Skip to main content
Erschienen in: Calcified Tissue International 4/2007

01.10.2007

An Automated Algorithm to Detect the Trabecular-Cortical Bone Interface in Micro-Computed Tomographic Images

verfasst von: Svetlana Lublinsky, Engin Ozcivici, Stefan Judex

Erschienen in: Calcified Tissue International | Ausgabe 4/2007

Einloggen, um Zugang zu erhalten

Abstract

Micro-computed tomography (microCT) has become a standard tool for the evaluation of bone morphology in preclinical studies. Unfortunately, the user-dependent definition of contour lines that separate trabecular from cortical bone is not only extremely time-consuming but may also represent a source of data bias and increased variability. Here, an automated image segmentation technique was developed and tested over a large range of bone phenotypes. The principal steps of the algorithm involve blurring, segmentation at different thresholds, and volumetric component labeling to first identify the periosteal edge and then create a cortical mask, the inner edge of which defines the trabecular-cortical interface. The algorithm was tested against (1) eight skilled microCT operators who manually defined the trabecular bone within the distal femur of four adult mice as well as (2) contour lines drawn by a single user in femurs from 71 rodents. Across the four femurs, the coefficient of variation between users was 9% for bone volume fraction, 13% for connectivity density, and 3% for trabecular thickness. Morphometric data produced by the algorithm were within 2% of the mean values of the eight operators. Across the 71 femurs, the slope and intercept of the regressions between morphometric automatic and user data were, with the exception of trabecular thickness, not significantly different from 1 and 0, respectively. Because of the excellent match with the current gold-standard technique, this algorithm may present a valuable tool for the standardized and automated evaluation of bone morphology without the time-consuming task of drawing contour lines.
Literatur
1.
Zurück zum Zitat Birkenhager-Frenkel DH, Courpron P, Hupscher EA, Clermonts E, Coutinho MF, Schmitz PI, Meunier PJ (1988) Age-related changes in cancellous bone structure. A two-dimensional study in the transiliac and iliac crest biopsy sites. Bone Miner 4:197–216PubMed Birkenhager-Frenkel DH, Courpron P, Hupscher EA, Clermonts E, Coutinho MF, Schmitz PI, Meunier PJ (1988) Age-related changes in cancellous bone structure. A two-dimensional study in the transiliac and iliac crest biopsy sites. Bone Miner 4:197–216PubMed
2.
Zurück zum Zitat Feldkamp LA, Goldstein SA, Parfitt AM, Jesion G, Kleerekoper M (1989) The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 4:3–11PubMedCrossRef Feldkamp LA, Goldstein SA, Parfitt AM, Jesion G, Kleerekoper M (1989) The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 4:3–11PubMedCrossRef
3.
Zurück zum Zitat Muller R, Hildebrand T, Ruegsegger P (1994) Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone. Phys Med Biol 39:145–164PubMedCrossRef Muller R, Hildebrand T, Ruegsegger P (1994) Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone. Phys Med Biol 39:145–164PubMedCrossRef
4.
Zurück zum Zitat Ruegsegger P, Koller B, Muller R (1996) A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 58:24–29PubMedCrossRef Ruegsegger P, Koller B, Muller R (1996) A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 58:24–29PubMedCrossRef
5.
Zurück zum Zitat Judex S, Boyd S, Qin YX, Turner S, Ye K, Muller R, Rubin C (2003) Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load. Ann Biomed Eng 31:12–20PubMedCrossRef Judex S, Boyd S, Qin YX, Turner S, Ye K, Muller R, Rubin C (2003) Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load. Ann Biomed Eng 31:12–20PubMedCrossRef
6.
Zurück zum Zitat Judex S, Garman R, Squire M, Donahue LR, Rubin C (2004) Genetically based influences on the site-specific regulation of trabecular and cortical bone morphology. J Bone Miner Res 19:600–606PubMedCrossRef Judex S, Garman R, Squire M, Donahue LR, Rubin C (2004) Genetically based influences on the site-specific regulation of trabecular and cortical bone morphology. J Bone Miner Res 19:600–606PubMedCrossRef
