano- and microparticles for RES, lymph, and blood flow studies. In: Rembaum A, Tökés ZA (eds) Microspheres: Medical and Biological Applications. CRC Press, Boca Raton, Florida, pp 193–227
Strand SE, Bergqvist L (1989) Radiolabeled colloids and macromolecules in the lymphatic system. In: Bruck S (ed) Critical Reviews in Therapeutic Drug Carrier Systems. CRC Press, Boca Raton, Florida (in press)
Warbick A, Ege GN, Henkelman RM, Maier G, Lyster DM (1977) An evaluation of radiocolloid sizing techniques. J Nucl Med 18:827–834
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bergqvist, L., Strand, SE. Autocorrelation spectroscopy for particle sizing and stability tests of radiolabelled colloids. Eur J Nucl Med 15, 641–645 (1989). https://doi.org/10.1007/BF00251676
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00251676