Abstract.

Objective: To compare two methods of assessing a change in stroke volume in response to fluid challenge: esophageal Doppler and thermodilution with the pulmonary artery catheter.
Design: Prospective study.
Setting: Department of Intensive Care of a university medical center.
Patients: 19 adult patients, intubated and sedated, with a pulmonary catheter and a clinical indication for a fluid challenge.
Interventions: Two examiners independently assessed the effect of a fluid challenge on stroke volume and cardiac output with esophageal Doppler. Thermodilution performed by an independent clinician was used as the reference. Between-method variation and interobserver variability of the Doppler method were assessed.
Measurements and results: There were no differences in stroke volume and cardiac output before volume challenge when measured with either of the two methods or by the two examiners using the esophageal Doppler. Despite a small bias between the methods and the two examiners using the esophageal Doppler (overall bias for cardiac output 0.3 l/min), the precision was poor (1.8 l/min).
Conclusions: The esophageal Doppler method is a non-invasive alternative to the pulmonary artery catheter for the assessment of stroke volume in critically ill patients. Measurement of stroke volume response to fluid challenge using esophageal Doppler shows substantial interobserver variability. Despite the poor precision between methods and investigators, similar directional changes in stroke volume can be measured.
Literatur
1.
Zurück zum Zitat Vincent JL, Dhainaut JF, Perret C, Suter P (1998) Is the pulmonary artery catheter misused? A European view. Crit Care Med 26:1283–1287PubMed Vincent JL, Dhainaut JF, Perret C, Suter P (1998) Is the pulmonary artery catheter misused? A European view. Crit Care Med 26:1283–1287PubMed
2.
Zurück zum Zitat Rackow EC (1997) Pulmonary Artery Catheter Consensus Conference. Crit Care Med 25:901PubMed Rackow EC (1997) Pulmonary Artery Catheter Consensus Conference. Crit Care Med 25:901PubMed
3.
Zurück zum Zitat Connors AF, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. J Am Med Assoc 276:889–897CrossRef Connors AF, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. J Am Med Assoc 276:889–897CrossRef
4.
Zurück zum Zitat Connors AF (1997) Right heart catheterization: Is it effective? New Horiz 5:195–200PubMed Connors AF (1997) Right heart catheterization: Is it effective? New Horiz 5:195–200PubMed
5.
Zurück zum Zitat Singer M, Bennett ED (1991) Noninvasive optimization of left ventricular filling using esophageal Doppler. Crit Care Med 9:1132–1137 Singer M, Bennett ED (1991) Noninvasive optimization of left ventricular filling using esophageal Doppler. Crit Care Med 9:1132–1137
6.
Zurück zum Zitat Singer M, Clarke J, Bennett ED (1989) Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med 17:447–452 Singer M, Clarke J, Bennett ED (1989) Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med 17:447–452
7.
Zurück zum Zitat Singer M, Allen MJ, Webb AR, Bennett ED (1991) Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 19:1138–1144 Singer M, Allen MJ, Webb AR, Bennett ED (1991) Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 19:1138–1144
8.
Zurück zum Zitat Haxby EJ, Gray MR, Rodriguez C, Nott D, Springall M, Mythen M (1997) Assessment of cardiovascular changes during laparoscopic hernia repair using oesophageal Doppler. Br J Anaesth 78:515–519PubMed Haxby EJ, Gray MR, Rodriguez C, Nott D, Springall M, Mythen M (1997) Assessment of cardiovascular changes during laparoscopic hernia repair using oesophageal Doppler. Br J Anaesth 78:515–519PubMed
9.
Zurück zum Zitat Rodriguez RM, Berumen KA (2000) Cardiac output measurement with an esophageal Doppler monitor in critically ill emergency department patients. J Emerg Med 18:159–164CrossRefPubMed Rodriguez RM, Berumen KA (2000) Cardiac output measurement with an esophageal Doppler monitor in critically ill emergency department patients. J Emerg Med 18:159–164CrossRefPubMed
10.
Zurück zum Zitat Bernardin G, Tiger F, Fouche R, Mattei M (1998) Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler system. J Crit Care 13:177–183PubMed Bernardin G, Tiger F, Fouche R, Mattei M (1998) Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler system. J Crit Care 13:177–183PubMed
11.
