Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2004

01.09.2004 | Experimental Study

Optimal screw diameter for interference fixation in a bone tunnel: a porcine model

verfasst von: M. W. J. Morris, J. L. Williams, A. J. Thake, Y. Lang, J. N. Brown

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 5/2004

Einloggen, um Zugang zu erhalten

Abstract

The study investigates the optimal interference screw dimensions required to secure a tendon graft in a bone tunnel. A standard 8 mm pig flexor-tendon graft was inserted into a standard open-ended 8 mm bone tunnel of a porcine distal femur and secured using either 7 mm, 8 mm or 9 mm diameter metal interference screws (Arthrex Inc, Naples, FL). The construct was tested to failure using a Shimadzu ASG 10KN Universal Material Testing Machine (Shimadzu, Tokyo, Japan). Load and mode of construct failure were recorded for 37 individual constructs. There was no significant difference in the load at failure between the 7 mm screw (192 N; range 151–232) and 8 mm screw (181 N; range 150–212) (p>0.05). There was a significant difference between the 7 mm screw and the 9 mm screw (109 N; range 67–151) (p=0.006) and between the 8 mm screw and the 9 mm screw (p=0.015). When using a 9 mm screw, 100% of the constructs failed by cut out of the graft at the tunnel opening. The 7 mm constructs failed by slippage of the tendon from the bone tunnel in 83% of cases, with only 17% failing by cut out at the tunnel opening. The 8 mm constructs demonstrated a mixture of failure modes, with slippage occurring in 58% of cases, cut out in 38% and failure of the graft substance in one case (4%). In this model, screw diameters equal to or 1 mm less than the tunnel/tendon diameter provides better fixation than using a screw 1 mm larger. The mode of failure differs for each of these screws.
Literatur
1.
Zurück zum Zitat Allen AD, Sitler R, Marchetto P, Kelly JD, Mattacola CG (2001) Assessment of the endoscopic semitendinosus/gracilis autograft procedure with interference screw fixation for reconstruction of the anterior cruciate ligament. Orthopedics 24:347–353CrossRefPubMed Allen AD, Sitler R, Marchetto P, Kelly JD, Mattacola CG (2001) Assessment of the endoscopic semitendinosus/gracilis autograft procedure with interference screw fixation for reconstruction of the anterior cruciate ligament. Orthopedics 24:347–353CrossRefPubMed
2.
3.
Zurück zum Zitat Brand J, Weiler A, Carbon DNM, Brown CH, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–773PubMed Brand J, Weiler A, Carbon DNM, Brown CH, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–773PubMed
4.
Zurück zum Zitat Bickerstaff D (2001) BASK Instructional Lecture 4: anterior cruciate ligament graft fixation. Knee 8:79–81CrossRefPubMed Bickerstaff D (2001) BASK Instructional Lecture 4: anterior cruciate ligament graft fixation. Knee 8:79–81CrossRefPubMed
5.
Zurück zum Zitat Brown CH, Hecker AT, Hipp JA, Myers ER, Hayes WC (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed Brown CH, Hecker AT, Hipp JA, Myers ER, Hayes WC (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed
6.
Zurück zum Zitat Brown GA, Pena F, Grontvedt T, Labadie D, Engebretsen L (1996) Fixation strength of interference screw fixation in bovine, young human and elderly human cadaver knees: influence of insertion torque, tunnel–bone gap and interference. Knee Surg Sports Traumatol Arthrosc 3:238–244PubMed Brown GA, Pena F, Grontvedt T, Labadie D, Engebretsen L (1996) Fixation strength of interference screw fixation in bovine, young human and elderly human cadaver knees: influence of insertion torque, tunnel–bone gap and interference. Knee Surg Sports Traumatol Arthrosc 3:238–244PubMed
