Skip to main content
Log in

Abstract

Statistical methods for the evaluation of quantitative visual fields are presented in addition to a mathematical description of the calculation of different visual field indices. The “mean defect” is important for diffuse damage as well as for follow-up in advanced stages. “Short-term fluctuation” provides information about the reliability of the results as well as about possible early damage. “Corrected loss variance” quantifies local defects in an early stage; it also separates real local defects from increased scatter. “Skewness” is a test for very early local defects, and “spatial correlation” provides a measurement of the clustering of any local defects that may be present.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Augustiny L, Flammer J (1985) The influence of artificially induced visual field defects on the visual field indices. Doc Ophthalmol Proc Ser 42:55–67

    Google Scholar 

  • Aulhorn E, Harms H (1967) Early visual field defects in glaucoma. In: Leydhecker W (Ed) Glaucoma. Tutzing Symposium 1966. Karger, Basel, pp 151–185

    Google Scholar 

  • Bebie H (1985) Computerized techniques of visual field comparison. In: Drance SM, Anderson DR (eds) Automated perimetry in glaucoma: a practical guide. Grune and Stratton, Orlando London, pp 147–160

    Google Scholar 

  • Bebie H, Fankhauser F, Spahr J (1976) Static perimetry: strategies. Acta Ophthalmol 54:325–338

    Google Scholar 

  • Brechner RJ, Whalen WR (1984) Creation of the transformed Q statistic probability distribution to aid in the detection of abnormal computerized visual fields. Ophthalmic Surg 15:833–836

    Google Scholar 

  • Fankhauser F (1976) Problems related to the design of automatic perimeters. Doc Ophthalmol 47:89–138

    Google Scholar 

  • Flammer I (1984): The Octopus glaucoma program G1. Proceedings, Third Octopus Users' Society Meeting, Denver 1984, p 25

  • Flammer J (1985a) Normal values in computerized perimetry. In: Whalen WR, Spaeth GL (eds) Computerized visual fields. Slack, Thorofare, pp 161–164

    Google Scholar 

  • Flammer J (1985b): Fluctuations in the visual field. In: Drance SM, Anderson DR (eds) Automated perimetry for glaucoma. Grune and Stratton, Orlando London, pp 161–173

    Google Scholar 

  • Flammer J, Drance SM (1983a) The effect of a number of glaucoma medications on the differential light threshold. Doc Ophthalmol Proc Ser 35:145–148

    Google Scholar 

  • Flammer J, Drance SM (1983b) The effect of acetazolamide on the differential light threshold. Arch Ophthalmol 101:1378–1380

    Google Scholar 

  • Flammer J, Drance SM (1984) Correlation between colour vision scores quantitative perimetry in glaucoma suspects. Arch Ophthalmol 102:38–39

    Google Scholar 

  • Flammer J, Drance SM, Schulzer M (1983) The estimation and testing of the components of long-term fluctuation of the differential light threshold. Doc Ophthalmol Proc Ser 35:383–389

    Google Scholar 

  • Flammer J, Drance SM, Fankhauser F, Augustiny L (1984a) The differential light threshold in automatic static perimetry: factors influencing the short-term fluctuation. Arch Ophthalmol 102:876–879

    Google Scholar 

  • Flammer J, Drance SM, Zulauf M (1984b) Differential light threshold: short- and long-term fluctuation in patients with glaucoma, normal controls and glaucoma suspects. Arch Ophthalmol 102:704–706

    Google Scholar 

  • Flammer J, Drance SM, Augustiny L, Funkhouser A (1985): Quantification of glaucomatous visual field defects with automated perimetry. Invest Ophthalmol Vis Sci 26: 176–181

    Google Scholar 

  • Jenni A, Flammer J, Funkhouser A, Fankhauser F (1983) Special Octopus software for clinical investigation. Doc Ophthalmol Proc Ser 35:351–356

    Google Scholar 

  • Octopus-Manual (1978) Interzeag AG, Rietbachstrasse 5, CH-8952 Schlieren

  • Program DELTA (1981) Interzeag AG, Rietbachstrasse 5, CH-8952 Schlieren

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by the Swiss National Fund (no. 3790-0.84)

Rights and permissions

Reprints and permissions

About this article

Cite this article

Flammer, J. The concept of visual field indices. Graefe's Arch Clin Exp Ophthalmol 224, 389–392 (1986). https://doi.org/10.1007/BF02173350

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02173350

Keywords

Navigation