Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2007

01.08.2007 | Knee

Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies

verfasst von: D. Kendoff, M. Citak, A. Pearle, M. J. Gardner, S. Hankemeier, C. Krettek, T. Hüfner

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 8/2007

Einloggen, um Zugang zu erhalten

Abstract

Inaccurate coronal plane realignment is a common problem after high tibial osteotomy. It has been shown that lower limb rotation has an effect on the two-dimensional measurement of lower limb alignment. Although alignment errors are known to occur due to limb rotation, the magnitude of this effect is unknown. Navigation systems allow for the measurments of coronal plane alignment and dynamically rotational and sagittal plane. Our study evaluated the effect of rotational leg movements on coronal plane alignment as determined by image-free navigation. We hypothesized that a linear relationship exists between rotation and angular measurements. Eight cadavers were used, while three test conditions of the complete lower limbs were established: (1) solid knee arthrodesis, (2) provisional knee arthrodesis and (3) unconstrained knee conditions. Navigated measurements of coronal and sagittal lower limb axis were done initially without knee flexion for defined internal/external rotations of 5°, 10° and maximal values for all test series. Repeated test for the unconstrained knee included stepwise knee flexion of 5°, 10° and 20°. Statistical analysis comparing the test conditions 1, 2 and 3 and comparison between flexion movements of the unconstrained knee were done. Results revealed no significant differences between the different rotations of test condition 1 (mean 0.34°, SD 0.23, range, 0°–0.8°). Condition 2 similarly did not result in significant deviations (mean 0.51°, SD 0.24, range 0.1°–0.9°). Measurement deviations ranging from 0.4° to 4.3° were found for condition 3, the unconstrained knee. However, no statistically different testings from the arthrodesed knee were found (P = 0.099–0.410). Knee flexion from 5°, 10° or 20°, showed significant deviations (P < 0.05) for all rotations at all degrees of flexion. Rotation and flexion of 5° led to significant alignment errors of 3.4° and 2.8°, respectively, for internal and external rotations. Measurement failures due to the rotational movements of 1°–4° might add to additional sources of errors causing relevant under- or overcorrections of the mechanical leg axis. Discrepancies of the axis due to rotational movements as well as flexion of the knee joint can be avoided and corrected immediately with the help of navigation.
Literatur
1.
Zurück zum Zitat Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005): Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005): Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef
2.
Zurück zum Zitat Hankemeier S, Zheng G, Wang G, Zeichen J, Hüfner T, Krettek C (2005) Navigated open wedge high tibia osteotomy: advantages and disadvantages in comparison to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc accepted Hankemeier S, Zheng G, Wang G, Zeichen J, Hüfner T, Krettek C (2005) Navigated open wedge high tibia osteotomy: advantages and disadvantages in comparison to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc accepted
3.
Zurück zum Zitat Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed
4.
Zurück zum Zitat Kawakami H, Sugano N, Yonenobu K, Yoshikawa H, Ochi T, Hattori A, Suzuki N (2004) Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Orthop Res 22:1248–1253PubMedCrossRef Kawakami H, Sugano N, Yonenobu K, Yoshikawa H, Ochi T, Hattori A, Suzuki N (2004) Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Orthop Res 22:1248–1253PubMedCrossRef
5.
Zurück zum Zitat Keppler P, Gebhard F, Grutzner PA, Wang G, Zheng G, Hufner T, Hankemeier S, Nolte LP (2004) Computer aided high tibial open wedge osteotomy. Injury 35(Suppl 1):S-A68–S-A78 Keppler P, Gebhard F, Grutzner PA, Wang G, Zheng G, Hufner T, Hankemeier S, Nolte LP (2004) Computer aided high tibial open wedge osteotomy. Injury 35(Suppl 1):S-A68–S-A78
6.
Zurück zum Zitat Keppler P, Suger G, Kinzl L, Strecker W (2002) Osteotomies in malalignments of the lower extremities. Chirurg 73:982–989PubMedCrossRef Keppler P, Suger G, Kinzl L, Strecker W (2002) Osteotomies in malalignments of the lower extremities. Chirurg 73:982–989PubMedCrossRef
7.
Zurück zum Zitat Khadem R, Yeh CC, Sadeghi-Tehrani M, Bax MR, Johnson JA, Welch JN, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107PubMedCrossRef Khadem R, Yeh CC, Sadeghi-Tehrani M, Bax MR, Johnson JA, Welch JN, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107PubMedCrossRef
8.
