Comparison of scatter doses from a multislice and a single slice CT scanner

  • Scientific Note
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer’s data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer’s data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer’s data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Philips Medical Systems,Brilliance CT 40/64 Channel Configuration Site Planning Guide (Revision C), Philips, 2005.

  2. GE Medical Systems,HiSpeedAdvantage CT/I — Preinstallation (Revision E Draft), General Electric Company, 1996.

  3. Lewis, M.,Radiation dose issues in multi-slice CT scanning, ImPACT London UK, 2005.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. W. Burrage.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Burrage, J.W., Causer, D.A. Comparison of scatter doses from a multislice and a single slice CT scanner. Australas. Phys. Eng. Sci. Med. 29, 257–259 (2006). https://doi.org/10.1007/BF03178574

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178574

Key words

Navigation