Summary
The method of volume summation (V = T(A1 + A2...An ) was used to measure the size of extradural hematomas. The accuracy was tested on six different artificial silicone hematomas and the mean difference was-2.7 ml, SD 3.7 ml. The reproducibility was tested on CT scans of clinical hematomas, SD was 2.1 ml. An empirical formula for volume estimation then found: 0.5xheightxlengthxdepth was moderately reliable, while midline shift and “vesselfree space” were poor indicators of size. In conclusion, the volume summation with manual outlining was found to be highly accurate, but the problems of CT smoothing, spectral shift artifact, partial volume effect and separation of the hematoma from other structures must be considered.
Similar content being viewed by others
References
French BN, Dublin AB (1977) The value of computerized tomography in the management of 1000 consecutive head injuries. Surg Neurol 7:171–183
Espersen JO, Petersen OF (1981) Computerized tomography in patients with head injuries. Relation between CT scans and clinical findings in 96 patients. Acta Neurochir 56:201–217
Erichson K, Håkonsson S (1981) Computed tomography of epidural hematomas. Association with intracranial lesions and clinical correlation. Acta Radiol (Stockh) 22:513–519
Habash AH, Sortland O, Zwetnow NN (1982) Epidural hematoma. Pathophysiological significance of extravasation and arteriovenous shunting. Acta Neurochir 60:7–27
Mendelow AD, Karmi MZ, Poul KS, Fuller GAG, Gillingham FJ (1979) Extradural haematoma: effect of delayed treatment. Br Med J 1240–1242
Petersen OF, Espersen JO (1984) How to distinguish between bleeding and coagulated hematomas on the plain CT scanning. Neuroradiology 26 (in press)
Gyldensted C (1977) Measurements of the normal ventricular system and hemispheric sulci of 100 adults with computed tomography. Neuroradiology 14:183–192
Haug C (1977) Age and sex dependence of the size of normal ventricles on CT. Neuroradiology 14:201–204
Pentlow KS, Rottenberg DA, Deck MDF (1978) Partial volume summation: a simple approach to ventricular volume determination from CT. Neuroradiology 16:130–138
Gado M, Huges CP, Danziger N, Chi D, Jost G, Berg L (1982) Volumetric measurements of the cerebrospinal fluid spaces in demented subjects and controls. Radiology 144:535–538
Zatz LM, Jerigan TL, Alumada AJ (1982) Intracranial fluid volume. AJNR 3:1–11
Breimann RS, Beck JN, Korobkin M, Glenny R, Akwari OE, Heaston DK, Moore AV, Ram PC (1982) Volume determinations using computed tomography. AJR 138:329–333
Zatz LM, Alvarez RE (1977) An inaccuracy in computed tomography: the energy dependence of CT values. Radiology 124:91–97
Di Chiro G, Brooks RA, Dubol L, Chwe E (1978) The apical artifact: elevated attenuation values towards the apex of the skull. J Comput Assist Tomogr 2:65–70
Baxter BS, Sorenson JA (1981) Factors affecting the measurement of size and CT number in computed tomography. Invest Radiol 16:337–341
Norman D, Price D, Boyd D, Fishman R, Newton TH (1977) Quantitative aspects of computed tomography of the blood and cerebrospinal fluid. Radiology 123:335–338
New PEJ, Aronow S (1976) Attenuation measurements of whole blood and bloodfractions in computed tomography. Radiology 121:635–640
Zimmerman RA, Bilanuik LT (1982) Computed tomographic staging of traumatic epidural bleeding. Radiology 144: 809–812
Sabattini Z (1982) Evaluation and measurement of the normal ventricular and subarachnoidal spaces by CT. Neuroradiology 23:1–5
Koehler PR, Anderson RE, Baxter BS (1979) The effect of computed tomography viewer controls on anatomical measurements. Radiology 130:189–194
Cordobes F, Lobato RD, Rivas JJ, Muñoz MJ, Chillou D, Portillo JM, Lamas E (1981) Observations on 82 patients with extradural hematoma. J Neurosurg 54:179–186
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Petersen, O.F., Espersen, J.O. Extradural hematomas: Measurement of size by volume summation on CT scanning. Neuroradiology 26, 363–367 (1984). https://doi.org/10.1007/BF00327488
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00327488