Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2017

25.05.2016 | Knee

Superior femoral component alignment can be achieved with Oxford microplasty instrumentation after minimally invasive unicompartmental knee arthroplasty

verfasst von: Yihui Tu, Huaming Xue, Tong Ma, Tao Wen, Tao Yang, Hui Zhang, Minwei Cai

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Oxford microplasty (MP) instrumentation has been developed to facilitate the reproducible and consistent performance of minimally invasive unicompartmental knee arthroplasty (MI-UKA) operation. The aim of this study was to compare the clinical and radiographic results of two groups of patients implanted using either a conventional instrumentation technique or an MP technique.

Methods

A prospective cohort study of 108 knees in 108 patients who underwent an MI-UKA procedure using either conventionally instrumented UKA (CI-UKA) (52 knees of 52 patients) or MP-assisted UKA (MP-UKA) (56 knees of 56 patients). The clinical assessment included the Oxford Knee Score (OKS), the Knee Society Score (KSS), a visual analogue scale (VAS) for pain, and range of motion (ROM). Complications were also recorded.

Results

No significant differences were observed between the two groups regarding OKS, KSS, VAS, and ROM. There were also no significant differences in terms of mechanical limb alignment and tibia implant alignment. However, the MP-UKA group showed significantly more accurate positioning of the femoral component than the CI-UKA group. Additionally, the MP-UKA group had more femoral prostheses implanted in the “satisfactory” range and fewer “outliers” than the CI-UKA group. No significant difference in complications was noted between the two groups.

Conclusion

This study suggested that compared with CI-UKA, MP-UKA provides significant improvements in increasing the accuracy of sagittal and coronal implantation of the femoral component and in reducing the numbers of outliers for femoral prosthetic alignment. It is advocated that the MP system should be considered when MI-UKA is performed.