Zurück zum Zitat Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 29(Suppl 3):C29–C39PubMedCrossRef Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 29(Suppl 3):C29–C39PubMedCrossRef
9.
Zurück zum Zitat Li Q, Zamorano L, Jiang Z, Gong JX, Pandya A, Perez R, Diaz F (1999) Effect of optical digitizer selection on the application accuracy of a surgical localization system—a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. Comput Aided Surg 4:314–321PubMedCrossRef Li Q, Zamorano L, Jiang Z, Gong JX, Pandya A, Perez R, Diaz F (1999) Effect of optical digitizer selection on the application accuracy of a surgical localization system—a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. Comput Aided Surg 4:314–321PubMedCrossRef
10.
Zurück zum Zitat Marti CB, Gautier E, Wachtl SW, Jakob RP (2004) Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 20:366–372PubMedCrossRef Marti CB, Gautier E, Wachtl SW, Jakob RP (2004) Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 20:366–372PubMedCrossRef
11.
Zurück zum Zitat Matthews LS, Goldstein SA, Malvitz TA, Katz BP, Kaufer H (1988) Proximal tibial osteotomy. Factors that influence the duration of satisfactory function. Clin Orthop Relat Res 229:193–200PubMed Matthews LS, Goldstein SA, Malvitz TA, Katz BP, Kaufer H (1988) Proximal tibial osteotomy. Factors that influence the duration of satisfactory function. Clin Orthop Relat Res 229:193–200PubMed
12.
Zurück zum Zitat Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25:425–465PubMed Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25:425–465PubMed
13.
Zurück zum Zitat Paley D, Maar DC, Herzenberg JE (1994) New concepts in high tibial osteotomy for medial compartment osteoarthritis. Orthop Clin North Am 25:483–498PubMed Paley D, Maar DC, Herzenberg JE (1994) New concepts in high tibial osteotomy for medial compartment osteoarthritis. Orthop Clin North Am 25:483–498PubMed
14.
Zurück zum Zitat Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed
15.
Zurück zum Zitat Papachristou G (2004) Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy. Arch Orthop Trauma Surg 124:288–297PubMedCrossRef Papachristou G (2004) Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy. Arch Orthop Trauma Surg 124:288–297PubMedCrossRef
16.
Zurück zum Zitat Pape D, Seil R, Adam F, Rupp S, Kohn D, Lobenhoffer P (2004) Imaging and preoperative planning of osteotomy of tibial head osteotomy. Orthopade 33:122–134PubMedCrossRef Pape D, Seil R, Adam F, Rupp S, Kohn D, Lobenhoffer P (2004) Imaging and preoperative planning of osteotomy of tibial head osteotomy. Orthopade 33:122–134PubMedCrossRef
17.
Zurück zum Zitat Prix R (2005) Opening-wedge osteotomy of the proximal tibia. Acta Chir Orthop Traumatol Cech 72:308–312PubMed Prix R (2005) Opening-wedge osteotomy of the proximal tibia. Acta Chir Orthop Traumatol Cech 72:308–312PubMed
18.
Zurück zum Zitat Saleh M, Harriman P, Edwards DJ (1991) A radiological method for producing precise limb alignment. J Bone Joint Surg Br 73:515–516PubMed Saleh M, Harriman P, Edwards DJ (1991) A radiological method for producing precise limb alignment. J Bone Joint Surg Br 73:515–516PubMed
19.
Zurück zum Zitat Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–s1274PubMed Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–s1274PubMed
20.
Zurück zum Zitat Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am 85–A:469–474PubMed Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am 85–A:469–474PubMed
21.
Zurück zum Zitat Wang G, Zheng G, Gruetzner PA, Mueller-Alsbach U, von Recum J, Staubli A, Nolte LP (2005) A fluoroscopy-based surgical navigation system for high tibial osteotomy. Technol Health Care 13:469–483PubMed Wang G, Zheng G, Gruetzner PA, Mueller-Alsbach U, von Recum J, Staubli A, Nolte LP (2005) A fluoroscopy-based surgical navigation system for high tibial osteotomy. Technol Health Care 13:469–483PubMed
22.
Zurück zum Zitat Wang G, Zheng G, Keppler P, Gebhard F, Staubli A, Mueller U, Schmucki D, Fluetsch S, Nolte LP (2005) Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy. Comput Aided Surg 10:73–86PubMedCrossRef Wang G, Zheng G, Keppler P, Gebhard F, Staubli A, Mueller U, Schmucki D, Fluetsch S, Nolte LP (2005) Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy. Comput Aided Surg 10:73–86PubMedCrossRef
Metadaten
Titel
Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies
verfasst von
D. Kendoff
M. Citak
A. Pearle
M. J. Gardner
S. Hankemeier
C. Krettek
T. Hüfner
Publikationsdatum
01.08.2007
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 8/2007
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-007-0308-x

Weitere Artikel der Ausgabe 8/2007

Knee Surgery, Sports Traumatology, Arthroscopy 8/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.