Skip to main content
Erschienen in: Intensive Care Medicine 9/2009

01.09.2009 | Brief Report

Is proportional-assist ventilation with load-adjustable gain factors a user-friendly mode?

verfasst von: Nectaria Xirouchaki, Eumorfia Kondili, Maria Klimathianaki, Dimitris Georgopoulos

Erschienen in: Intensive Care Medicine | Ausgabe 9/2009

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of this study was to compare the number of interventions (ventilator settings and sedatives, analgesics and vasoactive medication dose manipulations) between critically ill patients on proportional-assist ventilation with load-adjustable gain factors (PAV+) and those on pressure support (PS).

Design

Retrospective analysis of data from a previous randomized clinical trial.

Methods

A total of 208 patients who were mechanically ventilated on controlled modes and met criteria for assisted breathing were randomized to receive either PS (n = 100) or PAV+ (n = 108). Changes in ventilator settings and in the dose of sedatives, analgesics, and vasoactive medications were identified during the period in which the patients were ventilated either with PS (30.4 ± 17.4 h) or PAV+ (30.0 ± 18.1 h) and classified as changes to facilitate weaning (CFW) or changes to respond to deterioration (CD).

Results

The mean number of changes in ventilator settings was significantly higher with PS than that with PAV+ (10.7 ± 5.7 vs. 8.9 ± 4.6). With PS the proportion of these changes classified as CFW was significantly lower than that with PAV+ (59.8% vs. 69.2%). Dyssynchrony as a cause of CD was more likely to occur with PS than with PAV+ (42 vs. 3%). The mean number of changes in the dose of sedatives, analgesics, and vasoactive medications was higher with PS than with PAV+, the difference being significant only for sedatives (4.06 ± 3.8 vs. 2.82 ± 3.4).