Level of evidence

Therapeutic study, Level IV.
Literatur
1.
Zurück zum Zitat Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Jt Surg Br 80-B:63–69CrossRef Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Jt Surg Br 80-B:63–69CrossRef
2.
Zurück zum Zitat Emerson RH Jr, Hansborough T, Reitman RD, Rosenfeldt W, Higgins LL (2002) Comparison of a mobile with a fixed-bearing unicompartmental knee implant. Clin Orthop Relat Res 404:62–70CrossRef Emerson RH Jr, Hansborough T, Reitman RD, Rosenfeldt W, Higgins LL (2002) Comparison of a mobile with a fixed-bearing unicompartmental knee implant. Clin Orthop Relat Res 404:62–70CrossRef
3.
Zurück zum Zitat Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
4.
Zurück zum Zitat Faour-Martín O, Valverde-García JA, Martín-Ferrero MA, Vega-Castrillo A, de la Red Gallego MA, Suárez de Puga CC, Amigo-Liñares L (2013) Oxford phase 3 unicondylar knee arthroplasty through a minimally invasive approach: long-term results. Int Orthop 37(5):833–838CrossRefPubMedPubMedCentral Faour-Martín O, Valverde-García JA, Martín-Ferrero MA, Vega-Castrillo A, de la Red Gallego MA, Suárez de Puga CC, Amigo-Liñares L (2013) Oxford phase 3 unicondylar knee arthroplasty through a minimally invasive approach: long-term results. Int Orthop 37(5):833–838CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Fisher DA, Watts M, Davis KE (2003) Implant position in knee surgery: a comparison of minimally invasive, open unicompartmental, and total knee arthroplasty. J Arthroplast 18(7 Suppl 1):2–8CrossRef Fisher DA, Watts M, Davis KE (2003) Implant position in knee surgery: a comparison of minimally invasive, open unicompartmental, and total knee arthroplasty. J Arthroplast 18(7 Suppl 1):2–8CrossRef
6.
Zurück zum Zitat Gulati A, Weston-Simons S, Evans D, Jenkins C, Gray H, Dodd CA, Pandit H, Murray DW (2014) Radiographic evaluation of factors affecting bearing dislocation in the domed lateral Oxford unicompartmental knee replacement. Knee 21(6):1254–1257CrossRefPubMed Gulati A, Weston-Simons S, Evans D, Jenkins C, Gray H, Dodd CA, Pandit H, Murray DW (2014) Radiographic evaluation of factors affecting bearing dislocation in the domed lateral Oxford unicompartmental knee replacement. Knee 21(6):1254–1257CrossRefPubMed
7.
Zurück zum Zitat Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165CrossRef Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165CrossRef
8.
Zurück zum Zitat Huang TW, Peng KT, Huang KC, Lee MS, Hsu RW (2014) Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(12):2954–2961CrossRefPubMed Huang TW, Peng KT, Huang KC, Lee MS, Hsu RW (2014) Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(12):2954–2961CrossRefPubMed
9.
Zurück zum Zitat Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Jt Surg Br 88:44–48CrossRef Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Jt Surg Br 88:44–48CrossRef
10.
Zurück zum Zitat Kort NP, van Raay JJ, Cheung J, Jolink C, Deutman R (2007) Analysis of Oxford medial unicompartmental knee replacement using the minimally invasive technique in patients aged 60 and above: an independent prospective series. Knee Surg Sports Traumatol Arthrosc 15(11):1331–1334CrossRefPubMedPubMedCentral Kort NP, van Raay JJ, Cheung J, Jolink C, Deutman R (2007) Analysis of Oxford medial unicompartmental knee replacement using the minimally invasive technique in patients aged 60 and above: an independent prospective series. Knee Surg Sports Traumatol Arthrosc 15(11):1331–1334CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Kort NP, van Raay JJ, Thomassen BJ (2007) Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: a study in 10 cadaver femora. Knee 14:280–283CrossRefPubMed Kort NP, van Raay JJ, Thomassen BJ (2007) Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: a study in 10 cadaver femora. Knee 14:280–283CrossRefPubMed
12.
Zurück zum Zitat Lim HC, Bae JH, Song SH, Kim SJ (2012) Oxford phase 3 unicompartmental knee replacement in Korean patients. J Bone Jt Surg Br 94(8):1071–1076CrossRef Lim HC, Bae JH, Song SH, Kim SJ (2012) Oxford phase 3 unicompartmental knee replacement in Korean patients. J Bone Jt Surg Br 94(8):1071–1076CrossRef
13.
Zurück zum Zitat Ma B, Long W, Rudan JF, Ellis RE (2006) Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. J Arthroplasty 21(2):271–278CrossRefPubMed Ma B, Long W, Rudan JF, Ellis RE (2006) Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. J Arthroplasty 21(2):271–278CrossRefPubMed
14.
Zurück zum Zitat Mayman DJ, Rudan J, Watson D, Ellis R (2004) Computer-enhanced insertion of the Oxford unicompartmental arthroplasty: a fluoroguide technique. Comput Aided Surg 9:81–85CrossRefPubMed Mayman DJ, Rudan J, Watson D, Ellis R (2004) Computer-enhanced insertion of the Oxford unicompartmental arthroplasty: a fluoroguide technique. Comput Aided Surg 9:81–85CrossRefPubMed
15.
Zurück zum Zitat Murray DW, Goodfellow JW, O’Connor JJ (1998) The Oxford medial unicompartmental arthroplasty: a ten year survival study. J Bone Jt Surg Br 80:983–989CrossRef Murray DW, Goodfellow JW, O’Connor JJ (1998) The Oxford medial unicompartmental arthroplasty: a ten year survival study. J Bone Jt Surg Br 80:983–989CrossRef
16.
Zurück zum Zitat Murray DW, Goodfellow JW, O’Connor JJ, Dodd CA (1999) Oxford unicompartmental knee: manual of the surgical technique. Biomet UK Ltd, Bridgend, pp 1–40 Murray DW, Goodfellow JW, O’Connor JJ, Dodd CA (1999) Oxford unicompartmental knee: manual of the surgical technique. Biomet UK Ltd, Bridgend, pp 1–40
17.
Zurück zum Zitat Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Jt Surg Br 88(1):54–60CrossRef Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Jt Surg Br 88(1):54–60CrossRef
18.
Zurück zum Zitat Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140CrossRefPubMed Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140CrossRefPubMed
19.
Zurück zum Zitat Skowroński J, Jatskewych J, Długosz J, Skowroński R, Bielecki M (2005) The Oxford II medial unicompartmental knee replacement. A minimum 10-year follow-up study. Ortop Traumatol Rehabil 7(6):620–625PubMed Skowroński J, Jatskewych J, Długosz J, Skowroński R, Bielecki M (2005) The Oxford II medial unicompartmental knee replacement. A minimum 10-year follow-up study. Ortop Traumatol Rehabil 7(6):620–625PubMed
20.
Zurück zum Zitat Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Jt Surg Am 84:90–98CrossRef Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Jt Surg Am 84:90–98CrossRef
21.
Zurück zum Zitat Svärd VC, Price AJ (2001) Oxford medial unicompartmental arthroplasty: a survival analysis of an independent series. J Bone Jt Surg Br 83:191–194CrossRef Svärd VC, Price AJ (2001) Oxford medial unicompartmental arthroplasty: a survival analysis of an independent series. J Bone Jt Surg Br 83:191–194CrossRef
22.
Zurück zum Zitat Tu Y, Xue H, Cai M, Ma T, Liu X, Xia Z (2014) Improvement of femoral component size prediction using a C-arm intensifier guide and our established algorithm in unicompartmental knee arthroplasty: a report from a Chinese population. Knee 21(2):435–438CrossRefPubMed Tu Y, Xue H, Cai M, Ma T, Liu X, Xia Z (2014) Improvement of femoral component size prediction using a C-arm intensifier guide and our established algorithm in unicompartmental knee arthroplasty: a report from a Chinese population. Knee 21(2):435–438CrossRefPubMed
23.
Zurück zum Zitat Vasso M, Del Regno C, D’Amelio A, Viggiano D, Corona K, Schiavone Panni A (2015) Minor varus alignment provides better results than neutral alignment in medial UKA. Knee 22(2):117–121CrossRefPubMed Vasso M, Del Regno C, D’Amelio A, Viggiano D, Corona K, Schiavone Panni A (2015) Minor varus alignment provides better results than neutral alignment in medial UKA. Knee 22(2):117–121CrossRefPubMed
24.
Zurück zum Zitat Yoshida K, Tada M, Yoshida H, Takei S, Fukuoka S, Nakamura H (2013) Oxford phase 3 unicompartmental knee arthroplasty in Japan—clinical results in greater than one thousand cases over ten years. J Arthroplasty 28(9 Suppl):168–171CrossRefPubMed Yoshida K, Tada M, Yoshida H, Takei S, Fukuoka S, Nakamura H (2013) Oxford phase 3 unicompartmental knee arthroplasty in Japan—clinical results in greater than one thousand cases over ten years. J Arthroplasty 28(9 Suppl):168–171CrossRefPubMed
Metadaten
Titel
Superior femoral component alignment can be achieved with Oxford microplasty instrumentation after minimally invasive unicompartmental knee arthroplasty
verfasst von
Yihui Tu
Huaming Xue
Tong Ma
Tao Wen
Tao Yang
Hui Zhang
Minwei Cai
Publikationsdatum
25.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2017
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4173-3

Weitere Artikel der Ausgabe 3/2017

Knee Surgery, Sports Traumatology, Arthroscopy 3/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.