Abstract
Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays have been minimized by using a direct, piezoelectrically operated mass spectrometer inlet rather than an inlet capillary, by locating the mass spectrometer inlet and flow sensors in the same plane, and by incorporating design features which enhance the mass spectrometer response. Convenience in system operation and data analysis has been enhanced by integrating a computer into the system design so that the computer performs on-line data analysis and control functions and provides the primary interface between the experimenter and the instruments. Miniaturization of the instruments permits close coupling to an exercising subject.
Similar content being viewed by others
References
Beaver, W.L., K. Wassermann, and B.J. Whipp. On-line computer analysis and breath-by-breath graphical display of exercise function tests.J. Appl. Physiol. 34:128–132, 1973.
Casaburi, R., B.J. Whipp, K. Wassermann, W.L. Beaver, and S.N. Kogal. Ventilatory and gas exchange dynamics in response to sinusoidal work.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 42:300–311, 1977.
Fowler, K.T. The respiratory mass spectrometer.Phys. Med. Biol. 14:185–199, 1969.
Green, I.D. and M.S. Nesarajah. Water vapor pressure of end-tidal air of normals and chronic bronchitis.J. Appl. Physiol. 24:229–231, 1966.
Johnson, T.S., G.D. Swanson, I.E. Sodal, J.T. Reeves, and R.W. Virtue. A closed lung system study of inert gas absorption.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 47:240–244, 1979.
Linnarsson, D. Dynamics of pulmonary gas exchange and heart rate changes at start and end of exercise.Acta Physiol. Scand. Suppl. 415:1–68, 1974.
Linnarsson, D. and B. Lindborg. Breath-by-breath measurement of respiratory gas exchange using on-line analog computation.Scand. J. Clin. Lab. Invest. 34:219–224, 1974.
Martin, J.P. Design and development of an Unified System for Detection of Life on Mars. NASA Report MCR-74-421.
Micco, A.J. A sensitive flow direction sensor.J. Appl. Physiol. 35:420–422, 1973.
Pearce, D.H. and H.T. Milhorn, Jr. Dynamic and steady state response to bicycle exercise.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 42:959–967, 1977.
Pearce, D.H., H.T. Milhorn, Jr., G.H. Holoman, Jr., and W.J. Reynolds. Computer-based system for analysis of respiratory responses to exercise.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 42:968–975, 1977.
Peterson, B.T., M.F. Petrini, R.W. Hyde, and B.F. Schreiner. Pulmonary tissue volume in dogs during pulmonary edema.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 44:782–795, 1978.
Sackner, M.A., D. Geeneltch, M.S. Heiman, S. Epstein, and N. Atkins. Diffusion capacity, membrane diffusion capacity, capillary blood volume, pulmonary tissue volume, and cardiac output measured by a rebreathing technique.Am. Rev. Respir. Diseases 111:157–165, 1975.
Scheid, P., H. Slama, and J. Piiker. Electronic compensation of the effects of water vapor in respiratory mass spectrometry.J. Appl. Physiol. 30:258–260, 1971.
Septier, A. Production of ion beams of high intensity. InFocusing of Charged Particles, edited by A. Septier. New York, London: Academic Press, 1967.
Sherrill, D.L., R.H. Jones, and R.M. Engeman. Analysis of dynamic ventilatory response to impulse work loads.Biomed. Sci. Instrum. 18:11–18, 1982.
Smidt, U. and G.V. Nieding. Today’s respiratory mass spectrometer.Pneumonologie 151:241–295, 1975.
Sodal, I.E., L. Hoivik, A.J. Micco, J.V. Weil, and N.W. Baer. Method and inlet control systems for controlling gas flow sample to an evacuated chamber. U.S. Patent No. 3,926,209. 1975.
Sodal, I.E., A.J. Micco, and J.V. Weil. An improved fast response oxygen analyzer with high accuracy for respiratory gas analysis.Biomed. Sci. Instrum. 11:21–24, 1975.
Sodal, I.E. and G.D. Swanson. Mass spectrometry: Current technology and implications for anesthesia. InLow Flow and Closed System Anesthesia, edited by J.A. Aldrete, H.J. Lowe, and R.W. Virtue. New York: Grune & Stratton, 1979, p.p. 167–182.
Swanson, G.D. Breath-to-breath considerations for gas exchange kinetics. InExercise, Bioenergetics and Gas Exchange, edited by P. Cerretelli and B.J. Whipp. Amsterdam: Elsevier/North Holland, 1980, pp. 211–222.
Swanson, G.D., I.E. Sodal, and J.T. Reeves. Sensitivity of breath-to-breath gas exchange measurements to expiratory flow errors.IEEE Trans. Biomed. Eng. 28:749–754, 1981.
Triebwasser, J.H., R.L. Johnson, Jr., R.P. Burpo, J.C. Cambell, W.C. Reardon, and C.G. Blomqvist. Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements.Aviat. Space Environ. Med. 48:203–209, 1977.
Weil, J.V., I.E. Sodal and R.D. Speck. A modified fuel cell for the analysis of oxygen concentration of gases.J. Appl. Physiol. 23:419, 1967.
Weisiger, K., G.D. Swanson, and J.T. Reeves. Measurement of lung tissue volume and cardiac output by uptake of multiple inspired soluble gases. Abstract.Fed. Proc. Fed. Am. Soc. Exp. Biol. 36:536, 1977.
Wessel, H.U., R.L. Stout, C.K. Basdtanier, and H.M. Paul. Breath-by-breath variation of FRC: Effect on VO2 and VCO2 measured at the mouth.J. Appl. Physiol: Respir. Environ. Exercise Physiol. 46(6):1122–1126, 1979.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sodal, I.E., Swanson, G.D., Micco, A.J. et al. A computerized mass spectrometer and flowmeter system for respiratory gas measurements. Ann Biomed Eng 11, 83–99 (1983). https://doi.org/10.1007/BF02367493
Issue Date:
DOI: https://doi.org/10.1007/BF02367493