Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2016

22.01.2016 | Knee

Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement

verfasst von: S. Schröter, C. Ihle, D. W. Elson, S. Döbele, U. Stöckle, A. Ateschrang

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Medial opening wedge high tibial osteotomy (MOW HTO) is now a successful operation with a range of indications, requiring an individualised approach to the choice of intended correction. This manuscript introduces the concept of surgical accuracy as the absolute deviation of the achieved correction from the intended correction, where small values represent greater accuracy. Surgical accuracy is compared in a randomised controlled trial (RCT) between gap measurement and computer navigation groups.

Methods

This was a prospective RCT conducted over 3 years of 120 consecutive patients with varus malalignment and medial compartment osteoarthritis, who underwent MOW HTO. All procedures were planned with digital software. Patients were randomly assigned into gap measurement or computer navigation groups. Coronal plane alignment was judged using the mechanical tibiofemoral angle (mTFA), before and after surgery. Absolute (positive) values were calculated for surgical accuracy in each individual case.

Results

There was no significant difference in the mean intended correction between groups. The achieved mTFA revealed a small under-correction in both groups. This was attributed to a failure to account for saw blade thickness (gap measurement) and over-compensation for weight bearing (computer navigation). Surgical accuracy was 1.7° ± 1.2° (gap measurement) compared to 2.1° ± 1.4° (computer navigation) without statistical significance. The difference in tibial slope increases of 2.7° ± 3.9° (gap measurement) and 2.1° ± 3.9° (computer navigation) had statistical significance (P < 0.001) but magnitude (0.6°) without clinical relevance.

Conclusion

Surgical accuracy as described here is a new way to judge achieved alignment following knee osteotomy for individual cases. This work is clinically relevant because coronal surgical accuracy was not superior in either group. Therefore, the increased expense and surgical time associated with navigated MOW HTO is not supported, because meticulously conducted gap measurement yields equivalent surgical accuracy.