7.
Zurück zum Zitat Caborn DN, Coen M, Neef R, Hamilton D, Nyland J, Johnson DL (1998) Quadrupled semitendinosus–gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw. Arthroscopy 14:241–245PubMed Caborn DN, Coen M, Neef R, Hamilton D, Nyland J, Johnson DL (1998) Quadrupled semitendinosus–gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw. Arthroscopy 14:241–245PubMed
8.
Zurück zum Zitat Carbon DN, Selby JB (2002) Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction. Arthroscopy 18:102–105CrossRefPubMed Carbon DN, Selby JB (2002) Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction. Arthroscopy 18:102–105CrossRefPubMed
9.
Zurück zum Zitat Carter TR, Edinger S (1999) Isokinetic evaluation of anterior cruciate ligament reconstruction: hamstring versus patellar tendon. Arthroscopy 15:169–172PubMed Carter TR, Edinger S (1999) Isokinetic evaluation of anterior cruciate ligament reconstruction: hamstring versus patellar tendon. Arthroscopy 15:169–172PubMed
10.
Zurück zum Zitat Casteleyn PP (1999) Management of anterior cruciate ligament lesions: surgical fashion, personal whim or scientific evidence? Study of medium- and long-term results. Acta Orthop Belg 65:327–339PubMed Casteleyn PP (1999) Management of anterior cruciate ligament lesions: surgical fashion, personal whim or scientific evidence? Study of medium- and long-term results. Acta Orthop Belg 65:327–339PubMed
11.
Zurück zum Zitat Clancey WG, Narechania RG, Rosenberg TD Gmeiner JG, Wisnefske DD, Lange TA (1981)Anterior and posterior cruciate ligament reconstructions in rhesus monkeys. A histological microangiographic and biomechanical analysis. J Bone Joint Surg Am 63:1270–1284PubMed Clancey WG, Narechania RG, Rosenberg TD Gmeiner JG, Wisnefske DD, Lange TA (1981)Anterior and posterior cruciate ligament reconstructions in rhesus monkeys. A histological microangiographic and biomechanical analysis. J Bone Joint Surg Am 63:1270–1284PubMed
12.
Zurück zum Zitat Cuppone M, Seedhom BB (2001) Effect of implant lengthening and mode of fixation on knee laxity after ACL reconstruction with an artificial ligament: a cadaveric study. J Orthop Sci 6:253–261CrossRefPubMed Cuppone M, Seedhom BB (2001) Effect of implant lengthening and mode of fixation on knee laxity after ACL reconstruction with an artificial ligament: a cadaveric study. J Orthop Sci 6:253–261CrossRefPubMed
13.
Zurück zum Zitat Dyson L, Hamner MD, Brown CH, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the ACL: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed Dyson L, Hamner MD, Brown CH, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the ACL: biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed
14.
Zurück zum Zitat Francis A, Thomas R de WM, McGregor A (2001) Anterior cruciate ligament rupture: reconstruction surgery and rehabilitation. A nation-wide survey of current practice. Knee 8:13–18CrossRefPubMed Francis A, Thomas R de WM, McGregor A (2001) Anterior cruciate ligament rupture: reconstruction surgery and rehabilitation. A nation-wide survey of current practice. Knee 8:13–18CrossRefPubMed
16.
Zurück zum Zitat Khon D, Sander-Beuermann A (1994) Donor site morbidity after harvest of a bone–tendon–bone patellar tendon autograft. Arthroscopy 2:219–223 Khon D, Sander-Beuermann A (1994) Donor site morbidity after harvest of a bone–tendon–bone patellar tendon autograft. Arthroscopy 2:219–223
17.
Zurück zum Zitat Kousa P, Jarvinen TL, Kannus P, Jarvinen M (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed Kousa P, Jarvinen TL, Kannus P, Jarvinen M (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed
18.
Zurück zum Zitat Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed
