Skip to main content
Log in

Nonanastomotic Aneurysm Formation in a Dacron Arterial Graft: report of a Case

  • Case Reports
  • Published:
Surgery Today Aims and scope Submit manuscript

Abstract

Dacron prostheses are the most widely used grafts in replacement procedures for abdominal aortic aneurysms, having been proven as the most reliable substitute for arterial replacement. However, we present herein the rare case of an 82-year-old woman in whom nonanastomotic aneurysm formation occurred in the graft as a complication associated with a Dacron prosthesis. The patient presented with a pulsatile mass in the right inguinal region. She had undergone surgery 13 years earlier for an abdominal aortic aneurysm, at which time an aortobifemoral graft reconstruction had been performed with a double-velour knitted Dacron prosthesis. The pulsatile mass was found to be a nonanastomotic aneurysm of the right limb of the bifurcated graft with an intact distal anastomosis. In this case, the development of the graft aneurysm seemed to result from deterioration of the Dacron prosthesis itself due to mechanical fatigue caused by the inguinal band.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Berger K, Sauvage LR (1981) Late fiber deterioration in DacronR arterial grafts. Ann Surg 193:477–491

    PubMed  Google Scholar 

  2. Trippestad A (1985) Late rupture of knitted Dacron double velour arterial prostheses. Acta Chir Scand 151:391–395

    PubMed  Google Scholar 

  3. Cooley DA, Subran A, Houchin DP (1981) Clinical experience in 1,940 patients with double velour knitted Dacron vascular prostheses: With particular reference to dilatation and aneurysm formation. Bull Texas Heart Institute 8:320–332

    Google Scholar 

  4. Ozaki S, Negishi N, Hagiwara H, Ishii Y, Okamoto I, Shinohara H, Muramatsu T, Ichiwata M, Suzuki K, Okumura H, Shimamura M, Sezai Y (1988) A case of non-anastomotic aneurysm of Dacron graft (in Japanese with English abstract). Nippon Rinshou Geka Igakkai Zasshi (J Jpn Soc Clin Surg) 49:2221–2227

    Google Scholar 

  5. Ohara I, Nakano S (1958) Rupture of arterial plastic prosthesis (Amylon-polyethylene tube). Report of a case and experimental studies. Arch Surg 77:55–60

    Google Scholar 

  6. Kumada J, Takemiya S, Matsumoto A, Wada T, Matsushita K (1976) Fates of synthetic grafts in clinical cases (in Japanese). Geka (Surgery) 38:610–615

    Google Scholar 

  7. Shirakata S, Hashimoto T, Murayama Y, Kitaura K, Esato S, Ohga K, Nakaji S, Oka T (1985) Prosthetic aneurysm in an axillofemoral Dacron bypass (in Japanese). Myakkangaku (J Jpn Coll Angiol) 17:295–300

    Google Scholar 

  8. Yasuda K, Tanabe T (1982) Complications due to deterioration of the synthetic grafts - Aneurysmal formation of Sparks graft and changes of Dacron graft (in Japanese). Junkankika (Cardioangiology) 11:89–92

    Google Scholar 

  9. Komoto Y (1982) Aneurysmal formation due to rupture of the synthetic graft (in Japanese). Junkankika (Cardioangiology) 11:92–94

    Google Scholar 

  10. Yasuda K, Tanabe T, Komoto Y, Kasai Y, Tsuburaya T, Sano F, Kusaba A, Kina M, Watanabe T, FuruyamaM, Okadome K, Muto Y, Inokuchi K, Matsumoto A, Katsumura T, Hirose M (1982) Postoperative complication due to deterioration of the synthetic arterial grafts (in Japanese). Junkankika (Cardioangiology) 11:89–106

    Google Scholar 

  11. Tominaga T, Toufukuji M, Ueyama M, Amata N, Sasaki S, Araki J, Kobatake O, Shibazaki S, Matano I, Watanabe A (1984) A case of graft aneurysm post axillo-femoral bypass (in Japanese). Nippon Rinshou Geka Igakkai Zasshi (J Jpn Soc Clin Surg) 45:239

