Purpose

Historically, extramedullary techniques have focused on finding the femoral head center and referred mainly to the anterosuperior iliac spine (the FHC method) in total knee arthroplasty (TKA). The purpose of this study was to evaluate a new extramedullary alignment system that uses neutral overall limb mechanical alignment as an extramedullary reference (the MA method).

Methods

A retrospective review of 1018 TKAs (508 FHC group, 510 MA group) was performed to compare the radiographic results obtained using these two methods. There were 75 male patients and 577 female patients with varus osteoarthritis of the knee. Limb and prosthesis alignments in the coronal plane were investigated at 2 months after surgery.

Results

The accuracies of postoperative alignments of implanted prostheses were better in the MA group than in the FHC group, as assessed by (1) overall limb alignment (MA group, varus 1.4° ± 2.7°; FHC group, varus 2.2° ± 2.9°), and (2) femoral component coronal alignment (MA group, 89.4° ± 2.3°; FHC group, 88.0° ± 2.7°). Overall limb alignment was within 0° ± 5° of the mechanical axis in 96.1% of the MA group and in 86.6% of the FHC group. Mean femoral component medial angle was within 0° ± 5° in 98.4% of the MA group and in 92.5% of the FHC group.

Conclusion

The accuracies of the postoperative radiographic alignments of implanted prostheses were found to be improved when the mechanical axis of the overall lower limb was used as an extramedullary reference. This new reference system would help to achieve correct limb and prostheses alignments during TKA.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Aglietti P, Baldini A, Sensi L (2006) Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res 452:106–111PubMedCrossRef Aglietti P, Baldini A, Sensi L (2006) Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res 452:106–111PubMedCrossRef
2.
Zurück zum Zitat Baldini A, Adravanti P (2008) Less invasive TKA: extramedullary femoral reference without navigation. Clin Orthop Relat Res 466:2694–2700PubMedCrossRef Baldini A, Adravanti P (2008) Less invasive TKA: extramedullary femoral reference without navigation. Clin Orthop Relat Res 466:2694–2700PubMedCrossRef
3.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86:682–687CrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86:682–687CrossRef
4.
Zurück zum Zitat Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef
5.
Zurück zum Zitat Bonutti PM, Zywiel MG, Ulrich SD, Stroh DA, Seyler TM, Mont MA (2010) A comparison of subvastus and midvastus approaches in minimally invasive total knee arthroplasty. J Bone Jt Surg Am 92:575–582CrossRef Bonutti PM, Zywiel MG, Ulrich SD, Stroh DA, Seyler TM, Mont MA (2010) A comparison of subvastus and midvastus approaches in minimally invasive total knee arthroplasty. J Bone Jt Surg Am 92:575–582CrossRef
6.
Zurück zum Zitat Caillouette JT, Anzel SH (1990) Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res 251:198–199PubMed Caillouette JT, Anzel SH (1990) Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res 251:198–199PubMed
7.
Zurück zum Zitat Cates HE, Ritter MA, Keating EM, Faris PM (1993) Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res 286:32–39PubMed Cates HE, Ritter MA, Keating EM, Faris PM (1993) Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res 286:32–39PubMed
8.
Zurück zum Zitat Chang RN, Kim JH, Lee H, Baik HJ, Chung RK, Kim CH, Hwang TH (2010) Cerebral fat embolism after bilateral total knee replacement arthroplasty -A case report. Korean J Anesthesiol 59 Suppl:S207–S210PubMedCrossRef Chang RN, Kim JH, Lee H, Baik HJ, Chung RK, Kim CH, Hwang TH (2010) Cerebral fat embolism after bilateral total knee replacement arthroplasty -A case report. Korean J Anesthesiol 59 Suppl:S207–S210PubMedCrossRef
9.
Zurück zum Zitat Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86:372–377CrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86:372–377CrossRef
10.
Zurück zum Zitat Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569PubMedCrossRef Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569PubMedCrossRef
11.
Zurück zum Zitat Engh GA, Petersen TL (1990) Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty 5:1–8PubMedCrossRef Engh GA, Petersen TL (1990) Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty 5:1–8PubMedCrossRef
