Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2017

26.06.2017 | Knee

Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty

verfasst von: Omer Slevin, Florian A. Schmid, Filippo-Franco Schiapparelli, Helmut Rasch, Felix Amsler, Michael T. Hirschmann

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

As patellar tracking and loading is influenced by tibial tuberosity and trochlear groove (TT–TG) distance, patellar height, thickness and tilt as well as TKA component position, it was our hypothesis that these parameters significantly correlate with patellar BTU intensity and localization in SPECT/CT. The purpose of the study was to investigate whether TKA component position as well as the height, thickness and tilt of the unresurfaced patella influences the intensity and the distribution pattern of BTU in SPECT/CT.

Methods

A total of 62 consecutive patients who underwent primary TKA without patellar resurfacing were prospectively included. Demographic data such as age, gender, side and type of primary TKA were noted. All patients underwent clinical and radiological examination in a specialized knee clinic, including standardized radiographs (anterior–posterior and lateral weight bearing, patellar skyline view) and Tc-99m-HDP-SPECT/CT before, 12 and 24 months after TKA. SPECT/CT images were analysed on 3D reconstructed images. Rotational, sagittal and coronal position of the tibial and femoral TKA components was assessed using a previously validated analysis software. Measurements of BTU including intensity and anatomical distribution pattern were also performed from 3D data. The patellar height, thickness and tilt were measured, and the distance between TT and TG was measured using axial CT images. Univariate analysis was performed to identify any correlations between BTU and TKA component position and patellar measurements (p < 0.05).

Results

The highest median BTU was measured in the superior posterior parts of the patella. A statistically significant correlation was found between valgus alignment of the femoral TKA and increased BTU at the lateral patellar regions (p < 0.05). External rotation of the tibial TKA correlated with increased BTU at the lateral superior joint adjacent part (p < 0.05). No correlation was found between the tibial TKA position (varus–valgus, anterior and posterior slope), TT–TG distance, patellar height and patellar BTU values.

Conclusions

A significant correlation of increased patellar BTU was found with femoral valgus TKA alignment. These findings highlight the importance of femoral TKA position in coronal plane with regard to post-operative patellar tracking. Moreover, these facts might explain anterior knee pain in unhappy TKA with femoral valgus alignment.

