Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2013

01.10.2013 | Knee

Rotational limb alignment changes following total knee arthroplasty

verfasst von: Oliver Hauschild, Matthias Muenzberg, Dagmar Knothe, Lukas Konstantinidis, Peter Helwig, Norbert P. Sudkamp, Friedrich W. Thielemann

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 10/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of the present study was to assess the changes in rotational alignment introduced by total knee arthroplasty (TKA) and the reproducibility of pre- and postoperative CT measurements of rotational limb alignment.

Methods

For this purpose we analyzed data from 196 consecutive cruciate-retaining, fixed bearing Columbus TKA procedures. Both pre- and postoperative scans torsion difference CT scans were available for measurements in 89 cases. Using these CT scans the neck-malleolar angle (NMA), the femoral posterior condylar angle (fPCA), the tibial posterior condylar axis (tPCA) and the tibial torsion angle (TTA) were independently assessed by three raters. CT scans were re-evaluated 8 weeks later by the most experienced rater for assessment of intraobserver agreement.

Results

Measurements of all angles were prone to high standard deviations reflecting interindividual variability. Mean fPCA changed from 1.3° to 2.7° internal rotation preoperatively to 0.1°–1.9° internal rotation postoperatively. Based on a relative external rotation of the tibial base plate as compared to the preoperative situation, we found a relative internal rotation of the postoperative NMA and tibial torsion of 3°–5.4° and 6°–7.5°, respectively. Intra- and interobserver agreement was strong for all angles assessed (ICCs 0.7–1.0) except for fPCA (ICC 0.2–0.6). However, mean absolute measurement differences for fPCA were clinically acceptable (1.2°–2.6°).

Conclusions

Reproducibility of CT rotational limb alignment measurements was found to be clinically acceptable. Rotational alignment of the femoral and even more so of the tibial component will ultimately affect the rotational alignment of the entire limb—at least when fixed bearings are used.