Zurück zum Zitat Djaiani G, Hardy I (1997) Perioperative use of the oesophageal Doppler probe (ODM II) on a patient scheduled for transmyocardial revascularization. Br J Anesth 78:760–761 Djaiani G, Hardy I (1997) Perioperative use of the oesophageal Doppler probe (ODM II) on a patient scheduled for transmyocardial revascularization. Br J Anesth 78:760–761
12.
Zurück zum Zitat Addy E, Higgins D, Singer M (1993) Use of the oesophageal Doppler to facilitate resuscitation. Emergency Med 5:37–39 Addy E, Higgins D, Singer M (1993) Use of the oesophageal Doppler to facilitate resuscitation. Emergency Med 5:37–39
13.
Zurück zum Zitat Gan TJ (2000) The esophageal Doppler as an alternative to the pulmonary artery catheter. Curr Opinion Crit Care 6:214–221CrossRef Gan TJ (2000) The esophageal Doppler as an alternative to the pulmonary artery catheter. Curr Opinion Crit Care 6:214–221CrossRef
14.
Zurück zum Zitat Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, Coussaye JE de la , Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352CrossRefPubMed Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, Coussaye JE de la , Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352CrossRefPubMed
15.
Zurück zum Zitat Jansen JR, Schreuder JJ, Settels JJ, Kloek JJ, Versprille A (1990) An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med 16:422–425PubMed Jansen JR, Schreuder JJ, Settels JJ, Kloek JJ, Versprille A (1990) An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med 16:422–425PubMed
16.
Zurück zum Zitat Le Gall JR, Lemeshow S, Saulnier F (1993) A new simplified acute physiology score (SAPS II) based on a European/North American multicenter study. J Am Med Assoc 270:2957–2963CrossRef Le Gall JR, Lemeshow S, Saulnier F (1993) A new simplified acute physiology score (SAPS II) based on a European/North American multicenter study. J Am Med Assoc 270:2957–2963CrossRef
17.
Zurück zum Zitat Medin DL, Brown DT, Wesley R, Cunnion RE, Ognibene FP (1998) Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors. J Crit Care 13:184–189PubMed Medin DL, Brown DT, Wesley R, Cunnion RE, Ognibene FP (1998) Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors. J Crit Care 13:184–189PubMed
18.
Zurück zum Zitat Boyd O, Grounds RM, Bennett ED (1993) A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. J Am Med Assoc 270:2699–2707CrossRef Boyd O, Grounds RM, Bennett ED (1993) A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. J Am Med Assoc 270:2699–2707CrossRef
19.
Zurück zum Zitat Shoemaker WC, Appel PL, Kram HB, Waxman K, Lee TS (1988) Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest 94:1176–1186PubMed Shoemaker WC, Appel PL, Kram HB, Waxman K, Lee TS (1988) Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest 94:1176–1186PubMed
20.
Zurück zum Zitat Wilson J, Woods I, Fawcett J, Whall R, Dibb W, Morris C, McManus E (1999) Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery. Br Med J 318:1099–1103 Wilson J, Woods I, Fawcett J, Whall R, Dibb W, Morris C, McManus E (1999) Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery. Br Med J 318:1099–1103
21.
Zurück zum Zitat Suffredini AF (1998) Myocardial dysfunction in sepsis: clinical and experimental investigations. Schweiz Med Wochensch 128:1444–1452 Suffredini AF (1998) Myocardial dysfunction in sepsis: clinical and experimental investigations. Schweiz Med Wochensch 128:1444–1452
22.
23.
Zurück zum Zitat Fransen EJ, Maessen JG, Hermens WT, Glatz JF, Buurman WA (2000) Peri-operative myocardial tissue injury and the release of inflammatory mediators in coronary artery bypass graft patients. Cardiovasc Res 45:853–859CrossRefPubMed Fransen EJ, Maessen JG, Hermens WT, Glatz JF, Buurman WA (2000) Peri-operative myocardial tissue injury and the release of inflammatory mediators in coronary artery bypass graft patients. Cardiovasc Res 45:853–859CrossRefPubMed
24.
Zurück zum Zitat Ivanov R, Allen J, Calvin JE (2000) The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters: a meta-analysis. Crit Care Med 28:615–619PubMed Ivanov R, Allen J, Calvin JE (2000) The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters: a meta-analysis. Crit Care Med 28:615–619PubMed
25.
