Skip to main content
Erschienen in: Calcified Tissue International 2/2013

01.02.2013 | Original Research

Vitamin D Assays: Past and Present Debates, Difficulties, and Developments

verfasst von: William D. Fraser, Anna M. Milan

Erschienen in: Calcified Tissue International | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

Clinical interest in Vitamin D and its purported roles not only in calcium and bone metabolism but in several other medical conditions (diabetes, cardiovascular disease, multiple sclerosis, cancer, psychiatric disorders, neuro-muscular disease) has led to a surge in laboratory requests for 25 hydroxy vitamin D and 1,25 dihydroxy vitamin D measurement. Circulating 25 hydroxy vitamin D concentration is routinely used as the best indicator of vitamin D status, but measurement of other metabolites, especially the physiologically active 1,25 dihyroxy vitamin D, are of clinical value. Over the last 40 years the development of assays for vitamin D and its metabolites from early competitive binding assays through to immunoassay and liquid chromatography aligned to mass spectrometry have demonstrated various analytical challenges, the advantages and disadvantages of each method are constantly changing with new technological developments. Immunoassay remains the predominant mode of measurement for 25-hydroxy vitamin D although problems with equimolar recovery of the D2 and D3 metabolites remain an issue. Standardisation of all assays has been improved but not resolved with the currently available reference materials as evidenced by the international vitamin D external quality assurance scheme, DEQAS. The choice of method for each laboratory remains a balance mainly between turn around time, convenience, cost and the specificity and accuracy of the information obtained. With increasing discussion and clinical interest surrounding other vitamin D metabolites the vitamin D assay debate is set to continue.
Literatur
1.
Zurück zum Zitat Bouillon R, Okamura WH, Norman AW (1995) Structure–function relationships in the vitamin D endocrine system. Endocr Rev 16:200–257PubMed Bouillon R, Okamura WH, Norman AW (1995) Structure–function relationships in the vitamin D endocrine system. Endocr Rev 16:200–257PubMed
2.
Zurück zum Zitat Clemens TL, Adams JS, Nolan JM, Holick MF (1982) Measurement of circulating vitamin D in man. Clin Chim Acta 121:301–308PubMedCrossRef Clemens TL, Adams JS, Nolan JM, Holick MF (1982) Measurement of circulating vitamin D in man. Clin Chim Acta 121:301–308PubMedCrossRef
3.
Zurück zum Zitat Barragry JM, France MW, Corless D, Gupta SP, Switala S, Boucher BJ, Cohen RD (1978) Intestinal cholecalciferol absorption in the elderly and in younger adults. Clin Sci Mol Med 55:213–220PubMed Barragry JM, France MW, Corless D, Gupta SP, Switala S, Boucher BJ, Cohen RD (1978) Intestinal cholecalciferol absorption in the elderly and in younger adults. Clin Sci Mol Med 55:213–220PubMed
4.
Zurück zum Zitat Clemens TL, Zhou XY, Myles M, Endres D, Lindsay R (1986) Serum vitamin D2 and vitamin D3 metabolite concentrations and absorption of vitamin D2 in elderly subjects. J Clin Endocrinol Metab 63:656–660PubMedCrossRef Clemens TL, Zhou XY, Myles M, Endres D, Lindsay R (1986) Serum vitamin D2 and vitamin D3 metabolite concentrations and absorption of vitamin D2 in elderly subjects. J Clin Endocrinol Metab 63:656–660PubMedCrossRef
5.
Zurück zum Zitat Gallacher SJ, Cowan RA, Fraser WD, Logue FC, Jenkins A, Boyle IT (1994) Acute effects of intravenous 1 alpha-hydroxycholecalciferol on parathyroid hormone, osteocalcin and calcitriol in man. Eur J Endocrinol 130:141–145PubMedCrossRef Gallacher SJ, Cowan RA, Fraser WD, Logue FC, Jenkins A, Boyle IT (1994) Acute effects of intravenous 1 alpha-hydroxycholecalciferol on parathyroid hormone, osteocalcin and calcitriol in man. Eur J Endocrinol 130:141–145PubMedCrossRef
6.