12.
Zurück zum Zitat Heyse TJ, Decking R, Davis J, Boettner F, Laskin RS (2009) Varus gonarthrosis predisposes to varus malalignment in TKA. HSS J 5:143–148PubMedCrossRef Heyse TJ, Decking R, Davis J, Boettner F, Laskin RS (2009) Varus gonarthrosis predisposes to varus malalignment in TKA. HSS J 5:143–148PubMedCrossRef
13.
Zurück zum Zitat Huang TW, Hsu WH, Peng KT, Hsu RW (2011) Total knee replacement in patients with significant femoral bowing in the coronal plane: a comparison of conventional and computer-assisted surgery in an Asian population. J Bone Jt Surg Br 93:345–350CrossRef Huang TW, Hsu WH, Peng KT, Hsu RW (2011) Total knee replacement in patients with significant femoral bowing in the coronal plane: a comparison of conventional and computer-assisted surgery in an Asian population. J Bone Jt Surg Br 93:345–350CrossRef
14.
Zurück zum Zitat Jenkins K, Chung F, Wennberg R, Etchells EE, Davey R (2002) Fat embolism syndrome and elective knee arthroplasty. Can J Anaesth 49:19–24PubMedCrossRef Jenkins K, Chung F, Wennberg R, Etchells EE, Davey R (2002) Fat embolism syndrome and elective knee arthroplasty. Can J Anaesth 49:19–24PubMedCrossRef
15.
Zurück zum Zitat Karachalios T, Giotikas D, Roidis N, Poultsides L, Bargiotas K, Malizos KN (2008) Total knee replacement performed with either a mini-midvastus or a standard approach: a prospective randomised clinical and radiological trial. J Bone Jt Surg Br 90:584–591CrossRef Karachalios T, Giotikas D, Roidis N, Poultsides L, Bargiotas K, Malizos KN (2008) Total knee replacement performed with either a mini-midvastus or a standard approach: a prospective randomised clinical and radiological trial. J Bone Jt Surg Br 90:584–591CrossRef
16.
Zurück zum Zitat Kim YH, Kim JS, Hong KS, Kim YJ, Kim JH (2008) Prevalence of fat embolism after total knee arthroplasty performed with or without computer navigation. J Bone Jt Surg Am 90:123–128CrossRef Kim YH, Kim JS, Hong KS, Kim YJ, Kim JH (2008) Prevalence of fat embolism after total knee arthroplasty performed with or without computer navigation. J Bone Jt Surg Am 90:123–128CrossRef
17.
Zurück zum Zitat Laskin R (1984) Alignment of total knee components. Orthopedics 7:62–65 Laskin R (1984) Alignment of total knee components. Orthopedics 7:62–65
18.
Zurück zum Zitat Laskin RS (2001) Intramedullary instrumentation: safer and more accurate than extramedullary instrumentation. Orthopedics 24:739PubMed Laskin RS (2001) Intramedullary instrumentation: safer and more accurate than extramedullary instrumentation. Orthopedics 24:739PubMed
19.
Zurück zum Zitat Lee DH, Seo JG, Moon YW (2008) Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty. Int Orthop 32:223–227PubMedCrossRef Lee DH, Seo JG, Moon YW (2008) Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty. Int Orthop 32:223–227PubMedCrossRef
20.
Zurück zum Zitat Lin WP, Lin J, Horng LC, Chang SM, Jiang CC (2009) Quadriceps-sparing, minimal-incision total knee arthroplasty: a comparative study. J Arthroplast 24:1024–1032CrossRef Lin WP, Lin J, Horng LC, Chang SM, Jiang CC (2009) Quadriceps-sparing, minimal-incision total knee arthroplasty: a comparative study. J Arthroplast 24:1024–1032CrossRef
21.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22:1097–1106CrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22:1097–1106CrossRef
22.
Zurück zum Zitat Morawa LG, Manley MT, Edidin AA, Reilly DT (1996) Transesophageal echocardiographic monitored events during total knee arthroplasty. Clin Orthop Relat Res 331:192–198PubMedCrossRef Morawa LG, Manley MT, Edidin AA, Reilly DT (1996) Transesophageal echocardiographic monitored events during total knee arthroplasty. Clin Orthop Relat Res 331:192–198PubMedCrossRef
23.
Zurück zum Zitat Mullaji A, Shetty GM, Kanna R, Sharma A (2010) Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults. Skeletal Radiol 39:363–368PubMedCrossRef Mullaji A, Shetty GM, Kanna R, Sharma A (2010) Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults. Skeletal Radiol 39:363–368PubMedCrossRef
24.