Level of evidence

Diagnostic study, Level II.
Literatur
1.
Zurück zum Zitat Ahmad R, Senthil Kumar G, Katam K, Dunlop D, Pozo JL (2009) Significance of a “hot patella” in total knee replacement without primary patellar resurfacing. Knee 16:337–340CrossRefPubMed Ahmad R, Senthil Kumar G, Katam K, Dunlop D, Pozo JL (2009) Significance of a “hot patella” in total knee replacement without primary patellar resurfacing. Knee 16:337–340CrossRefPubMed
2.
Zurück zum Zitat Awengen R, Rasch H, Amsler F, Hirschmann MT (2016) Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging 43:762–772CrossRefPubMed Awengen R, Rasch H, Amsler F, Hirschmann MT (2016) Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging 43:762–772CrossRefPubMed
3.
Zurück zum Zitat Bell SW, Young P, Drury C, Smith J, Anthony I, Jones B, Blyth M, McLean A (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee 21:272–277CrossRefPubMed Bell SW, Young P, Drury C, Smith J, Anthony I, Jones B, Blyth M, McLean A (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee 21:272–277CrossRefPubMed
4.
Zurück zum Zitat Burnett RS, Haydon Christopher M, Rorabeck CH, Bourne RB (2004) The John Insall award: patella resurfacing versus nonresurfacing in total knee arthroplasty: results of a randomized controlled clinical trial at a minimum of 10 years’ followup. Clin Orthop Relat Res 18:12–25CrossRef Burnett RS, Haydon Christopher M, Rorabeck CH, Bourne RB (2004) The John Insall award: patella resurfacing versus nonresurfacing in total knee arthroplasty: results of a randomized controlled clinical trial at a minimum of 10 years’ followup. Clin Orthop Relat Res 18:12–25CrossRef
5.
Zurück zum Zitat Dejour H, Walch G, Nove-Josserand L, Guier C (1994) Factors of patellar instability: an anatomic radiographic study. Knee Surg Sports Traumatol Arthrosc 2:19–26CrossRefPubMed Dejour H, Walch G, Nove-Josserand L, Guier C (1994) Factors of patellar instability: an anatomic radiographic study. Knee Surg Sports Traumatol Arthrosc 2:19–26CrossRefPubMed
6.
Zurück zum Zitat Fogelman I, Mckillop JH (1983) The “Hot Patella” sign: is it of any clinical significance? Concise communication. J Nucl Med 24:312–316PubMed Fogelman I, Mckillop JH (1983) The “Hot Patella” sign: is it of any clinical significance? Concise communication. J Nucl Med 24:312–316PubMed
7.
Zurück zum Zitat Forrer F, Hirschmann MT, Rasch HF (2014) July) SPECT/CT for the assessment of painful knee prosthesis. Nucl Med Commun 35(7):782CrossRefPubMed Forrer F, Hirschmann MT, Rasch HF (2014) July) SPECT/CT for the assessment of painful knee prosthesis. Nucl Med Commun 35(7):782CrossRefPubMed
8.
Zurück zum Zitat Grelsamer RP, Meadows S (1992) The modified Insall-Salvati ratio for assessment of patellar height. Clin Orthop Relat Res 282:170–176 Grelsamer RP, Meadows S (1992) The modified Insall-Salvati ratio for assessment of patellar height. Clin Orthop Relat Res 282:170–176
9.
Zurück zum Zitat Heyse TJ, Figiel J, Hähnlein U, Timmesfeld N, Schofer MD, Fuchs-Winkelmann S, Efe T (2013) MRI after patellofemoral replacement: the Component-bone interface and rotational alignment. HSS J 9:108–112CrossRefPubMedPubMedCentral Heyse TJ, Figiel J, Hähnlein U, Timmesfeld N, Schofer MD, Fuchs-Winkelmann S, Efe T (2013) MRI after patellofemoral replacement: the Component-bone interface and rotational alignment. HSS J 9:108–112CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882CrossRefPubMed Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882CrossRefPubMed
11.
Zurück zum Zitat Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF (2011) Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop 35:675–680CrossRefPubMed Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF (2011) Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop 35:675–680CrossRefPubMed
12.
Zurück zum Zitat Hirschmann MT, Henckel J, Rasch H (2013) SPECT/CT in patients with painful knee arthroplasty-what is the evidence? Skeletal Radiol 42:1201–1207CrossRefPubMed Hirschmann MT, Henckel J, Rasch H (2013) SPECT/CT in patients with painful knee arthroplasty-what is the evidence? Skeletal Radiol 42:1201–1207CrossRefPubMed
13.
Zurück zum Zitat Hirschmann MT, Iranpour F, Davda K, Rasch H, Hügli R, Friederich NF (2010) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc 18:341–345CrossRefPubMed Hirschmann MT, Iranpour F, Davda K, Rasch H, Hügli R, Friederich NF (2010) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc 18:341–345CrossRefPubMed
14.
Zurück zum Zitat Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944CrossRefPubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944CrossRefPubMed
15.
Zurück zum Zitat Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36CrossRefPubMedPubMedCentral Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Hirschmann MT, Wagner CR, Rasch H, Henckel J (2012) Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging 12(1):5CrossRefPubMedPubMedCentral Hirschmann MT, Wagner CR, Rasch H, Henckel J (2012) Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging 12(1):5CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Keshmiri A, Springorum HR, Baier C, Zeman F, Grifka J, Maderbacher G (2016) Changes in sagittal component alignment alters patellar kinematics in TKA: an in vitro study. Knee Surg Sports Traumatol Arthrosc 24:823–829CrossRefPubMed Keshmiri A, Springorum HR, Baier C, Zeman F, Grifka J, Maderbacher G (2016) Changes in sagittal component alignment alters patellar kinematics in TKA: an in vitro study. Knee Surg Sports Traumatol Arthrosc 24:823–829CrossRefPubMed