Zurück zum Zitat Gray RW, Caldas AE, Wilz DR, Lemann J Jr, Smith GA, DeLuca HF (1978) Metabolism and excretion of 3H–1,25-(OH)2-vitamin D3 in healthy adults. J Clin Endocrinol Metab 46:756–765PubMedCrossRef Gray RW, Caldas AE, Wilz DR, Lemann J Jr, Smith GA, DeLuca HF (1978) Metabolism and excretion of 3H–1,25-(OH)2-vitamin D3 in healthy adults. J Clin Endocrinol Metab 46:756–765PubMedCrossRef
7.
Zurück zum Zitat Jones G (2008) Pharmacokinetics of vitamin D toxicity. Am J Clin Nutr 88:582S–586SPubMed Jones G (2008) Pharmacokinetics of vitamin D toxicity. Am J Clin Nutr 88:582S–586SPubMed
8.
Zurück zum Zitat Papapoulos SE, Clemens TL, Sandler LM, Fraher LJ, Winer J, O’Riordan JL (1982) The effect of renal function on changes in circulating concentrations of 1,25-dihydroxycholecalciferol after an oral dose. Clin Sci (Lond) 62:427–429 Papapoulos SE, Clemens TL, Sandler LM, Fraher LJ, Winer J, O’Riordan JL (1982) The effect of renal function on changes in circulating concentrations of 1,25-dihydroxycholecalciferol after an oral dose. Clin Sci (Lond) 62:427–429
9.
10.
Zurück zum Zitat Shephard RM, DeLuca HF (1980) Plasma concentrations of vitamin D3 and its metabolites in the rat as influenced by vitamin D3 or 25-hydroxyvitamin D3 intakes. Arch Biochem Biophys 202:43–53PubMedCrossRef Shephard RM, DeLuca HF (1980) Plasma concentrations of vitamin D3 and its metabolites in the rat as influenced by vitamin D3 or 25-hydroxyvitamin D3 intakes. Arch Biochem Biophys 202:43–53PubMedCrossRef
11.
Zurück zum Zitat Zehnder D, Bland R, Williams MC, McNinch RW, Howie AJ, Stewart PM, Hewison M (2001) Extrarenal expression of 25-hydroxyvitamin D3–1 alpha-hydroxylase. J Clin Endocrinol Metab 86:888–894PubMedCrossRef Zehnder D, Bland R, Williams MC, McNinch RW, Howie AJ, Stewart PM, Hewison M (2001) Extrarenal expression of 25-hydroxyvitamin D3–1 alpha-hydroxylase. J Clin Endocrinol Metab 86:888–894PubMedCrossRef
12.
Zurück zum Zitat Need AG, O’Loughlin PD, Morris HA, Coates PS, Horowitz M, Nordin BE (2008) Vitamin D metabolites and calcium absorption in severe vitamin D deficiency. J Bone Miner Res 23:1859–1863PubMedCrossRef Need AG, O’Loughlin PD, Morris HA, Coates PS, Horowitz M, Nordin BE (2008) Vitamin D metabolites and calcium absorption in severe vitamin D deficiency. J Bone Miner Res 23:1859–1863PubMedCrossRef
13.
Zurück zum Zitat Haddad JG, Chyu KJ (1971) Competitive protein-binding radioassay for 25-hydroxycholecalciferol. J Clin Endocrinol Metab 33:992–995PubMedCrossRef Haddad JG, Chyu KJ (1971) Competitive protein-binding radioassay for 25-hydroxycholecalciferol. J Clin Endocrinol Metab 33:992–995PubMedCrossRef
14.
Zurück zum Zitat Bayard F, Bec P, Louvet JP (1972) Measurement of plasma 25-hydroxycholecalciferol in man. Eur J Clin Invest 2:195–198PubMedCrossRef Bayard F, Bec P, Louvet JP (1972) Measurement of plasma 25-hydroxycholecalciferol in man. Eur J Clin Invest 2:195–198PubMedCrossRef
15.
Zurück zum Zitat Belsey R, DeLuca HF, Potts JT Jr (1971) Competitive binding assay for vitamin D and 25-OH vitamin D. J Clin Endocrinol Metab 33:554–557PubMedCrossRef Belsey R, DeLuca HF, Potts JT Jr (1971) Competitive binding assay for vitamin D and 25-OH vitamin D. J Clin Endocrinol Metab 33:554–557PubMedCrossRef
16.
Zurück zum Zitat Bouillon R, Kerkhove PV, De MP (1976) Measurement of 25-hydroxyvitamin D3 in serum. Clin Chem 22:364–368PubMed Bouillon R, Kerkhove PV, De MP (1976) Measurement of 25-hydroxyvitamin D3 in serum. Clin Chem 22:364–368PubMed
17.
Zurück zum Zitat Edelstein S, Charman M, Lawson DE, Kodicek E (1974) Competitive protein-binding assay for 25-hydroxycholecalciferol. Clin Sci Mol Med 46:231–240PubMed Edelstein S, Charman M, Lawson DE, Kodicek E (1974) Competitive protein-binding assay for 25-hydroxycholecalciferol. Clin Sci Mol Med 46:231–240PubMed
18.