Zurück zum Zitat O’Connor MI, Brodersen MP, Feinglass NG, Leone BJ, Crook JE, Switzer BE (2010) Fat emboli in total knee arthroplasty: a prospective randomized study of computer-assisted navigation vs standard surgical technique. J Arthroplast 25:1034–1040CrossRef O’Connor MI, Brodersen MP, Feinglass NG, Leone BJ, Crook JE, Switzer BE (2010) Fat emboli in total knee arthroplasty: a prospective randomized study of computer-assisted navigation vs standard surgical technique. J Arthroplast 25:1034–1040CrossRef
25.
Zurück zum Zitat Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional versus navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106:941–948PubMed Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional versus navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106:941–948PubMed
26.
Zurück zum Zitat Pagnano MW, Meneghini RM, Trousdale RT (2006) Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res 452:102–105PubMedCrossRef Pagnano MW, Meneghini RM, Trousdale RT (2006) Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res 452:102–105PubMedCrossRef
27.
Zurück zum Zitat Papagelopoulos PJ, Apostolou CD, Karachalios TS, Themistocleous GS, Giannakopoulos CK, Ioannidis TT (2003) Pulmonary fat embolism after total hip and total knee arthroplasty. Orthopedics 26(523–527):528–529 Papagelopoulos PJ, Apostolou CD, Karachalios TS, Themistocleous GS, Giannakopoulos CK, Ioannidis TT (2003) Pulmonary fat embolism after total hip and total knee arthroplasty. Orthopedics 26(523–527):528–529
28.
Zurück zum Zitat Rajadhyaksha AD, Mehta H, Zelicof SB (2009) Use of tibialis anterior tendon as distal landmark for extramedullary tibial alignment in total knee arthroplasty: an anatomical study. Am J Orthop (Belle Mead NJ) 38:E68–E70 Rajadhyaksha AD, Mehta H, Zelicof SB (2009) Use of tibialis anterior tendon as distal landmark for extramedullary tibial alignment in total knee arthroplasty: an anatomical study. Am J Orthop (Belle Mead NJ) 38:E68–E70
29.
Zurück zum Zitat RBaJ Rand (1985) Alignment and design in unicompartmental knee arthroplasty. In: Dorr LD (ed) The knee papers of t he first scientific meeting of the knee society. University Park Press, Baltimore, pp 121–136 RBaJ Rand (1985) Alignment and design in unicompartmental knee arthroplasty. In: Dorr LD (ed) The knee papers of t he first scientific meeting of the knee society. University Park Press, Baltimore, pp 121–136
30.
Zurück zum Zitat Restrepo C, Hozack WJ, Orozco F, Parvizi J (2008) Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation. Comput Aided Surg 13:167–172PubMed Restrepo C, Hozack WJ, Orozco F, Parvizi J (2008) Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation. Comput Aided Surg 13:167–172PubMed
31.
Zurück zum Zitat Ritter MA, Campbell ED (1988) A model for easy location of the center of the femoral head during total knee arthroplasty. J Arthroplast 3 Suppl:S59–S61CrossRef Ritter MA, Campbell ED (1988) A model for easy location of the center of the femoral head during total knee arthroplasty. J Arthroplast 3 Suppl:S59–S61CrossRef
32.
Zurück zum Zitat Ritter MA, Faris GW, Faris PM, Davis KE (2004) Total knee arthroplasty in patients with angular varus or valgus deformities of > or = 20 degrees. J Arthroplasty 19:862–866PubMedCrossRef Ritter MA, Faris GW, Faris PM, Davis KE (2004) Total knee arthroplasty in patients with angular varus or valgus deformities of > or = 20 degrees. J Arthroplasty 19:862–866PubMedCrossRef
33.
Zurück zum Zitat Sawant MR, Murty A, Ireland J (2004) A clinical method for locating the femoral head centre during total knee arthroplasty. Knee 11:209–212PubMedCrossRef Sawant MR, Murty A, Ireland J (2004) A clinical method for locating the femoral head centre during total knee arthroplasty. Knee 11:209–212PubMedCrossRef
34.
Zurück zum Zitat Schneider M, Heisel C, Aldinger PR, Breusch SJ (2007) Use of palpable tendons for extramedullary tibial alignment in total knee arthroplasty. J Arthroplast 22:219–226CrossRef Schneider M, Heisel C, Aldinger PR, Breusch SJ (2007) Use of palpable tendons for extramedullary tibial alignment in total knee arthroplasty. J Arthroplast 22:219–226CrossRef
35.
Zurück zum Zitat Seo JG, Kim BK, Moon YW, Kim JH, Yoon BH, Ahn TK, Lee DH (2009) Bony landmarks for determining the mechanical axis of the femur in the sagittal plane during total knee arthroplasty. Clin Orthop Surg 1:128–131PubMedCrossRef Seo JG, Kim BK, Moon YW, Kim JH, Yoon BH, Ahn TK, Lee DH (2009) Bony landmarks for determining the mechanical axis of the femur in the sagittal plane during total knee arthroplasty. Clin Orthop Surg 1:128–131PubMedCrossRef