7.
Zurück zum Zitat Judex S, Lei X, Han D, Rubin C (2006) Low-magnitude mechanical signals that stimulate bone formation in the ovariectomized rat are dependent on the applied frequency but not on the strain magnitude. J Biomech 40:1333–1339PubMedCrossRef Judex S, Lei X, Han D, Rubin C (2006) Low-magnitude mechanical signals that stimulate bone formation in the ovariectomized rat are dependent on the applied frequency but not on the strain magnitude. J Biomech 40:1333–1339PubMedCrossRef
8.
Zurück zum Zitat Ulrich D, Hildebrand T, Van Rietbergen B, Muller R, Ruegsegger P (1997) The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. Stud Health Technol Inform 40:97–112PubMed Ulrich D, Hildebrand T, Van Rietbergen B, Muller R, Ruegsegger P (1997) The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. Stud Health Technol Inform 40:97–112PubMed
9.
Zurück zum Zitat Muller R, Van Campenhout H, Van Damme B, Van Der Perre G, Dequeker J, Hildebrand T, Ruegsegger P (1998) Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. Bone 23:59–66PubMedCrossRef Muller R, Van Campenhout H, Van Damme B, Van Der Perre G, Dequeker J, Hildebrand T, Ruegsegger P (1998) Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. Bone 23:59–66PubMedCrossRef
10.
Zurück zum Zitat Dufresne T (1998) Segmentation techniques for analysis of bone by three-dimensional computed tomographic imaging. Technol Health Care 6:351–359PubMed Dufresne T (1998) Segmentation techniques for analysis of bone by three-dimensional computed tomographic imaging. Technol Health Care 6:351–359PubMed
11.
Zurück zum Zitat Laib A, Barou O, Vico L, Lafage-Proust MH, Alexandre C, Rugsegger P (2000) 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis. Med Biol Eng Comput 38:326–332PubMedCrossRef Laib A, Barou O, Vico L, Lafage-Proust MH, Alexandre C, Rugsegger P (2000) 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis. Med Biol Eng Comput 38:326–332PubMedCrossRef
12.
Zurück zum Zitat Hildebrand T, Laib A, Muller R, Dequeker J, Ruegsegger P (1999) Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res 14:1167–1174PubMedCrossRef Hildebrand T, Laib A, Muller R, Dequeker J, Ruegsegger P (1999) Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res 14:1167–1174PubMedCrossRef
13.
Zurück zum Zitat Hildebrand T, Ruegsegger P (1997) Quantification of bone microarchitecture with the structure model index. Comput Methods Biomech Biomed Engin 1:15–23PubMedCrossRef Hildebrand T, Ruegsegger P (1997) Quantification of bone microarchitecture with the structure model index. Comput Methods Biomech Biomed Engin 1:15–23PubMedCrossRef
14.
Zurück zum Zitat Odgaard A, Gundersen HJ (1993) Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. Bone 14:173–182PubMedCrossRef Odgaard A, Gundersen HJ (1993) Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. Bone 14:173–182PubMedCrossRef
15.
Zurück zum Zitat Dewitte K, Fierens C, Stockl D, Thienpont LM (2002) Application of the Bland-Altman plot for interpretation of method-comparison studies: a critical investigation of its practice. Clin Chem 48:799–801PubMed Dewitte K, Fierens C, Stockl D, Thienpont LM (2002) Application of the Bland-Altman plot for interpretation of method-comparison studies: a critical investigation of its practice. Clin Chem 48:799–801PubMed
16.
Zurück zum Zitat Scott LE, Galpin JS, Glencross DK (2003) Multiple method comparison: statistical model using percentage similarity. Cytometry B Clin Cytom 54:46–53PubMedCrossRef Scott LE, Galpin JS, Glencross DK (2003) Multiple method comparison: statistical model using percentage similarity. Cytometry B Clin Cytom 54:46–53PubMedCrossRef
Metadaten
Titel
An Automated Algorithm to Detect the Trabecular-Cortical Bone Interface in Micro-Computed Tomographic Images
verfasst von
Svetlana Lublinsky
Engin Ozcivici
Stefan Judex
Publikationsdatum
01.10.2007
Verlag
Springer-Verlag
Erschienen in
Calcified Tissue International / Ausgabe 4/2007
Print ISSN: 0171-967X
Elektronische ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-007-9063-8

Weitere Artikel der Ausgabe 4/2007

Calcified Tissue International 4/2007 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.