Abstract
It is proposed that the maximum in cuff pressure oscillations during oscillometry is due to the buckling of the brachial artery under a cuff. This theory is investigated by means of a mathematical model of oscillometry that includes the mechanics of the occlusive arm cuff, the arterial pressure pulse waveform, and the mechanics of the brachial artery. A numerical solution is provided for the oscillations in cuff pressure for one cycle of cuff inflation and deflation. The buckling pressure is determined from actual arterial data and the von Mises buckling criteria. The buckling of an artery under a cuff occurs near — 2 to 0 mm Hg transmural pressure. This effect corresponds with a maximum arterial compliance and maximum cuff pressure oscillations when cuff pressure is nearly equal to mean arterial pressure (MAP), in support of the suggested theory. The model was also found to demonstrate the basic characteristics of experimental oscillometry, such as an increasing and decreasing amplitude in oscillations as cuff pressure decreases, the oscillations that occur when cuff pressure is above systolic pressure, maximum oscillation amplitudes in the range of 1 to 4 mm Hg, and an oscillatory maximum at cuff pressure equal to MAP. These findings support the case that the model is representative of oscillometry. Finally, the model predicted values for the systolic and diastolic detection ratios of 0.593 and 0.717, respectively, similar to those found empirically. These ratios alter with blood pressure, but the tightness of the cuff wrap did not change their value.
Similar content being viewed by others
References
Alexander, H.; Cohen, M.; Steinfeld, L. Criteria in the choice of an occluding cuff for the indirect measurement of blood pressure. Med. Biol. Eng. Comput. 15:2–10; 1977.
Brower, R.W.; Noordergraaf, A. Theory of steady flow in collapsible tubes and veins. In: Baan, J.; Noordergraaf, A.; Raines, J. eds. Cardiovascular system dynamics. Cambridge, MA: Cambridge, 1978: pp. 256–265.
Drzewiecki, G.M.; Rabbany, S.Y.; Melbin, J.; Noordergraaf, A. Generalization of the transmural pressure-area relation for the femoral artery. Proc. 7th Ann. Conf. EMBS/IEEE, Chicago, IL; 1985: pp. 507–510.
Drzewiecki, G.M.; Moubarak, I.F. Transmural pressurearea relation for veins and arteries. Proc. 14th Ann. Northeast Bioeng. Conf., Univ. New Hampshire; 1988: pp. 269–272.
Drzewiecki, G.M.; Melbin, J.; Noordergraaf, A. The Korotkoff sound. Ann. Biomedical Eng. 17:325–359; 1989.
Drzewiecki, G.M.; Karam, E.; Bansal, V.; Hood, R.; Apple, H. Mechanics of the occlusive arm cuff and its application as a volume sensor. IEEE Trans. Biomed. Eng. 40:704–708; 1993.
Flaherty, J.E.; Keller, J.B.; Rubinow, S.I. Post buckling behavior of elastic tubes and rings with opposite sides in contact. SIAM J. Applied Math. 23:446–455; 1972.
Forster, F.K.; Turney, D. Oscillometric determination of diastolic, mean, and systolic blood pressure—a numerical model. J. Biomech. Eng. 108:359–364; 1986.
Fung, Y.C. Biodynamics—circulation. New York: Springer-Verlag; 1984.
Geddes, L.A.; M.L.; Voelz, M.; Combs, C.; Reiner, D. Characterization of the oscillometric method for measuring indirect blood pressure. Ann. Biomed. Eng. 10:271–280; 1983.
Kresch, E. Compliance of flexible tubes. J. Biomech. 12: 825–839; 1979.
Link, W.T. Techniques for obtaining information associated with an individual's blood pressure including specifically a stat mode technique. U.S. Patent #4,664, 126; 1987.
Marey, E.J. La Methode Graphique dans les Sciences Experimentales et principalement en Physiologie et en Medicine. Paris: Masson; 1885.
Mauck, G.W.; Smith, C.R.; Geddes, L.A.; Bourland, J.D. The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure: II. J. Biomech. Eng. 102:28; 1980.
Moreno, A.H.; Katz, A.I.; Gold, L.D.; Reddy, R.V. Mechanics of the distension of dog veins and other very thinwalled tubular structures. Circ. Res. 27:1069–1079; 1970.
Noordergraaf, A. Circulatory system dynamics. New York: Academic Press; 1978.
Pedley, T.J. Flow in collapsible tubes. In: The fluid mechanics of large blood vessels. Oxford: Cambridge University Press; Chap. 6, pp. 301–368, 1980.
Ramsey III, M. Noninvasive blood pressure determination of mean arterial pressure. Med. Biol. Eng. Comp. 17:11–18; 1979.
Shapiro, A.H. Steady flow in collapsible tubes. Trans. ASME (ser. K.) J. Biomech. Eng. 99:126–147; 1977.
von Mises, R. Der kritische aussendruck zylindrischer Rohre. Ver. Deut. Ing. Z. 58:750–755; 1914.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Drzewiecki, G., Hood, R. & Apple, H. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann Biomed Eng 22, 88–96 (1994). https://doi.org/10.1007/BF02368225
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02368225