36.
Zurück zum Zitat Seo JG, Lim JS, Lee HI, Woo KJ (2010) An extramedullary femoral alignment system in total knee arthroplasty using the inter-femoral head center distance. J Korean Orthop Assoc 45:347–355CrossRef Seo JG, Lim JS, Lee HI, Woo KJ (2010) An extramedullary femoral alignment system in total knee arthroplasty using the inter-femoral head center distance. J Korean Orthop Assoc 45:347–355CrossRef
37.
Zurück zum Zitat Seo JG, Moon YW, Lim JS, Park SJ, Kim SM (2011) Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis. Knee Surg Sports Traumatol Arthrosc doi:10.1007/s00167-011-1597-7 Seo JG, Moon YW, Lim JS, Park SJ, Kim SM (2011) Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis. Knee Surg Sports Traumatol Arthrosc doi:10.​1007/​s00167-011-1597-7
38.
Zurück zum Zitat Sulek CA, Davies LK, Enneking FK, Gearen PA, Lobato EB (1999) Cerebral microembolism diagnosed by transcranial Doppler during total knee arthroplasty: correlation with transesophageal echocardiography. Anesthesiology 91:672–676PubMedCrossRef Sulek CA, Davies LK, Enneking FK, Gearen PA, Lobato EB (1999) Cerebral microembolism diagnosed by transcranial Doppler during total knee arthroplasty: correlation with transesophageal echocardiography. Anesthesiology 91:672–676PubMedCrossRef
39.
Zurück zum Zitat Tillett ED, Engh GA, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res 230:176–181PubMed Tillett ED, Engh GA, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res 230:176–181PubMed
40.
Zurück zum Zitat Tingart M, Luring C, Bathis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef Tingart M, Luring C, Bathis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef
41.
Zurück zum Zitat der Zwaag HM, Valstar ER, van der Molen AJ, Nelissen RG (2008) Transepicondylar axis accuracy in computer assisted knee surgery: a comparison of the CT-based measured axis versus the CAS-determined axis. Comput Aided Surg 13:200–206CrossRef der Zwaag HM, Valstar ER, van der Molen AJ, Nelissen RG (2008) Transepicondylar axis accuracy in computer assisted knee surgery: a comparison of the CT-based measured axis versus the CAS-determined axis. Comput Aided Surg 13:200–206CrossRef
42.
Zurück zum Zitat Vince KG (1987) Fat embolism and total knee arthroplasty. Can J Surg 30:227PubMed Vince KG (1987) Fat embolism and total knee arthroplasty. Can J Surg 30:227PubMed
43.
Zurück zum Zitat Weiss SJ, Cheung AT, Stecker MM, Garino JP, Hughes JE, Murphy FL (1996) Fatal paradoxical cerebral embolization during bilateral knee arthroplasty. Anesthesiology 84:721–723PubMedCrossRef Weiss SJ, Cheung AT, Stecker MM, Garino JP, Hughes JE, Murphy FL (1996) Fatal paradoxical cerebral embolization during bilateral knee arthroplasty. Anesthesiology 84:721–723PubMedCrossRef
44.
Zurück zum Zitat Yau WP, Chiu KY, Tang WM, Ng TP (2007) Coronal bowing of the femur and tibia in Chinese: its incidence and effects on total knee arthroplasty planning. J Orthop Surg (Hong Kong) 15:32–36 Yau WP, Chiu KY, Tang WM, Ng TP (2007) Coronal bowing of the femur and tibia in Chinese: its incidence and effects on total knee arthroplasty planning. J Orthop Surg (Hong Kong) 15:32–36
45.
Zurück zum Zitat Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466:935–945PubMedCrossRef Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466:935–945PubMedCrossRef
46.
Zurück zum Zitat Zimmerman RL, Kroner LF 3rd, Blomberg DJ, Nollet DJ (1983) Fatal fat embolism following total knee arthroplasty. Minn Med 66:213–216PubMed Zimmerman RL, Kroner LF 3rd, Blomberg DJ, Nollet DJ (1983) Fatal fat embolism following total knee arthroplasty. Minn Med 66:213–216PubMed
Metadaten
Titel
An alternative method to create extramedullary references in total knee arthroplasty
verfasst von
Jai-Gon Seo
Young-Wan Moon
Sang-Hoon Park
Jae-Woo Shim
Sang-Min Kim
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 7/2012
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1668-9

Weitere Artikel der Ausgabe 7/2012

Knee Surgery, Sports Traumatology, Arthroscopy 7/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.