Level of evidence

Diagnostic study, Level III.
Literatur
1.
Zurück zum Zitat Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163PubMedCrossRef Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163PubMedCrossRef
2.
Zurück zum Zitat Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176PubMedCrossRef Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176PubMedCrossRef
3.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153PubMedCrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153PubMedCrossRef
4.
Zurück zum Zitat Berger RA, Rubash HE (2001) Rotational instability and malrotation after total knee arthroplasty. Orthop Clin N Am 32(4):639–647CrossRef Berger RA, Rubash HE (2001) Rotational instability and malrotation after total knee arthroplasty. Orthop Clin N Am 32(4):639–647CrossRef
5.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed
6.
Zurück zum Zitat Bonnin MP, Saffarini M, Mercier PE, Laurent JR, Carrillon Y (2011) Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty? J Arthroplasty 26(2):260–267;e261–e262 Bonnin MP, Saffarini M, Mercier PE, Laurent JR, Carrillon Y (2011) Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty? J Arthroplasty 26(2):260–267;e261–e262
7.
Zurück zum Zitat Galaud B, Beaufils P, Michaut M, Abadie P, Fallet L, Boisrenoult P (2008) Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases. Rev Chir Orthop Reparatrice Appar Mot 94(6):573–579PubMedCrossRef Galaud B, Beaufils P, Michaut M, Abadie P, Fallet L, Boisrenoult P (2008) Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases. Rev Chir Orthop Reparatrice Appar Mot 94(6):573–579PubMedCrossRef
8.
Zurück zum Zitat Grafinger RW, Datz L, Hitzl W, Dorn U (2008) CT scans increase rotational accuracy in total knee arthroplasty. Z Orthop Unfall 146(6):782–787PubMedCrossRef Grafinger RW, Datz L, Hitzl W, Dorn U (2008) CT scans increase rotational accuracy in total knee arthroplasty. Z Orthop Unfall 146(6):782–787PubMedCrossRef
9.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13(7):812–815PubMedCrossRef Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13(7):812–815PubMedCrossRef
10.
Zurück zum Zitat Griffin FM, Math K, Scuderi GR, Insall JN, Poilvache PL (2000) Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees. J Arthroplasty 15(3):354–359PubMedCrossRef Griffin FM, Math K, Scuderi GR, Insall JN, Poilvache PL (2000) Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees. J Arthroplasty 15(3):354–359PubMedCrossRef
11.
Zurück zum Zitat Heesterbeek PJ, Jacobs WC, Wymenga AB (2009) Effects of the balanced gap technique on femoral component rotation in TKA. Clin Orthop Relat Res 467:1015–1022PubMedCrossRef Heesterbeek PJ, Jacobs WC, Wymenga AB (2009) Effects of the balanced gap technique on femoral component rotation in TKA. Clin Orthop Relat Res 467:1015–1022PubMedCrossRef
12.
Zurück zum Zitat Heesterbeek PJ, Wymenga AB (2010) Correction of axial and rotational alignment after medial and lateral releases during balanced gap TKA. A clinical study of 54 patients. Acta Orthop 81(3):347–353PubMedCrossRef Heesterbeek PJ, Wymenga AB (2010) Correction of axial and rotational alignment after medial and lateral releases during balanced gap TKA. A clinical study of 54 patients. Acta Orthop 81(3):347–353PubMedCrossRef
13.
Zurück zum Zitat Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS (1981) CT determination of femoral torsion. AJR Am J Roentgenol 137(1):97–101PubMedCrossRef Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS (1981) CT determination of femoral torsion. AJR Am J Roentgenol 137(1):97–101PubMedCrossRef
15.
Zurück zum Zitat Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18(7):939–944PubMedCrossRef Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18(7):939–944PubMedCrossRef
16.
Zurück zum Zitat Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36PubMedCrossRef Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36PubMedCrossRef
17.
Zurück zum Zitat Hofmann S, Seitlinger G, Djahani O, Pietsch M (2011) The painful knee after TKA: a diagnostic algorithm for failure analysis. Knee Surg Sports Traumatol Arthrosc 19(9):1442–1452PubMedCrossRef Hofmann S, Seitlinger G, Djahani O, Pietsch M (2011) The painful knee after TKA: a diagnostic algorithm for failure analysis. Knee Surg Sports Traumatol Arthrosc 19(9):1442–1452PubMedCrossRef
18.
Zurück zum Zitat Liodakis E, Aljuneidi W, Krettek C, Ettinger M, Kenawey M (2011) The neck-malleolar angle: an alternative method for measuring total lower limb torsion that considers the knee joint rotation angle. Skeletal Radiol 40(5):617–621PubMedCrossRef Liodakis E, Aljuneidi W, Krettek C, Ettinger M, Kenawey M (2011) The neck-malleolar angle: an alternative method for measuring total lower limb torsion that considers the knee joint rotation angle. Skeletal Radiol 40(5):617–621PubMedCrossRef
19.
Zurück zum Zitat Liodakis E, Doxastaki I, Chu K, Krettek C, Gaulke R, Citak M, Kenawey M (2012) Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques. Skeletal Radiol 41(3):305–311PubMedCrossRef Liodakis E, Doxastaki I, Chu K, Krettek C, Gaulke R, Citak M, Kenawey M (2012) Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques. Skeletal Radiol 41(3):305–311PubMedCrossRef
20.
Zurück zum Zitat Lutzner J, Krummenauer F, Gunther KP, Kirschner S (2010) Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 11:57PubMedCrossRef Lutzner J, Krummenauer F, Gunther KP, Kirschner S (2010) Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 11:57PubMedCrossRef
21.
Zurück zum Zitat Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14(3):152–156PubMed Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14(3):152–156PubMed
22.
Zurück zum Zitat Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br 92(9):1238–1244PubMed Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br 92(9):1238–1244PubMed
23.
Zurück zum Zitat Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional vs. navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106(11):941–948PubMed Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional vs. navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106(11):941–948PubMed
24.
Zurück zum Zitat Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20(6):1057–1063PubMedCrossRef Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20(6):1057–1063PubMedCrossRef
25.
Zurück zum Zitat Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef
27.
Zurück zum Zitat van der Linden-van der Zwaag HM, Bos J, van der Heide HJ, Nelissen RG (2011) A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery. Int Orthop 35(6):845–850PubMedCrossRef van der Linden-van der Zwaag HM, Bos J, van der Heide HJ, Nelissen RG (2011) A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery. Int Orthop 35(6):845–850PubMedCrossRef
28.
Zurück zum Zitat Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372PubMedCrossRef Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372PubMedCrossRef
29.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16(5):358–365PubMedCrossRef Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16(5):358–365PubMedCrossRef
30.
Zurück zum Zitat Waidelich HA, Strecker W, Schneider E (1992) Computed tomographic torsion-angle and length measurement of the lower extremity. The methods, normal values and radiation load. Rofo 157(3):245–251PubMedCrossRef Waidelich HA, Strecker W, Schneider E (1992) Computed tomographic torsion-angle and length measurement of the lower extremity. The methods, normal values and radiation load. Rofo 157(3):245–251PubMedCrossRef
31.
Zurück zum Zitat Weir JP (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 19(1):231–240PubMed Weir JP (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 19(1):231–240PubMed
32.
Zurück zum Zitat Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16(4):493–497PubMedCrossRef Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16(4):493–497PubMedCrossRef
33.
Zurück zum Zitat Yoshino N, Takai S, Watanabe Y, Fujiwara H, Ohshima Y, Hirasawa Y (2001) Primary total knee arthroplasty for supracondylar/condylar femoral fracture in osteoarthritic knees. J Arthroplasty 16(4):471–475PubMedCrossRef Yoshino N, Takai S, Watanabe Y, Fujiwara H, Ohshima Y, Hirasawa Y (2001) Primary total knee arthroplasty for supracondylar/condylar femoral fracture in osteoarthritic knees. J Arthroplasty 16(4):471–475PubMedCrossRef
Metadaten
Titel
Rotational limb alignment changes following total knee arthroplasty
verfasst von
Oliver Hauschild
Matthias Muenzberg
Dagmar Knothe
Lukas Konstantinidis
Peter Helwig
Norbert P. Sudkamp
Friedrich W. Thielemann
Publikationsdatum
01.10.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2322-x

Weitere Artikel der Ausgabe 10/2013

Knee Surgery, Sports Traumatology, Arthroscopy 10/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.