Level of evidence

I.
Literatur
1.
Zurück zum Zitat Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14(3):291–300CrossRefPubMed Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14(3):291–300CrossRefPubMed
2.
Zurück zum Zitat Agneskirchner JD, Hurschler C, Wrann CD, Lobenhoffer P (2007) The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: a biomechanical study. Arthroscopy 23(8):852–861CrossRefPubMed Agneskirchner JD, Hurschler C, Wrann CD, Lobenhoffer P (2007) The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: a biomechanical study. Arthroscopy 23(8):852–861CrossRefPubMed
3.
Zurück zum Zitat Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20(3):586–593CrossRefPubMed Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20(3):586–593CrossRefPubMed
4.
Zurück zum Zitat Amendola A, Rorabeck CH, Bourne RB, Apyan PM (1989) Total knee arthroplasty following high tibial osteotomy for osteoarthritis. J Arthroplasty 4(Suppl):S11–S17CrossRefPubMed Amendola A, Rorabeck CH, Bourne RB, Apyan PM (1989) Total knee arthroplasty following high tibial osteotomy for osteoarthritis. J Arthroplasty 4(Suppl):S11–S17CrossRefPubMed
5.
Zurück zum Zitat Baier C, Maderbacher G, Springorum HR, Zeman F, Fitz W, Schaumburger J, Grifka J, Beckmann J (2014) No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(8):1819–1826CrossRefPubMed Baier C, Maderbacher G, Springorum HR, Zeman F, Fitz W, Schaumburger J, Grifka J, Beckmann J (2014) No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(8):1819–1826CrossRefPubMed
6.
Zurück zum Zitat Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RMD, Reijman M, Pols HAP, Bierma-Zeinstra SMA (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56(4):1204–1211CrossRefPubMed Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RMD, Reijman M, Pols HAP, Bierma-Zeinstra SMA (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56(4):1204–1211CrossRefPubMed
7.
Zurück zum Zitat Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264 Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264
8.
Zurück zum Zitat El-Azab H, Glabgly P, Paul J, Imhoff AB, Hinterwimmer S (2010) Patellar height and posterior tibial slope after open- and closed-wedge high tibial osteotomy: a radiological study on 100 patients. Am J Sports Med 38(2):323–329CrossRefPubMed El-Azab H, Glabgly P, Paul J, Imhoff AB, Hinterwimmer S (2010) Patellar height and posterior tibial slope after open- and closed-wedge high tibial osteotomy: a radiological study on 100 patients. Am J Sports Med 38(2):323–329CrossRefPubMed
9.
Zurück zum Zitat Elson DW, Dawson M, Wilson C, Risebury M, Wilson A (2015) The UK Knee Osteotomy Registry (UKKOR). Knee 22(1):1–3CrossRefPubMed Elson DW, Dawson M, Wilson C, Risebury M, Wilson A (2015) The UK Knee Osteotomy Registry (UKKOR). Knee 22(1):1–3CrossRefPubMed
10.
Zurück zum Zitat Elson DW, Mahoney M, Eyre-Brooke AI, Yasen SK, Sabnis BM, Cox G, Rossiter ND, Risebury MJ, Wilson AJ (2015) Correction accuracy in medial opening wedge high tibial ostoetomy, using PreOPlan software. Eposter in 10th biennial ISAKOS congress, Lyon, France Elson DW, Mahoney M, Eyre-Brooke AI, Yasen SK, Sabnis BM, Cox G, Rossiter ND, Risebury MJ, Wilson AJ (2015) Correction accuracy in medial opening wedge high tibial ostoetomy, using PreOPlan software. Eposter in 10th biennial ISAKOS congress, Lyon, France
11.
Zurück zum Zitat Elson DW, Petheram TG, Dawson MJ (2015) High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci’s method. Knee Surg Sports Traumatol Arthrosc 23(7):2041–2048CrossRefPubMed Elson DW, Petheram TG, Dawson MJ (2015) High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci’s method. Knee Surg Sports Traumatol Arthrosc 23(7):2041–2048CrossRefPubMed
12.
Zurück zum Zitat Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, Giannini S (2014) Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc 22(3):621–629CrossRefPubMed Ensini A, Timoncini A, Cenni F, Belvedere C, Fusai F, Leardini A, Giannini S (2014) Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc 22(3):621–629CrossRefPubMed
13.
Zurück zum Zitat Feucht MJ, Minzlaff P, Saier T, Cotic M, Südkamp NP, Niemeyer P, Imhoff AB, Hinterwimmer S (2014) Degree of axis correction in valgus high tibial osteotomy: proposal of an individualised approach. Int Orthop 38(11):2273–2280CrossRefPubMed Feucht MJ, Minzlaff P, Saier T, Cotic M, Südkamp NP, Niemeyer P, Imhoff AB, Hinterwimmer S (2014) Degree of axis correction in valgus high tibial osteotomy: proposal of an individualised approach. Int Orthop 38(11):2273–2280CrossRefPubMed
14.
