Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
verfasst von:
Christophe Barbier, Yann Loubières, Christophe Schmit, Jan Hayon, Jean-Louis Ricôme, François Jardin, Antoine Vieillard-Baron
Erschienen in:
Intensive Care Medicine
|
Ausgabe 9/2004
Einloggen, um Zugang zu erhalten
Abstract
Objective
To evaluate the extent to which respiratory changes in inferior vena cava (IVC) diameter can be used to predict fluid responsiveness.
Design
Prospective clinical study.
Setting
Hospital intensive care unit.
Patients
Twenty-three patients with acute circulatory failure related to sepsis and mechanically ventilated because of an acute lung injury.
Measurements
Inferior vena cava diameter (D) at end-expiration (Dmin) and at end-inspiration (Dmax) was measured by echocardiography using a subcostal approach. The distensibility index of the IVC (dIVC) was calculated as the ratio of Dmax − Dmin / Dmin, and expressed as a percentage. The Doppler technique was applied in the pulmonary artery trunk to determine cardiac index (CI). Measurements were performed at baseline and after a 7 ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in CI ≥15%) and non-responders (increase in CI <15%).
Results
Using a threshold dIVC of 18%, responders and non-responders were discriminated with 90% sensitivity and 90% specificity. A strong relation (r=0.9) was observed between dIVC at baseline and the CI increase following blood volume expansion. Baseline central venous pressure did not accurately predict fluid responsiveness.
Conclusion
Our study suggests that respiratory change in IVC diameter is an accurate predictor of fluid responsiveness in septic patients.