Conclusions

Compared to PS, PAV+ is associated with fewer intervention in terms of ventilator settings and sedative dose changes.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Younes M (1992) Proportional assist ventilation, a new approach to ventilatory support: theory. Am Rev Respir Dis 145:114–120PubMed Younes M (1992) Proportional assist ventilation, a new approach to ventilatory support: theory. Am Rev Respir Dis 145:114–120PubMed
2.
Zurück zum Zitat Kondili E, Prinianakis G, Alexopoulou C, Vakouti E, Klimathianaki M, Georgopoulos D (2006) Respiratory load compensation during mechanical ventilation—proportional assist ventilation with load-adjustable gain factors versus pressure support. Intensive Care Med 32:692–699PubMedCrossRef Kondili E, Prinianakis G, Alexopoulou C, Vakouti E, Klimathianaki M, Georgopoulos D (2006) Respiratory load compensation during mechanical ventilation—proportional assist ventilation with load-adjustable gain factors versus pressure support. Intensive Care Med 32:692–699PubMedCrossRef
3.
Zurück zum Zitat Younes M, Kun J, Masiowski B, Webster K, Roberts D (2001) A method for noninvasive determination of inspiratory resistance during proportional assist ventilation. Am J Respir Crit Care Med 163:829–839PubMed Younes M, Kun J, Masiowski B, Webster K, Roberts D (2001) A method for noninvasive determination of inspiratory resistance during proportional assist ventilation. Am J Respir Crit Care Med 163:829–839PubMed
4.
Zurück zum Zitat Younes M, Webster K, Kun J, Roberts D, Masiowski B (2001) A method for measuring passive elastance during proportional assist ventilation. Am J Respir Crit Care Med 164:50–60PubMed Younes M, Webster K, Kun J, Roberts D, Masiowski B (2001) A method for measuring passive elastance during proportional assist ventilation. Am J Respir Crit Care Med 164:50–60PubMed
5.
Zurück zum Zitat Xirouchaki N, Kondili E, Vaporidi K, Xirouchakis G, Klimathianaki M, Gavriilidis G, Alexandopoulou E, Plataki M, Alexopoulou C, Georgopoulos D (2008) Proportional assist ventilation with load-adjustable gain factors in critically ill patients: comparison with pressure support. Intensive Care Med 34:2026–2034PubMedCrossRef Xirouchaki N, Kondili E, Vaporidi K, Xirouchakis G, Klimathianaki M, Gavriilidis G, Alexandopoulou E, Plataki M, Alexopoulou C, Georgopoulos D (2008) Proportional assist ventilation with load-adjustable gain factors in critically ill patients: comparison with pressure support. Intensive Care Med 34:2026–2034PubMedCrossRef
6.
Zurück zum Zitat Tassaux D, Gainnier M, Battisti A, Jolliet P (2005) Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. Am J Respir Crit Care Med 172:1283–1289PubMedCrossRef Tassaux D, Gainnier M, Battisti A, Jolliet P (2005) Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. Am J Respir Crit Care Med 172:1283–1289PubMedCrossRef
7.
Zurück zum Zitat Bonmarchand G, Chevron V, Menard JF, Girault C, Moritz-Berthelot F, Pasquis P, Leroy J (1999) Effects of pressure ramp slope values on the work of breathing during pressure support ventilation in restrictive patients. Crit Care Med 27:715–722PubMedCrossRef Bonmarchand G, Chevron V, Menard JF, Girault C, Moritz-Berthelot F, Pasquis P, Leroy J (1999) Effects of pressure ramp slope values on the work of breathing during pressure support ventilation in restrictive patients. Crit Care Med 27:715–722PubMedCrossRef
8.
Zurück zum Zitat Kress JP, Hall JB (2006) Sedation in the mechanically ventilated patient. Crit Care Med 34:2541–2546PubMedCrossRef Kress JP, Hall JB (2006) Sedation in the mechanically ventilated patient. Crit Care Med 34:2541–2546PubMedCrossRef
9.
Zurück zum Zitat Kress JP, Pohlman AS, O’Connor MF, Hall JB (2000) Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 342:1471–1477PubMedCrossRef Kress JP, Pohlman AS, O’Connor MF, Hall JB (2000) Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 342:1471–1477PubMedCrossRef
10.
Zurück zum Zitat Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R, Calandra T, Dhainaut JF, Gerlach H, Harvey M, Marini JJ, Marshall J, Ranieri M, Ramsay G, Sevransky J, Thompson BT, Townsend S, Vender JS, Zimmerman JL, Vincent JL (2008) Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med 36:296–327PubMedCrossRef Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R, Calandra T, Dhainaut JF, Gerlach H, Harvey M, Marini JJ, Marshall J, Ranieri M, Ramsay G, Sevransky J, Thompson BT, Townsend S, Vender JS, Zimmerman JL, Vincent JL (2008) Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med 36:296–327PubMedCrossRef
11.
Zurück zum Zitat Thille AW, Cabello B, Galia F, Lyazidi A, Brochard L (2008) Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation. Intensive Care Med 34:1477–1486PubMedCrossRef Thille AW, Cabello B, Galia F, Lyazidi A, Brochard L (2008) Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation. Intensive Care Med 34:1477–1486PubMedCrossRef
12.
Zurück zum Zitat Thille AW, Rodriguez P, Cabello B, Lellouche F, Brochard L (2006) Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 32:1515–1522PubMedCrossRef Thille AW, Rodriguez P, Cabello B, Lellouche F, Brochard L (2006) Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 32:1515–1522PubMedCrossRef
13.
Zurück zum Zitat Mitrouska J, Xirouchaki N, Patakas D, Siafakas N, Georgopoulos D (1999) Effects of chemical feedback on respiratory motor and ventilatory output during different modes of assisted mechanical ventilation. Eur Respir J 13:873–882PubMedCrossRef Mitrouska J, Xirouchaki N, Patakas D, Siafakas N, Georgopoulos D (1999) Effects of chemical feedback on respiratory motor and ventilatory output during different modes of assisted mechanical ventilation. Eur Respir J 13:873–882PubMedCrossRef
14.
Zurück zum Zitat Giannouli E, Webster K, Roberts D, Younes M (1999) Response of ventilator-dependent patients to different levels of pressure support and proportional assist. Am J Respir Crit Care Med 159:1716–1725PubMed Giannouli E, Webster K, Roberts D, Younes M (1999) Response of ventilator-dependent patients to different levels of pressure support and proportional assist. Am J Respir Crit Care Med 159:1716–1725PubMed
15.
Zurück zum Zitat Vignaux L, Vargas F, Roeseler J, Tassaux D, Thille AW, Kossowsky MP, Brochard L, Jolliet P (2009) Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study. Intensive Care Med 35:840–846PubMedCrossRef Vignaux L, Vargas F, Roeseler J, Tassaux D, Thille AW, Kossowsky MP, Brochard L, Jolliet P (2009) Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study. Intensive Care Med 35:840–846PubMedCrossRef
16.
Zurück zum Zitat Bosma K, Ferreyra G, Ambrogio C, Pasero D, Mirabella L, Braghiroli A, Appendini L, Mascia L, Ranieri VM (2007) Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation. Crit Care Med 35:1048–1054PubMedCrossRef Bosma K, Ferreyra G, Ambrogio C, Pasero D, Mirabella L, Braghiroli A, Appendini L, Mascia L, Ranieri VM (2007) Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation. Crit Care Med 35:1048–1054PubMedCrossRef
Metadaten
Titel
Is proportional-assist ventilation with load-adjustable gain factors a user-friendly mode?
verfasst von
Nectaria Xirouchaki
Eumorfia Kondili
Maria Klimathianaki
Dimitris Georgopoulos
Publikationsdatum
01.09.2009
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 9/2009
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-009-1524-2

Weitere Artikel der Ausgabe 9/2009

Intensive Care Medicine 9/2009 Zur Ausgabe

Correspondence

Reply to Gibot

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.