Abstract

SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0–10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3° (range 0°–6°). The median intra-observer variability for these was less than 2° (range 0°–5°). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated.
Literatur
1.
Zurück zum Zitat Agriantonis DJ, Hall L, Wilson MA (2009) Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med 34:247–248CrossRefPubMed Agriantonis DJ, Hall L, Wilson MA (2009) Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med 34:247–248CrossRefPubMed
2.
Zurück zum Zitat Bailey E, HoShon I, Roach P (2007) Additional benefit of SPECT/CT in bone scanning of metastatic renal cell carcinoma. Clin Nucl Med 32:411–414CrossRefPubMed Bailey E, HoShon I, Roach P (2007) Additional benefit of SPECT/CT in bone scanning of metastatic renal cell carcinoma. Clin Nucl Med 32:411–414CrossRefPubMed
3.
Zurück zum Zitat Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRefPubMed Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRefPubMed
4.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRefPubMed Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRefPubMed
5.
Zurück zum Zitat Bockisch A, Freudenberg LS, Schmidt D, Kuwert T (2009) Hybrid imaging by SPECT/CT and PET/CT: proven outcomes in cancer imaging. Semin Nucl Med 39:276–289CrossRefPubMed Bockisch A, Freudenberg LS, Schmidt D, Kuwert T (2009) Hybrid imaging by SPECT/CT and PET/CT: proven outcomes in cancer imaging. Semin Nucl Med 39:276–289CrossRefPubMed
6.
Zurück zum Zitat Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M et al (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706CrossRefPubMed Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M et al (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706CrossRefPubMed
7.
Zurück zum Zitat Bruni C, Padovano F, Travascio L, Schillaci O, Simonetti G (2008) Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis. Braz J Infect Dis 12:558–560CrossRefPubMed Bruni C, Padovano F, Travascio L, Schillaci O, Simonetti G (2008) Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis. Braz J Infect Dis 12:558–560CrossRefPubMed
8.
Zurück zum Zitat Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD (2008) SPECT/CT imaging: clinical utility of an emerging technology. Radiographics 28:1097–1113CrossRefPubMed Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD (2008) SPECT/CT imaging: clinical utility of an emerging technology. Radiographics 28:1097–1113CrossRefPubMed
9.
Zurück zum Zitat Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed
10.
Zurück zum Zitat Chowdhury FU, Scarsbrook AF (2008) The role of hybrid SPECT-CT in oncology: current and emerging clinical applications. Clin Radiol 63:241–251CrossRefPubMed Chowdhury FU, Scarsbrook AF (2008) The role of hybrid SPECT-CT in oncology: current and emerging clinical applications. Clin Radiol 63:241–251CrossRefPubMed
11.
Zurück zum Zitat d‘ Amico A, Szczucka K, Borys D, Gorczewski K, Steinhof K (2006) SPECT-CT fusion a new diagnostic tool for endocrinology. Endokrynol Pol 57(Suppl A):71–74 d‘ Amico A, Szczucka K, Borys D, Gorczewski K, Steinhof K (2006) SPECT-CT fusion a new diagnostic tool for endocrinology. Endokrynol Pol 57(Suppl A):71–74
12.
Zurück zum Zitat Filippi L, Uccioli L, Giurato L, Schillaci O (2009) Diabetic foot infection: usefulness of SPECT/CT for 99mTc-HMPAO-labeled leukocyte imaging. J Nucl Med 50:1042–1046CrossRefPubMed Filippi L, Uccioli L, Giurato L, Schillaci O (2009) Diabetic foot infection: usefulness of SPECT/CT for 99mTc-HMPAO-labeled leukocyte imaging. J Nucl Med 50:1042–1046CrossRefPubMed
13.
Zurück zum Zitat Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR et al (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. Bone Joint Surg Br 88:1513–1518CrossRef Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR et al (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. Bone Joint Surg Br 88:1513–1518CrossRef
14.
Zurück zum Zitat Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. doi: 10.1007/s00167-009-0879-9 Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. doi: 10.​1007/​s00167-009-0879-9
15.
Zurück zum Zitat Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD et al (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221CrossRefPubMed Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD et al (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221CrossRefPubMed