Zurück zum Zitat Gebhard F, Krettek C, Hüfner T, Grützner PA, Stöckle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P, AO CSEG (2011) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131(3):297–302CrossRefPubMed Gebhard F, Krettek C, Hüfner T, Grützner PA, Stöckle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P, AO CSEG (2011) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131(3):297–302CrossRefPubMed
15.
Zurück zum Zitat Hauschild O, Konstantinidis L, Strohm PC, Niemeyer P, Suedkamp NP, Helwig P (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg Sports Traumatol Arthrosc 17(10):1143–1151CrossRefPubMed Hauschild O, Konstantinidis L, Strohm PC, Niemeyer P, Suedkamp NP, Helwig P (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg Sports Traumatol Arthrosc 17(10):1143–1151CrossRefPubMed
16.
Zurück zum Zitat Heijens E, Kornherr P, Meister C (2009) The role of navigation in high tibial osteotomy: a study of 50 patients. Orthopedics 32(10 Suppl):40–43CrossRefPubMed Heijens E, Kornherr P, Meister C (2009) The role of navigation in high tibial osteotomy: a study of 50 patients. Orthopedics 32(10 Suppl):40–43CrossRefPubMed
17.
Zurück zum Zitat Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354CrossRefPubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354CrossRefPubMed
18.
Zurück zum Zitat Hinterwimmer S, Beitzel K, Paul J, Kirchhoff C, Sauerschnig M, von Eisenhart-Rothe R, Imhoff AB (2011) Control of posterior tibial slope and patellar height in open-wedge valgus high tibial osteotomy. Am J Sports Med 39(4):851–856CrossRefPubMed Hinterwimmer S, Beitzel K, Paul J, Kirchhoff C, Sauerschnig M, von Eisenhart-Rothe R, Imhoff AB (2011) Control of posterior tibial slope and patellar height in open-wedge valgus high tibial osteotomy. Am J Sports Med 39(4):851–856CrossRefPubMed
19.
Zurück zum Zitat Iorio R, Bolle G, Conteduca F, Valeo L, Conteduca J, Mazza D, Ferretti A (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21(10):2296–2300CrossRefPubMed Iorio R, Bolle G, Conteduca F, Valeo L, Conteduca J, Mazza D, Ferretti A (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21(10):2296–2300CrossRefPubMed
20.
Zurück zum Zitat Iorio R, Pagnottelli M, Vadalà A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21(1):113–119CrossRefPubMed Iorio R, Pagnottelli M, Vadalà A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21(1):113–119CrossRefPubMed
21.
Zurück zum Zitat Jenny J-Y, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9(4):161–165CrossRefPubMed Jenny J-Y, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9(4):161–165CrossRefPubMed
22.
Zurück zum Zitat Jenny J-Y, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system. J Arthroplasty 20(7):832–839CrossRefPubMed Jenny J-Y, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system. J Arthroplasty 20(7):832–839CrossRefPubMed
24.
Zurück zum Zitat Kim S-J, Koh Y-G, Chun Y-M, Kim Y-C, Park Y-S, Sung C-H (2009) Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: a 1-year retrospective, comparative study. Knee Surg Sports Traumatol Arthrosc 17(2):128–134CrossRefPubMed Kim S-J, Koh Y-G, Chun Y-M, Kim Y-C, Park Y-S, Sung C-H (2009) Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: a 1-year retrospective, comparative study. Knee Surg Sports Traumatol Arthrosc 17(2):128–134CrossRefPubMed
25.
Zurück zum Zitat Kyung BS, Kim JG, Jang K-M, Chang M, Moon Y-W, Ahn JH, Wang JH (2013) Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs. Am J Sports Med 41(10):2368–2374CrossRefPubMed Kyung BS, Kim JG, Jang K-M, Chang M, Moon Y-W, Ahn JH, Wang JH (2013) Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs. Am J Sports Med 41(10):2368–2374CrossRefPubMed
26.
Zurück zum Zitat Lee YS, Kim MG, Byun HW, Kim SB, Kim JG (2015) Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 23(3):846–851CrossRefPubMed Lee YS, Kim MG, Byun HW, Kim SB, Kim JG (2015) Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 23(3):846–851CrossRefPubMed
27.
Zurück zum Zitat Lo WN, Cheung KW, Yung SH, Chiu KH (2009) Arthroscopy-assisted computer navigation in high tibial osteotomy for varus knee deformity. J Orthop Surg (Hong Kong) 17(1):51–55CrossRef Lo WN, Cheung KW, Yung SH, Chiu KH (2009) Arthroscopy-assisted computer navigation in high tibial osteotomy for varus knee deformity. J Orthop Surg (Hong Kong) 17(1):51–55CrossRef
28.
Zurück zum Zitat Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138CrossRefPubMed Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138CrossRefPubMed
29.
Zurück zum Zitat Marti CB, Gautier E, Wachtl SW, Jakob RP (2004) Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 20(4):366–372CrossRefPubMed Marti CB, Gautier E, Wachtl SW, Jakob RP (2004) Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 20(4):366–372CrossRefPubMed
30.
