Abstract
This experimental study evaluated the feasibility of excluding artificially created aortic aneurysms in dogs with transfemorally inserted nitinol stents, serving as intraluminal bypass. Infrarenal aortic aneurysms were created in eleven dogs (28–35 kg) by end-to-end anastomosis of sacciform conduits. Single and double wire-knitted, macroporous, superelastic, self-expanding nitinol stents without any additional wrapping or in-between fabrics served as endovascular grafts. The pore size of the double-knitted stents was less than 0.7 mm2. Angiography following stent placement showed immediate exclusion of the aneurysms for the double-knitted stents. For the single-knitted stents (2 cases), partial exclusion was achieved only after considerable delay. CT studies in the dogs with the double-knitted stents revealed patency of the grafts after 3 to 5 weeks with the aneurysms totally thrombosed. So far gross pathology of 1 dog at 24 h and 1 at 12 months revealed patency of the stents. At 12 months histopathology showed a neointima covering the inner stent surface with the aneurysm filled by an organized thrombus. It is concluded, that an “open” stent with a tight meshwork appears to be a suitable device to instantly exclude artificial aneurysms of the canine aorta.
Similar content being viewed by others
References
Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann. Vasc. Surg. 5:491–499
Dotter CT, Buschmann RW, McKinney MK, Rösch J (1983) Transluminal expandable nitinol coil grafting: Preliminary report. Radiology 147:259–260
Cragg AH, Lund G, Rysavy JA, Salomonowitz E, Castaneda-Zuniga WR, Amplatz K (1984) Percutaneous arterial grafting. Radiology 150:45–49
Maass D (1986) Netre Methoden in der Gefäßchirurgie. Neue Zürcher Zeitung 35: (12.2.86):71
Balko A, Piasecki GJ, Shah DM, Carney WL, Hopkins RW, Jackson BT (1986) Transfemoral placement of intraluminal polyurethane prosthesis for abdominal aortic aneurysm. J. Surg. Res. 40:305–309
Lawrence DP, Charnsangavej C, Wright KC, Gianturco C, Wallace S (1987) Percutaneous endovascular graft: Experimental evaluation. Radiology 163:357–360
Mirich D, Wright KC, Wallace S, Yoshioka T, Lawrence DD Jr, Charnsangavej C, Gianturco C (1989) Percutaneously placed endovascular grafts for aortic aneurysms: Feasibility study. Radiology 170:1033–1037
Laborde JC, Parodi JC, Clem MF, Tio FO, Barone HD, Rivera FJ, Encarnacion CE, Palmaz JC (1992) Intraluminal bypass of abdominal aortic aneurysm: Feasibility study. Radiology 184:185–190
Budd JS, Finch DRA, Carter PG (1989) A study of the mortality from ruptured abdominal aortic aneurysms in a district community. Eur. J. Vasc Surg. 3:351–354
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hagen, B., Harnoss, BM., Trabhardt, S. et al. Self-expandable macroporous nitinol stents for transfemoral exclusion of aortic aneurysms in dogs: Preliminary results. Cardiovasc Intervent Radiol 16, 339–342 (1993). https://doi.org/10.1007/BF02603137
Issue Date: