01.05.2007 | Original Article

A valsalvometer can be effective in standardising the Valsalva manoeuvre

verfasst von: H. P. Greenland, G. L. Hosker, A. R. B. Smith

Erschienen in: International Urogynecology Journal | Ausgabe 5/2007

Einloggen, um Zugang zu erhalten

Abstract

A prospective randomised controlled study was performed in order to study the effectiveness of a device designed to reduce the variability in intra-abdominal pressures generated by individuals performing the Valsalva manoeuvre. One hundred women were recruited to take part in the project which compared a traditional Valsalva manoeuvre following standardised verbal instruction with forced expiration through a flow restriction device called a ‘valsalvometer’. The abdominal pressure was measured using an air-filled rectal balloon catheter linked to a pressure transducer. The use of the valsalvometer was associated with a reduction in variation of intra-abdominal pressure between women to 50% of the standard deviation. The new device has the capacity to reduce the variation in intra-abdominal pressure produced when performing the Valsalva manoeuvre. The rise in intra-abdominal pressure may act as a standard against which other measurements are made.
Literatur
1.
Zurück zum Zitat King J, Neville J (2005) Measurement of bladder neck mobility using perineal ultrasound. International Urogynecology Association, 16(suppl 2):abstract King J, Neville J (2005) Measurement of bladder neck mobility using perineal ultrasound. International Urogynecology Association, 16(suppl 2):abstract
2.
Zurück zum Zitat Tunn R et al (2005) Updated recommendations on ultrasonography in urogynecology. Int Urogynecol J Pelvic Floor Dysfunct 16(3):236–241PubMedCrossRef Tunn R et al (2005) Updated recommendations on ultrasonography in urogynecology. Int Urogynecol J Pelvic Floor Dysfunct 16(3):236–241PubMedCrossRef
3.
Zurück zum Zitat Greenland H et al (2001) The reproducibility of the Valsalva manoeuvre—poster presentation. In: International Continence Society, UK Division. Manchester, UK Greenland H et al (2001) The reproducibility of the Valsalva manoeuvre—poster presentation. In: International Continence Society, UK Division. Manchester, UK
4.
Zurück zum Zitat Greenland H et al (2003) Can the valsalva manoeuvre be standardised? Neurourol Urodyn 22(5):357–548CrossRef Greenland H et al (2003) Can the valsalva manoeuvre be standardised? Neurourol Urodyn 22(5):357–548CrossRef
5.
Zurück zum Zitat Bidmead J et al (2001) The “Valsalvometer”—a simple non–invasive method for producing a standardised rise in intra–abdominal pressure (Poster presentation). In: Neurourology and Urodynamics Proceedings of the International Continence Society, 20(4):493 Bidmead J et al (2001) The “Valsalvometer”—a simple non–invasive method for producing a standardised rise in intra–abdominal pressure (Poster presentation). In: Neurourology and Urodynamics Proceedings of the International Continence Society, 20(4):493
6.
Zurück zum Zitat King JK, Freeman RM (1998) Is antenatal bladder neck mobility a risk factor for postpartum stress incontinence? Br J Obstet Gynaecol 105(12):1300–1307PubMed King JK, Freeman RM (1998) Is antenatal bladder neck mobility a risk factor for postpartum stress incontinence? Br J Obstet Gynaecol 105(12):1300–1307PubMed
Metadaten
Titel
A valsalvometer can be effective in standardising the Valsalva manoeuvre
verfasst von
H. P. Greenland
G. L. Hosker
A. R. B. Smith
Publikationsdatum
01.05.2007
Verlag
Springer-Verlag
Erschienen in
International Urogynecology Journal / Ausgabe 5/2007
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-006-0186-7

Weitere Artikel der Ausgabe 5/2007

International Urogynecology Journal 5/2007 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.