Zurück zum Zitat Murdoch SD, Cohen AT, Bellamy MC (2000) Pulmonary artery catheterization and mortality in critically ill patients. Br J Anaesth 85:611–615CrossRefPubMed Murdoch SD, Cohen AT, Bellamy MC (2000) Pulmonary artery catheterization and mortality in critically ill patients. Br J Anaesth 85:611–615CrossRefPubMed
26.
Zurück zum Zitat Dalen JE, Bone RC (1996) Is it time to pull the pulmonary artery catheter? J Am Med Assoc 276:916–918CrossRef Dalen JE, Bone RC (1996) Is it time to pull the pulmonary artery catheter? J Am Med Assoc 276:916–918CrossRef
27.
Zurück zum Zitat Elliott CG, Zimmermann GA, Clemmer TP (1979) Complications of pulmonary artery catheterization in the care of critically ill patients. Chest 76:647–652PubMed Elliott CG, Zimmermann GA, Clemmer TP (1979) Complications of pulmonary artery catheterization in the care of critically ill patients. Chest 76:647–652PubMed
28.
Zurück zum Zitat Singer M, Bennett D (1989) Pitfalls of pulmonary artery catheterization highlighted by Doppler ultrasound. Crit Care Med 17:1060–1061PubMed Singer M, Bennett D (1989) Pitfalls of pulmonary artery catheterization highlighted by Doppler ultrasound. Crit Care Med 17:1060–1061PubMed
29.
Zurück zum Zitat Raper R, Sibbald WJ (1986) Misled by the wedge? Chest 89:427–434PubMed Raper R, Sibbald WJ (1986) Misled by the wedge? Chest 89:427–434PubMed
30.
Zurück zum Zitat Morris AH, Chapman RH, Gardner RM (1985) Frequency of wedge pressure errors in the ICU. Crit Care Med 13:705–708PubMed Morris AH, Chapman RH, Gardner RM (1985) Frequency of wedge pressure errors in the ICU. Crit Care Med 13:705–708PubMed
31.
Zurück zum Zitat Poeze M, Ramsay G, Greve JW, Singer M (1999) Prediction of postoperative cardiac surgical morbidity and organ failure within 4 h of intensive care unit admission using esophageal Doppler ultrasonography. Crit Care Med 27:1288–1294 Poeze M, Ramsay G, Greve JW, Singer M (1999) Prediction of postoperative cardiac surgical morbidity and organ failure within 4 h of intensive care unit admission using esophageal Doppler ultrasonography. Crit Care Med 27:1288–1294
32.
Zurück zum Zitat Lefrant JY, Muller L, Bruelle P, Pandolfi JL, L'Hermite J, Peray P, Saissi G, Coussaye JE de la, Eledjam JJ (2000) Insertion time of the pulmonary artery catheter in critically ill patients. Crit Care Med 28:355–359PubMed Lefrant JY, Muller L, Bruelle P, Pandolfi JL, L'Hermite J, Peray P, Saissi G, Coussaye JE de la, Eledjam JJ (2000) Insertion time of the pulmonary artery catheter in critically ill patients. Crit Care Med 28:355–359PubMed
33.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M (1999) Intraoperative volume expansion guided by esophageal Doppler improves postoperative outcome and shortens hospital stay. Anesthesiology 91:A537 Gan TJ, Soppitt A, Maroof M (1999) Intraoperative volume expansion guided by esophageal Doppler improves postoperative outcome and shortens hospital stay. Anesthesiology 91:A537
34.
Zurück zum Zitat Baillard C, Cohen Y, Fosse JP, Karoubi P, Hoang P, Cupa M (1999) Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: transoesophageal Doppler versus continuous thermodilution. Anaesth Intensive Care 27:33–37PubMed Baillard C, Cohen Y, Fosse JP, Karoubi P, Hoang P, Cupa M (1999) Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: transoesophageal Doppler versus continuous thermodilution. Anaesth Intensive Care 27:33–37PubMed
35.
Zurück zum Zitat Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072PubMed Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072PubMed
Metadaten
Titel
Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler
verfasst von
Margareta Roeck
Stephan M. Jakob
Thomas Boehlen
Lukas Brander
Rafael Knuesel
Jukka Takala
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 10/2003
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-003-1720-4

Weitere Artikel der Ausgabe 10/2003

Intensive Care Medicine 10/2003 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.