Abstract
Statistical methods for the evaluation of quantitative visual fields are presented in addition to a mathematical description of the calculation of different visual field indices. The “mean defect” is important for diffuse damage as well as for follow-up in advanced stages. “Short-term fluctuation” provides information about the reliability of the results as well as about possible early damage. “Corrected loss variance” quantifies local defects in an early stage; it also separates real local defects from increased scatter. “Skewness” is a test for very early local defects, and “spatial correlation” provides a measurement of the clustering of any local defects that may be present.
Similar content being viewed by others
References
Augustiny L, Flammer J (1985) The influence of artificially induced visual field defects on the visual field indices. Doc Ophthalmol Proc Ser 42:55–67
Aulhorn E, Harms H (1967) Early visual field defects in glaucoma. In: Leydhecker W (Ed) Glaucoma. Tutzing Symposium 1966. Karger, Basel, pp 151–185
Bebie H (1985) Computerized techniques of visual field comparison. In: Drance SM, Anderson DR (eds) Automated perimetry in glaucoma: a practical guide. Grune and Stratton, Orlando London, pp 147–160
Bebie H, Fankhauser F, Spahr J (1976) Static perimetry: strategies. Acta Ophthalmol 54:325–338
Brechner RJ, Whalen WR (1984) Creation of the transformed Q statistic probability distribution to aid in the detection of abnormal computerized visual fields. Ophthalmic Surg 15:833–836
Fankhauser F (1976) Problems related to the design of automatic perimeters. Doc Ophthalmol 47:89–138
Flammer I (1984): The Octopus glaucoma program G1. Proceedings, Third Octopus Users' Society Meeting, Denver 1984, p 25
Flammer J (1985a) Normal values in computerized perimetry. In: Whalen WR, Spaeth GL (eds) Computerized visual fields. Slack, Thorofare, pp 161–164
Flammer J (1985b): Fluctuations in the visual field. In: Drance SM, Anderson DR (eds) Automated perimetry for glaucoma. Grune and Stratton, Orlando London, pp 161–173
Flammer J, Drance SM (1983a) The effect of a number of glaucoma medications on the differential light threshold. Doc Ophthalmol Proc Ser 35:145–148
Flammer J, Drance SM (1983b) The effect of acetazolamide on the differential light threshold. Arch Ophthalmol 101:1378–1380
Flammer J, Drance SM (1984) Correlation between colour vision scores quantitative perimetry in glaucoma suspects. Arch Ophthalmol 102:38–39
Flammer J, Drance SM, Schulzer M (1983) The estimation and testing of the components of long-term fluctuation of the differential light threshold. Doc Ophthalmol Proc Ser 35:383–389
Flammer J, Drance SM, Fankhauser F, Augustiny L (1984a) The differential light threshold in automatic static perimetry: factors influencing the short-term fluctuation. Arch Ophthalmol 102:876–879
Flammer J, Drance SM, Zulauf M (1984b) Differential light threshold: short- and long-term fluctuation in patients with glaucoma, normal controls and glaucoma suspects. Arch Ophthalmol 102:704–706
Flammer J, Drance SM, Augustiny L, Funkhouser A (1985): Quantification of glaucomatous visual field defects with automated perimetry. Invest Ophthalmol Vis Sci 26: 176–181
Jenni A, Flammer J, Funkhouser A, Fankhauser F (1983) Special Octopus software for clinical investigation. Doc Ophthalmol Proc Ser 35:351–356
Octopus-Manual (1978) Interzeag AG, Rietbachstrasse 5, CH-8952 Schlieren
Program DELTA (1981) Interzeag AG, Rietbachstrasse 5, CH-8952 Schlieren
Author information
Authors and Affiliations
Additional information
Supported by the Swiss National Fund (no. 3790-0.84)
Rights and permissions
About this article
Cite this article
Flammer, J. The concept of visual field indices. Graefe's Arch Clin Exp Ophthalmol 224, 389–392 (1986). https://doi.org/10.1007/BF02173350
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02173350