Skip to main content
Log in

Theory of the oscillometric maximum and the systolic and diastolic detection ratios

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

It is proposed that the maximum in cuff pressure oscillations during oscillometry is due to the buckling of the brachial artery under a cuff. This theory is investigated by means of a mathematical model of oscillometry that includes the mechanics of the occlusive arm cuff, the arterial pressure pulse waveform, and the mechanics of the brachial artery. A numerical solution is provided for the oscillations in cuff pressure for one cycle of cuff inflation and deflation. The buckling pressure is determined from actual arterial data and the von Mises buckling criteria. The buckling of an artery under a cuff occurs near — 2 to 0 mm Hg transmural pressure. This effect corresponds with a maximum arterial compliance and maximum cuff pressure oscillations when cuff pressure is nearly equal to mean arterial pressure (MAP), in support of the suggested theory. The model was also found to demonstrate the basic characteristics of experimental oscillometry, such as an increasing and decreasing amplitude in oscillations as cuff pressure decreases, the oscillations that occur when cuff pressure is above systolic pressure, maximum oscillation amplitudes in the range of 1 to 4 mm Hg, and an oscillatory maximum at cuff pressure equal to MAP. These findings support the case that the model is representative of oscillometry. Finally, the model predicted values for the systolic and diastolic detection ratios of 0.593 and 0.717, respectively, similar to those found empirically. These ratios alter with blood pressure, but the tightness of the cuff wrap did not change their value.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Alexander, H.; Cohen, M.; Steinfeld, L. Criteria in the choice of an occluding cuff for the indirect measurement of blood pressure. Med. Biol. Eng. Comput. 15:2–10; 1977.

    CAS  PubMed  Google Scholar 

  2. Brower, R.W.; Noordergraaf, A. Theory of steady flow in collapsible tubes and veins. In: Baan, J.; Noordergraaf, A.; Raines, J. eds. Cardiovascular system dynamics. Cambridge, MA: Cambridge, 1978: pp. 256–265.

  3. Drzewiecki, G.M.; Rabbany, S.Y.; Melbin, J.; Noordergraaf, A. Generalization of the transmural pressure-area relation for the femoral artery. Proc. 7th Ann. Conf. EMBS/IEEE, Chicago, IL; 1985: pp. 507–510.

  4. Drzewiecki, G.M.; Moubarak, I.F. Transmural pressurearea relation for veins and arteries. Proc. 14th Ann. Northeast Bioeng. Conf., Univ. New Hampshire; 1988: pp. 269–272.

  5. Drzewiecki, G.M.; Melbin, J.; Noordergraaf, A. The Korotkoff sound. Ann. Biomedical Eng. 17:325–359; 1989.

    CAS  Google Scholar 

  6. Drzewiecki, G.M.; Karam, E.; Bansal, V.; Hood, R.; Apple, H. Mechanics of the occlusive arm cuff and its application as a volume sensor. IEEE Trans. Biomed. Eng. 40:704–708; 1993.

    Article  CAS  PubMed  Google Scholar 

  7. Flaherty, J.E.; Keller, J.B.; Rubinow, S.I. Post buckling behavior of elastic tubes and rings with opposite sides in contact. SIAM J. Applied Math. 23:446–455; 1972.

    Google Scholar 

  8. Forster, F.K.; Turney, D. Oscillometric determination of diastolic, mean, and systolic blood pressure—a numerical model. J. Biomech. Eng. 108:359–364; 1986.

    CAS  PubMed  Google Scholar 

  9. Fung, Y.C. Biodynamics—circulation. New York: Springer-Verlag; 1984.

    Google Scholar 

  10. Geddes, L.A.; M.L.; Voelz, M.; Combs, C.; Reiner, D. Characterization of the oscillometric method for measuring indirect blood pressure. Ann. Biomed. Eng. 10:271–280; 1983.

    Google Scholar 

  11. Kresch, E. Compliance of flexible tubes. J. Biomech. 12: 825–839; 1979.

    Article  CAS  PubMed  Google Scholar 

  12. Link, W.T. Techniques for obtaining information associated with an individual's blood pressure including specifically a stat mode technique. U.S. Patent #4,664, 126; 1987.

    Google Scholar 

  13. Marey, E.J. La Methode Graphique dans les Sciences Experimentales et principalement en Physiologie et en Medicine. Paris: Masson; 1885.

    Google Scholar 

  14. Mauck, G.W.; Smith, C.R.; Geddes, L.A.; Bourland, J.D. The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure: II. J. Biomech. Eng. 102:28; 1980.

    CAS  PubMed  Google Scholar 

  15. Moreno, A.H.; Katz, A.I.; Gold, L.D.; Reddy, R.V. Mechanics of the distension of dog veins and other very thinwalled tubular structures. Circ. Res. 27:1069–1079; 1970.

    CAS  PubMed  Google Scholar 

  16. Noordergraaf, A. Circulatory system dynamics. New York: Academic Press; 1978.

    Google Scholar 

  17. Pedley, T.J. Flow in collapsible tubes. In: The fluid mechanics of large blood vessels. Oxford: Cambridge University Press; Chap. 6, pp. 301–368, 1980.

    Google Scholar 

  18. Ramsey III, M. Noninvasive blood pressure determination of mean arterial pressure. Med. Biol. Eng. Comp. 17:11–18; 1979.

    Google Scholar 

  19. Shapiro, A.H. Steady flow in collapsible tubes. Trans. ASME (ser. K.) J. Biomech. Eng. 99:126–147; 1977.

    Google Scholar 

  20. von Mises, R. Der kritische aussendruck zylindrischer Rohre. Ver. Deut. Ing. Z. 58:750–755; 1914.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Drzewiecki, G., Hood, R. & Apple, H. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann Biomed Eng 22, 88–96 (1994). https://doi.org/10.1007/BF02368225

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02368225

Keywords

Navigation