Zurück zum Zitat Müller M, Strecker W (2008) Arthroscopy prior to osteotomy around the knee? Arch Orthop Trauma Surg 128(11):1217–1221CrossRefPubMed Müller M, Strecker W (2008) Arthroscopy prior to osteotomy around the knee? Arch Orthop Trauma Surg 128(11):1217–1221CrossRefPubMed
31.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107CrossRefPubMed Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107CrossRefPubMed
32.
Zurück zum Zitat Ollivier M, Tribot-Laspiere Q, Amzallag J, Boisrenoult P, Pujol N, Beaufils P (2015) Abnormal rate of intraoperative and postoperative implant positioning outliers using “MRI-based patient-specific” compared to “computer assisted” instrumentation in total knee replacement. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3645-1 PubMed Ollivier M, Tribot-Laspiere Q, Amzallag J, Boisrenoult P, Pujol N, Beaufils P (2015) Abnormal rate of intraoperative and postoperative implant positioning outliers using “MRI-based patient-specific” compared to “computer assisted” instrumentation in total knee replacement. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3645-1 PubMed
33.
Zurück zum Zitat Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25(3):425–465PubMed Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25(3):425–465PubMed
34.
Zurück zum Zitat Reising K, Strohm PC, Hauschild O, Schmal H, Khattab M, Südkamp NP, Niemeyer P (2013) Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique. Knee Surg Sports Traumatol Arthrosc 21(1):181–188CrossRefPubMed Reising K, Strohm PC, Hauschild O, Schmal H, Khattab M, Südkamp NP, Niemeyer P (2013) Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique. Knee Surg Sports Traumatol Arthrosc 21(1):181–188CrossRefPubMed
35.
Zurück zum Zitat Ribeiro CH, Severino NR, de Barros Moraes, Fucs PM (2014) Opening wedge high tibial osteotomy: navigation system compared to the conventional technique in a controlled clinical study. Int Orthop 38(8):1627–1631CrossRefPubMedPubMedCentral Ribeiro CH, Severino NR, de Barros Moraes, Fucs PM (2014) Opening wedge high tibial osteotomy: navigation system compared to the conventional technique in a controlled clinical study. Int Orthop 38(8):1627–1631CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Schröter S, Günzel J, Freude T, Ateschrang A, Stöckle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unf 150(4):368–373CrossRef Schröter S, Günzel J, Freude T, Ateschrang A, Stöckle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unf 150(4):368–373CrossRef
37.
Zurück zum Zitat Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21(1):189–196CrossRefPubMed Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21(1):189–196CrossRefPubMed
38.
Zurück zum Zitat Sharma L, Song J, Dunlop D, Felson D, Lewis CE, Segal N, Torner J, Cooke TDV, Hietpas J, Lynch J, Nevitt M (2010) Varus and valgus alignment and incident and progressive knee osteoarthritis. Ann Rheum Dis 69(11):1940–1945CrossRefPubMedPubMedCentral Sharma L, Song J, Dunlop D, Felson D, Lewis CE, Segal N, Torner J, Cooke TDV, Hietpas J, Lynch J, Nevitt M (2010) Varus and valgus alignment and incident and progressive knee osteoarthritis. Ann Rheum Dis 69(11):1940–1945CrossRefPubMedPubMedCentral
39.
Zurück zum Zitat Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21(1):3–22CrossRefPubMed Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21(1):3–22CrossRefPubMed
40.
Zurück zum Zitat Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia—early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia—early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed
41.
Zurück zum Zitat Tanamas S, Hanna FS, Cicuttini FM, Wluka AE, Berry P, Urquhart DM (2009) Does knee malalignment increase the risk of development and progression of knee osteoarthritis? A systematic review. Arthritis Rheum 61(4):459–467CrossRefPubMed Tanamas S, Hanna FS, Cicuttini FM, Wluka AE, Berry P, Urquhart DM (2009) Does knee malalignment increase the risk of development and progression of knee osteoarthritis? A systematic review. Arthritis Rheum 61(4):459–467CrossRefPubMed
42.
Zurück zum Zitat Vint H, Elson DW, Phelan SM, Middleton P, Dawson MJ (2015) Correction accuracy in medial opening wedge high tibial osteotomy using the Miniaci method. Eposter in 10th biennial ISAKOS congress, Lyon, France Vint H, Elson DW, Phelan SM, Middleton P, Dawson MJ (2015) Correction accuracy in medial opening wedge high tibial osteotomy using the Miniaci method. Eposter in 10th biennial ISAKOS congress, Lyon, France
Metadaten
Titel
Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement
verfasst von
S. Schröter
C. Ihle
D. W. Elson
S. Döbele
U. Stöckle
A. Ateschrang
Publikationsdatum
22.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-3983-7

Weitere Artikel der Ausgabe 11/2016

Knee Surgery, Sports Traumatology, Arthroscopy 11/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie