Pathological findings of the aortic homograft in a patient with tetralogy of Fallot twenty years after implantation

  • Originals
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Summary

We report pathological findings of the aortic homograft in a 27-year-old patient who died 20 years after implantation at the time of correction of tetralogy of Fallot. Although calcification of the homograft was severe with degeneration of valve leaflets, no functional obstruction of the homograft was found as a conduit. This observation may suggest a beneficial aspect of the aortic homograft as the right ventricle to the pulmonary artery conduit late after corrective surgery even if calcification was not avoided.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ross DN, Somerville J (1966) Correction of pulmonary atresia with a homograft aortic valve. Lancet 2: 1446–1447

    PubMed  Google Scholar 

  2. Shabbo FP, Wain WH, Ross DN (1980) Right ventricular outflow reconstruction with aortic homograft conduit: analysis of the long-term results. Thorac Cardiovasc Surg 28: 21–25

    PubMed  Google Scholar 

  3. Di Carlo D, de Leval MR, Stark J (1984) “Fresh” antibiotic sterilized aortic homografts in extracardiac valved conduits: long-term results. Thorac Cardiovasc Surg 32: 10–14

    PubMed  Google Scholar 

  4. Fontan F, Choussat A, Deville C, Doutremepuich C, Coupillaud J, Vosa C (1984) Aortic valve homografts in the surgical treatment of complex cardiac malformations. J Thorac Cardiovasc Surg 87: 649–657

    PubMed  Google Scholar 

  5. Kay PH, Ross DN (1985) Fifteen years' experience with the aortic homograft: the conduit of choice for right ventricular outflow reconstruction. Ann Thorac Surg 40: 360–364

    PubMed  Google Scholar 

  6. Saravalli OA, Somerville J, Jefferson KE (1980) Calcification of aortic homografts used for reconstruction of the right ventricular outflow tract. J Thorac Cardiovasc Surg 80: 909–920

    PubMed  Google Scholar 

  7. McGoon DC, Danielson GK, Puga FJ, Ritter DG, Mair DD, Ilstrup DM (1982) Late results after extracardiac conduit repair for congenital cardiac defects. Am J Cardiol 49: 1741–1749

    PubMed  Google Scholar 

  8. Schaff HV, DiDonato RM, Danielson GK, Puga FJ, Ritter DG, Edwards WD, McGoon DC (1984) Re-operation for obstructed pulmonary ventricle-pulmonary artery conduits: early and late results. J Thorac Cardiovasc Surg 88: 334–343

    PubMed  Google Scholar 

  9. Kawashima Y, Naito Y, Kitamura S, Nakano S, Miyamoto T, Fujita T, Fujino M, Kozuka T, Manabe H (1974) Use of large homograft artery with semilunar valve for correction of tetralogy of Fallot. J Thorac Cardiovasc Surg 67: 685–693

    PubMed  Google Scholar 

  10. Livi U, Abdulla AK, Parker R, Olsen E, Ross DN (1987) Viability and morphology of aortic and pulmonary homografts. J Thorac Cardiovasc Surg 93: 755–760

    PubMed  Google Scholar 

  11. Downing TP, Danielson GK, Schaff HV, Puga FJ, Edwards WD, Driscoll DJ (1985) Replacement of obstructed right ventricular-pulmonary arterial valved conduits with nonvalved conduits in children. Circulation 72 (Suppl II): II-84–II-87

    Google Scholar 

  12. Cobanoglu A, Abbruzzese PA, Freimanis I, Garcia CE, Grunkemeier G, Starr A (1984) Pericardial baffle complications following the Mustard operation. Age-related incidence and ease of management. J Thorac Cardiovasc Surg 87: 371–378

    PubMed  Google Scholar 

  13. Agarwal KC, Edwards WD, Feldt RH, Danielson GK, Puga FJ, McGoon DC (1981) Clinicopathological correlates of obstructed right-sided porcine-valved extracardiac conduits. J Thorac Cardiovasc Surg 81: 591–601

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kobayashi, J., Kawashima, Y., Matsuda, H. et al. Pathological findings of the aortic homograft in a patient with tetralogy of Fallot twenty years after implantation. Heart Vessels 5, 98–101 (1990). https://doi.org/10.1007/BF02058325

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02058325

Key words

Navigation