18.
19.
Zurück zum Zitat Li S, Chen Y, Su W, Zhao J, He S, Luo X (2011) Systematic review of patellar resurfacing in total knee arthroplasty. Int Orthop 35:305–316CrossRefPubMed Li S, Chen Y, Su W, Zhao J, He S, Luo X (2011) Systematic review of patellar resurfacing in total knee arthroplasty. Int Orthop 35:305–316CrossRefPubMed
20.
Zurück zum Zitat Lorberboym M, Ben Ami D, Zin D, Nikolov G, Adar E (2003) Incremental diagnostic value of 99mTc methylene diphosphonate bone SPECT in patients with patellofemoral pain disorders. Nucl Med Commun 24:403–410CrossRefPubMed Lorberboym M, Ben Ami D, Zin D, Nikolov G, Adar E (2003) Incremental diagnostic value of 99mTc methylene diphosphonate bone SPECT in patients with patellofemoral pain disorders. Nucl Med Commun 24:403–410CrossRefPubMed
21.
Zurück zum Zitat Malo M, Vince KG (2003) The unstable patella after total knee arthroplasty: etiology, prevention, and management. J Am Acad Orthop Surg 11:364–371CrossRefPubMed Malo M, Vince KG (2003) The unstable patella after total knee arthroplasty: etiology, prevention, and management. J Am Acad Orthop Surg 11:364–371CrossRefPubMed
22.
Zurück zum Zitat Pavlou G, Meyer C, Leonidou A, As-Sultany M, West R, Tsiridis E (2011) Patellar resurfacing in total knee arthroplasty: does design matter?: a meta-analysis of 7075 cases. J Bone Joint Surg Am 93:1301–1309CrossRefPubMed Pavlou G, Meyer C, Leonidou A, As-Sultany M, West R, Tsiridis E (2011) Patellar resurfacing in total knee arthroplasty: does design matter?: a meta-analysis of 7075 cases. J Bone Joint Surg Am 93:1301–1309CrossRefPubMed
23.
Zurück zum Zitat Petersen W, Rembitzki IV, Brüggemann G-P, Ellermann A, Best R, Koppenburg AG-, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38:319–328CrossRefPubMed Petersen W, Rembitzki IV, Brüggemann G-P, Ellermann A, Best R, Koppenburg AG-, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38:319–328CrossRefPubMed
24.
Zurück zum Zitat Phillips CL, Silver DA, Schranz PJ, Mandalia V (2010) The measurement of patellar height: a review of the methods of imaging. J Bone Joint Surg Br 92:1045–1053CrossRefPubMed Phillips CL, Silver DA, Schranz PJ, Mandalia V (2010) The measurement of patellar height: a review of the methods of imaging. J Bone Joint Surg Br 92:1045–1053CrossRefPubMed
25.
Zurück zum Zitat Pilling RWD, Moulder E, Allgar V, Messner J, Mohsen A (2012) Patellar resurfacing in primary total knee replacement. J Bone Joint Surg Am 94:2270–2278CrossRefPubMed Pilling RWD, Moulder E, Allgar V, Messner J, Mohsen A (2012) Patellar resurfacing in primary total knee replacement. J Bone Joint Surg Am 94:2270–2278CrossRefPubMed
26.
Zurück zum Zitat Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol 42:1215–1223CrossRef Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol 42:1215–1223CrossRef
27.
Zurück zum Zitat Sasaki T, Yagi T (1986) Subluxation of the patella. Investigation by computerized tomography. Int Orthop 10:115–120CrossRef Sasaki T, Yagi T (1986) Subluxation of the patella. Investigation by computerized tomography. Int Orthop 10:115–120CrossRef
28.
Zurück zum Zitat Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed
29.
Zurück zum Zitat Schön SN, Afifi FK, Rasch H, Amsler F, Friederich NF, Arnold MP, Hirschmann MT (2014) Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT. Knee Surg Sports Traumatol Arthrosc 22:3039–3046CrossRefPubMed Schön SN, Afifi FK, Rasch H, Amsler F, Friederich NF, Arnold MP, Hirschmann MT (2014) Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT. Knee Surg Sports Traumatol Arthrosc 22:3039–3046CrossRefPubMed
30.
Zurück zum Zitat Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral contact forces. J Biomech 27:1059–1065CrossRefPubMed Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral contact forces. J Biomech 27:1059–1065CrossRefPubMed
31.
Zurück zum Zitat Slevin O, Amsler F, Hirschmann MT (2017) No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4400-y Slevin O, Amsler F, Hirschmann MT (2017) No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4400-y
32.
Zurück zum Zitat Smith SL, Wastie ML, Forster I (2001) Radionuclide Bone Scintigraphy in the Detection of Significant Complications after Total Knee Joint Replacement. Clin Radiol 56:221–224CrossRefPubMed Smith SL, Wastie ML, Forster I (2001) Radionuclide Bone Scintigraphy in the Detection of Significant Complications after Total Knee Joint Replacement. Clin Radiol 56:221–224CrossRefPubMed
Metadaten
Titel
Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty
verfasst von
Omer Slevin
Florian A. Schmid
Filippo-Franco Schiapparelli
Helmut Rasch
Felix Amsler
Michael T. Hirschmann
Publikationsdatum
26.06.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2017
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4627-2

Weitere Artikel der Ausgabe 11/2017

Knee Surgery, Sports Traumatology, Arthroscopy 11/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.