19.
Zurück zum Zitat Noyes FR, Butler DL, Grood ES, Zernicke RF, Hefzy MS (1984) Biomechanical analysis of human ligament grafts used in knee ligament repairs and reconstructions. J Bone Joint Surg Am 66:344–352PubMed Noyes FR, Butler DL, Grood ES, Zernicke RF, Hefzy MS (1984) Biomechanical analysis of human ligament grafts used in knee ligament repairs and reconstructions. J Bone Joint Surg Am 66:344–352PubMed
20.
Zurück zum Zitat Robert Larson, Mario Taillon (1994) Anterior cruciate ligament insufficiency: principles of treatment. J Am Acad Orthop Surg 2:26–35PubMed Robert Larson, Mario Taillon (1994) Anterior cruciate ligament insufficiency: principles of treatment. J Am Acad Orthop Surg 2:26–35PubMed
21.
Zurück zum Zitat Rowden NJ, Sher D, Rogers GJ, Shindhelm K (1997) Anterior cruciate ligament graft fixation. Initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers. Am J Sports Med 25:472–478PubMed Rowden NJ, Sher D, Rogers GJ, Shindhelm K (1997) Anterior cruciate ligament graft fixation. Initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers. Am J Sports Med 25:472–478PubMed
22.
Zurück zum Zitat Selby JB, Johnson DL, Hester P, Carbon DNM (2001) Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am J Sports Med 29:614–619PubMed Selby JB, Johnson DL, Hester P, Carbon DNM (2001) Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am J Sports Med 29:614–619PubMed
23.
Zurück zum Zitat Stadelmaier DM, Lowe WR, Ilahi OA, Noble PC, Kohl HW (1999) Cyclic pullout strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length. Am J Sports Med 27:778–783PubMed Stadelmaier DM, Lowe WR, Ilahi OA, Noble PC, Kohl HW (1999) Cyclic pullout strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length. Am J Sports Med 27:778–783PubMed
24.
Zurück zum Zitat Vergis A, Gillquist J (1995) Graft failure in intraarticular anterior cruciate ligament reconstructions: a review of the literature. Arthroscopy 11:312–321PubMed Vergis A, Gillquist J (1995) Graft failure in intraarticular anterior cruciate ligament reconstructions: a review of the literature. Arthroscopy 11:312–321PubMed
25.
Zurück zum Zitat Weiler A, Hoffmann RF, Siepe CJ, Kolback SF, Sudkamp NP (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed Weiler A, Hoffmann RF, Siepe CJ, Kolback SF, Sudkamp NP (2000) The influence of screw geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356–359PubMed
26.
Zurück zum Zitat Witvrouw E, Bellemans J, Verdonk R, Cambier D, Coorevits P Almqvist F (2001) Patellar tendon vs doubled semitendinosus and gracilis tendon for anterior cruciate ligament reconstruction. Int Orthop 25:308–311CrossRefPubMed Witvrouw E, Bellemans J, Verdonk R, Cambier D, Coorevits P Almqvist F (2001) Patellar tendon vs doubled semitendinosus and gracilis tendon for anterior cruciate ligament reconstruction. Int Orthop 25:308–311CrossRefPubMed
27.
Zurück zum Zitat Yasuda K, Tsujino J, Ohkoshi Y, Tanabe Y, Kaneda K (1995) Graft site morbidity with autogenous semitendinosus and gracilis tendons. Am J Sports Med 23:706–714PubMed Yasuda K, Tsujino J, Ohkoshi Y, Tanabe Y, Kaneda K (1995) Graft site morbidity with autogenous semitendinosus and gracilis tendons. Am J Sports Med 23:706–714PubMed
Metadaten
Titel
Optimal screw diameter for interference fixation in a bone tunnel: a porcine model
verfasst von
M. W. J. Morris
J. L. Williams
A. J. Thake
Y. Lang
J. N. Brown
Publikationsdatum
01.09.2004
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 5/2004
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-003-0466-4

Weitere Artikel der Ausgabe 5/2004

Knee Surgery, Sports Traumatology, Arthroscopy 5/2004 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.