16.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed
17.
Zurück zum Zitat Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 7:1461–1466CrossRef Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 7:1461–1466CrossRef
18.
Zurück zum Zitat Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762CrossRefPubMed Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762CrossRefPubMed
19.
Zurück zum Zitat Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24:570–578CrossRefPubMed Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24:570–578CrossRefPubMed
20.
Zurück zum Zitat Madsen JL (2008) Bone SPECT/CT detection of a sequestrum in chronic-infected nonunion of the tibia. Clin Nucl Med 33:700–701CrossRefPubMed Madsen JL (2008) Bone SPECT/CT detection of a sequestrum in chronic-infected nonunion of the tibia. Clin Nucl Med 33:700–701CrossRefPubMed
21.
Zurück zum Zitat Mahmarian JJ (2007) Hybrid SPECT-CT: integration of CT coronary artery calcium scoring and angiography with myocardial perfusion. Curr Cardiol Rep 9:129–135CrossRefPubMed Mahmarian JJ (2007) Hybrid SPECT-CT: integration of CT coronary artery calcium scoring and angiography with myocardial perfusion. Curr Cardiol Rep 9:129–135CrossRefPubMed
22.
Zurück zum Zitat Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528CrossRefPubMed Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528CrossRefPubMed
23.
Zurück zum Zitat Roarke MC, Nguyen BD, Pockaj BA (2008) Applications of SPECT/CT in nuclear radiology. AJR Am J Roentgenol 191:W135–W150CrossRefPubMed Roarke MC, Nguyen BD, Pockaj BA (2008) Applications of SPECT/CT in nuclear radiology. AJR Am J Roentgenol 191:W135–W150CrossRefPubMed
24.
Zurück zum Zitat Romero J, Stahelin T, Wyss T, Hofmann S (2003) Significance of axial rotation alignment of components of knee prostheses. Orthopade 32:461–468PubMed Romero J, Stahelin T, Wyss T, Hofmann S (2003) Significance of axial rotation alignment of components of knee prostheses. Orthopade 32:461–468PubMed
25.
Zurück zum Zitat Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E et al (1996) Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res 325:181–189CrossRefPubMed Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E et al (1996) Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res 325:181–189CrossRefPubMed
26.
27.
Zurück zum Zitat Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed
28.
Zurück zum Zitat Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A (2008) Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 53:4595–4604CrossRefPubMed Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A (2008) Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 53:4595–4604CrossRefPubMed
29.
Zurück zum Zitat Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86:510–514PubMed Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86:510–514PubMed
30.
Zurück zum Zitat van der Ploeg IM, Valdes Olmos RA, Kroon BB, Nieweg OE (2008) The Hybrid SPECT/CT as an additional lymphatic mapping tool in patients with breast cancer. World J Surg 32:1930–1934CrossRefPubMed van der Ploeg IM, Valdes Olmos RA, Kroon BB, Nieweg OE (2008) The Hybrid SPECT/CT as an additional lymphatic mapping tool in patients with breast cancer. World J Surg 32:1930–1934CrossRefPubMed
31.
Zurück zum Zitat Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed
32.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365CrossRefPubMed Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365CrossRefPubMed
33.
Zurück zum Zitat Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRefPubMed Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRefPubMed
34.
Zurück zum Zitat Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20:661–668CrossRef Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20:661–668CrossRef
Metadaten
Titel
A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography
verfasst von
Michael T. Hirschmann
Farhad Iranpour
Praveen Konala
Anna Kerner
Helmut Rasch
Justin P. Cobb
Niklaus F. Friederich
Publikationsdatum
01.07.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 7/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1070-z

Weitere Artikel der Ausgabe 7/2010

Knee Surgery, Sports Traumatology, Arthroscopy 7/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.