Skip to main content
Erschienen in: Operative Orthopädie und Traumatologie 1/2021

27.11.2020 | Surgical Techniques

Role of a spanning plate as an internal fixator in complex distal radius fractures

verfasst von: PD Dr. med. Frank J. P. Beeres, M.D. PhD, Dr. med. Rémy Liechti, M.D, PD Dr. med. Björn-Christian Link, M.D., Prof. Dr. med. Reto Babst, M.D.

Erschienen in: Operative Orthopädie und Traumatologie | Ausgabe 1/2021

Einloggen, um Zugang zu erhalten

Abstract

Objective

Minimally invasive temporary internal wrist arthrodesis as an alternative treatment method in complex distal radius fractures.

Indications

Complex distal radius fractures with dorsal and/or palmar comminution and little to no reconstruction possibilities, radiocarpal ligamentous injury, need for early weight bearing through the affected wrist (walking aids).

Contraindications

Complex hand injuries limiting the possibility to safely secure the plate at either the metacarpal or the radial shaft.

Surgical technique

Percutaneous or open reduction and fixation of the distal radius fracture. Determine the location for the two stab incisions under fluoroscopy; one over the distal radial diaphysis and one over the second or third metacarpal. A third incision over Lister’s tubercle allows transposition of the extensor pollicis longus (EPL) tendon, excision of the posterior interosseous nerve and dorsal arthrotomy. Retrograde insertion of the spanning plate. Placement of a first nonlocking screw through the glide hole into the metacarpal shaft. Under traction, a proximal screw hole is filled with a nonlocking screw into the radial diaphysis. Tightening of the cortical screws under lateral fluoroscopic view. The remaining screw holes at both the distal and proximal ends of the plate are filled with locking screws. Layered wound closure.

Postoperative management

A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation.

Results

In total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January 2019. Average age was 53.3 ± 24.5 years (range 22–95 years). Both 3.5 mm and 2.4/2.7 mm plates were used. All twelve fractures were healed after 3 months. The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 36.4 (range 8.3–70.0). There was one EPL tendon rupture, one case with extensor tendon adhesions, one periosteosynthetic fracture of the radial shaft and one complex regional pain syndrome. There was no implant failure and no infection.
Literatur
2.
Zurück zum Zitat Hammer O‑L, Clementsen S, Hast J, Šaltytė Benth J, Madsen JE, Randsborg P‑H (2019) Volar locking plates versus augmented external fixation of intra-articular distal radial fractures: functional results from a randomized controlled trial. J Bone Joint Surg Am 101:311–321. https://doi.org/10.2106/JBJS.18.00014CrossRefPubMed Hammer O‑L, Clementsen S, Hast J, Šaltytė Benth J, Madsen JE, Randsborg P‑H (2019) Volar locking plates versus augmented external fixation of intra-articular distal radial fractures: functional results from a randomized controlled trial. J Bone Joint Surg Am 101:311–321. https://​doi.​org/​10.​2106/​JBJS.​18.​00014CrossRefPubMed
6.
Zurück zum Zitat Burke EF, Singer RM (1998) Treatment of comminuted distal radius with the use of an internal distraction plate. Tech Hand Up Extrem Surg 2:248–252CrossRef Burke EF, Singer RM (1998) Treatment of comminuted distal radius with the use of an internal distraction plate. Tech Hand Up Extrem Surg 2:248–252CrossRef
7.
Zurück zum Zitat Ruch DS, Ginn TA, Yang CC, Smith BP, Rushing J, Hanel DP (2005) Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution. J Bone Joint Surg 87:945–954CrossRef Ruch DS, Ginn TA, Yang CC, Smith BP, Rushing J, Hanel DP (2005) Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution. J Bone Joint Surg 87:945–954CrossRef
12.
Zurück zum Zitat Dodds SD, Save AV, Yacob A (2013) Dorsal spanning plate fixation for distal radius fractures. Tech Hand Up Extrem Surg 17:1–7CrossRef Dodds SD, Save AV, Yacob A (2013) Dorsal spanning plate fixation for distal radius fractures. Tech Hand Up Extrem Surg 17:1–7CrossRef
15.
Zurück zum Zitat Becton JL, Colborn GL, Goodrich JA (1998) Use of an internal fixator device to treat comminuted fractures of the distal radius: report of a technique. Am J Orthop 27:619–623PubMed Becton JL, Colborn GL, Goodrich JA (1998) Use of an internal fixator device to treat comminuted fractures of the distal radius: report of a technique. Am J Orthop 27:619–623PubMed
Metadaten
Titel
Role of a spanning plate as an internal fixator in complex distal radius fractures
verfasst von
PD Dr. med. Frank J. P. Beeres, M.D. PhD
Dr. med. Rémy Liechti, M.D
PD Dr. med. Björn-Christian Link, M.D.
Prof. Dr. med. Reto Babst, M.D.
Publikationsdatum
27.11.2020
Verlag
Springer Medizin
Erschienen in
Operative Orthopädie und Traumatologie / Ausgabe 1/2021
Print ISSN: 0934-6694
Elektronische ISSN: 1439-0981
DOI
https://doi.org/10.1007/s00064-020-00686-4

Weitere Artikel der Ausgabe 1/2021

Operative Orthopädie und Traumatologie 1/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.