Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema

verfasst von: Alexis Ferré, Max Guillot, Daniel Lichtenstein, Gilbert Mezière, Christian Richard, Jean-Louis Teboul, Xavier Monnet

Erschienen in: Intensive Care Medicine | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Rationale

Detecting weaning-induced pulmonary oedema (WIPO) is important because its treatment might prompt extubation. For this purpose, lung ultrasound might be an attractive tool, since it demonstrates pulmonary oedema through the appearance of B-lines.

Objectives

To test the ideal profile (increase in the number of B-lines) for diagnosing WIPO.

Methods

Before and at the end of 62 spontaneous breathing trials (SBT) performed in 42 patients, we prospectively assessed lung ultrasound on four anterior chest wall points. B-lines were counted before and at the end of SBT. We looked for the threshold of B-line increase (Delta-B-lines) that provided the best diagnostic accuracy, compared to the reference diagnosis of WIPO established by experts blinded to lung ultrasound.

Results

SBT failed in 33 cases. WIPO occurred in 17 cases and all failed. The best diagnostic accuracy was reached with a Delta-B-lines ≥ 6. Among WIPO, the number of B-lines increased by ≥ 6 in 15 cases (including 13 cases with an increase of ≥ 8 B-lines). Among the 16 cases with SBT failure but without WIPO, the Delta-B-lines was ≥ 6 in two cases. Among the 33 cases with SBT failure, this profile diagnosed WIPO with a sensitivity of 88% (64–98) and a specificity of 88% (62–98) [area under the receiver operating characteristic curve 0.91 (0.75–0.98)]. Among the 29 cases with SBT success, a Delta-B-lines ≥ 6 occurred in two cases.

Conclusions

This study suggests that a Delta-B-lines ≥  6 on four anterior points allows the diagnosis of WIPO with the best accuracy. This should be confirmed in larger populations.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
3.
Zurück zum Zitat Lemaire F, Teboul JL, Cinotti L et al (1988) Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation. Anesthesiology 69:171–179CrossRefPubMed Lemaire F, Teboul JL, Cinotti L et al (1988) Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation. Anesthesiology 69:171–179CrossRefPubMed
10.
Zurück zum Zitat Lichtenstein D (1994) Ultrasound diagnosis of pulmonary edema. Rev Im Med 6:561–562 Lichtenstein D (1994) Ultrasound diagnosis of pulmonary edema. Rev Im Med 6:561–562
20.
Zurück zum Zitat Lichtenstein D, Mezière G (2011) The BLUE-points: three standardized points used in the BLUE-protocol for ultrasound assessment of the lung in acute respiratory failure. Crit Ultrasound J 3:109–110CrossRef Lichtenstein D, Mezière G (2011) The BLUE-points: three standardized points used in the BLUE-protocol for ultrasound assessment of the lung in acute respiratory failure. Crit Ultrasound J 3:109–110CrossRef
27.
Zurück zum Zitat Figueras J, Weil MH (1978) Blood volume prior to and following treatment of acute cardiogenic pulmonary edema. Circulation 57:349–355CrossRefPubMed Figueras J, Weil MH (1978) Blood volume prior to and following treatment of acute cardiogenic pulmonary edema. Circulation 57:349–355CrossRefPubMed
Metadaten
Titel
Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema
verfasst von
Alexis Ferré
Max Guillot
Daniel Lichtenstein
Gilbert Mezière
Christian Richard
Jean-Louis Teboul
Xavier Monnet
Publikationsdatum
12.03.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Intensive Care Medicine / Ausgabe 5/2019
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-019-05573-6

Weitere Artikel der Ausgabe 5/2019

Intensive Care Medicine 5/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.