    Google Scholar 

  12. Akimoto N, Kawachi K, Tamura K, Hakojima A, Shimizu T, Murakoshi S, Ishimaru S, Koike S, Furukawa K, Takahashi M (1986) A case of graft aneurysm of obturator bypass due to mechanical fatigue (in Japanese). Nippon Rinshou Geka Igakkai Zasshi (J Jpn Soc Clin Surg) 47:1115

    Google Scholar 

  13. Nakajima J, Ikegami T, Ishihara T, Murakami K, Morimoto K (1986) A false aneurysm caused by the rupture of double velour Dacron graft. A case report (in Japanese with English abstract). Nippon Geka Gakkai Zasshi (J Jpn Surg Soc) 87:921–925

    Google Scholar 

  14. Takenaka H, Esato K, Akimoto F, Fujioka K, Kawachi Y, Nakamura K, Nishiyama T (1988) Pseudoaneurysm due to rupture of Dacron graft (in Japanese with English abstract). Nippon Rinshou Geka Igakkai Zasshi (J Jpn Soc Clin Surg) 49:2024–2027

    Google Scholar 

  15. Moriyama M, Sakaguchi Y, Ito F, Chiba T, Okudaira Y, Ayabe K (1988) A case of graft aneurysm after F-P bypass 6 years previously (in Japanese with English abstract). Nippon Rinshou Gaka Igakkai Zasshi (J Jpn Soc Clin Surg) 49:731–734

    Google Scholar 

  16. Kamiya K, Yamaguchi H, Tsuji Y, KatsukiY, Yasuda T, Nishimura A, Muranaga S (1989) A case of nonanastomotic Dacron graft aneurysm (in Japanese). Hokkaido Geka Zasshi (Hokkaido J Surg) 34:148

    Google Scholar 

  17. Tsubaki M, Matsumoto K, Kikutsuji T, Shiba K, Kameoka Y, Matsunaga H, Ashizuka S, Ishikawa M, Ogasawara E (1990) A case of pseudoaneurysm due to rupture of the Dacron graft (in Japanese). Ehime Igaku 9 (Ehime Med J):896

    Google Scholar 

  18. Sasaki S, Yoshida H, Kamohara Y, Ito T, Nakagawa A, Sayama J, Nakajima Y, Kuritani Y, Maeyama T, Hirano T (1990) A case of nonanastomotic Dacron graft aneurysm (in Japanese). Nippon Kyobu Geka Igakkai Zasshi (J Jpn Soc Thorc Surg) 38:919

    Google Scholar 

  19. Mori A, Eguchi H, Sakata H, Aso M, Imamura S, Hamada T (1991) A case of pseudoaneurysm due to rupture of the Dacron graft (in Japanese with English abstract). Nippon Rinshou Geka Igakkai Zasshi (J Jpn Soc Clin) 52:199–202

    Google Scholar 

  20. Umezawa H, Negishi N, Niino N, Maeda H, Suzuki K, Haga N, Sezai A, Chiku N, Yamada H, Ohata M, Sezai Y (1992) A case of the Dacron graft aneurysm (abstract; in Japanese). Geka Shudankai 745:39

    Google Scholar 

  21. Okamoto J, Sasaki S, Asada K, Kodama T, Morita M, Takeuchi A (1993) Aneurysm of an Axillo-Femoral Dacron arterial graft occuring twelve years after implantation (in Japanese with English abstract). Jpn J Vase Surg 2:107–113

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Han, I., Shigematsu, H., Nunokawa, M. et al. Nonanastomotic Aneurysm Formation in a Dacron Arterial Graft: report of a Case. Surg Today 24, 1007–1010 (1994). https://doi.org/10.1007/BF02215815

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02215815

Key Words

Navigation