Zurück zum Zitat Preece MA, O’Riordan JL, Lawson DE, Kodicek E (1974) A competitive protein-binding assay for 25-hydroxycholecalciferol and 25-hydroxyergocalciferol in serum. Clin Chim Acta 54:235–242PubMedCrossRef Preece MA, O’Riordan JL, Lawson DE, Kodicek E (1974) A competitive protein-binding assay for 25-hydroxycholecalciferol and 25-hydroxyergocalciferol in serum. Clin Chim Acta 54:235–242PubMedCrossRef
19.
Zurück zum Zitat Dorantes LM, Arnaud SB, Arnaud CD (1978) Importance of the isolation of 25-hydroxyvitamin D before assay. J Lab Clin Med 91:791–796PubMed Dorantes LM, Arnaud SB, Arnaud CD (1978) Importance of the isolation of 25-hydroxyvitamin D before assay. J Lab Clin Med 91:791–796PubMed
20.
Zurück zum Zitat Glendenning P, Noble JM, Taranto M, Musk AA, McGuiness M, Goldswain PR, Fraser WD, Vasikaran SD (2003) Issues of methodology, standardization and metabolite recognition for 25-hydroxyvitamin D when comparing the DiaSorin radioimmunoassay and the Nichols Advantage automated chemiluminescence protein-binding assay in hip fracture cases. Ann Clin Biochem 40:546–551PubMedCrossRef Glendenning P, Noble JM, Taranto M, Musk AA, McGuiness M, Goldswain PR, Fraser WD, Vasikaran SD (2003) Issues of methodology, standardization and metabolite recognition for 25-hydroxyvitamin D when comparing the DiaSorin radioimmunoassay and the Nichols Advantage automated chemiluminescence protein-binding assay in hip fracture cases. Ann Clin Biochem 40:546–551PubMedCrossRef
21.
Zurück zum Zitat Glendenning P, Taranto M, Noble JM, Musk AA, Hammond C, Goldswain PR, Fraser WD, Vasikaran SD (2006) Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite-specific assays. Ann Clin Biochem 43:23–30PubMedCrossRef Glendenning P, Taranto M, Noble JM, Musk AA, Hammond C, Goldswain PR, Fraser WD, Vasikaran SD (2006) Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite-specific assays. Ann Clin Biochem 43:23–30PubMedCrossRef
22.
Zurück zum Zitat Leventis P, Garrison L, Sibley M, Peterson P, Egerton M, Levin G, Kiely P (2005) Underestimation of serum 25-hydroxyvitamin D by the Nichols Advantage Assay in patients receiving vitamin D replacement therapy. Clin Chem 51:1072–1074PubMedCrossRef Leventis P, Garrison L, Sibley M, Peterson P, Egerton M, Levin G, Kiely P (2005) Underestimation of serum 25-hydroxyvitamin D by the Nichols Advantage Assay in patients receiving vitamin D replacement therapy. Clin Chem 51:1072–1074PubMedCrossRef
23.
Zurück zum Zitat Hollis BW, Napoli JL (1985) Improved radioimmunoassay for vitamin D and its use in assessing vitamin D status. Clin Chem 31:1815–1819PubMed Hollis BW, Napoli JL (1985) Improved radioimmunoassay for vitamin D and its use in assessing vitamin D status. Clin Chem 31:1815–1819PubMed
24.
Zurück zum Zitat Hollis BW, Kamerud JQ, Selvaag SR, Lorenz JD, Napoli JL (1993) Determination of vitamin D status by radioimmunoassay with an 125I-labeled tracer. Clin Chem 39:529–533PubMed Hollis BW, Kamerud JQ, Selvaag SR, Lorenz JD, Napoli JL (1993) Determination of vitamin D status by radioimmunoassay with an 125I-labeled tracer. Clin Chem 39:529–533PubMed
25.
Zurück zum Zitat Ersfeld DL, Rao DS, Body JJ, Sackrison JL Jr, Miller AB, Parikh N, Eskridge TL, Polinske A, Olson GT, MacFarlane GD (2004) Analytical and clinical validation of the 25 OH vitamin D assay for the Liaison automated analyzer. Clin Biochem 37:867–874PubMedCrossRef Ersfeld DL, Rao DS, Body JJ, Sackrison JL Jr, Miller AB, Parikh N, Eskridge TL, Polinske A, Olson GT, MacFarlane GD (2004) Analytical and clinical validation of the 25 OH vitamin D assay for the Liaison automated analyzer. Clin Biochem 37:867–874PubMedCrossRef
26.
Zurück zum Zitat Hollis BW (2000) Comparison of commercially available 125I-based RIA methods for the determination of circulating 25-hydroxyvitamin D. Clin Chem 46:1657–1661PubMed Hollis BW (2000) Comparison of commercially available 125I-based RIA methods for the determination of circulating 25-hydroxyvitamin D. Clin Chem 46:1657–1661PubMed
27.
Zurück zum Zitat Hypponen E, Turner S, Cumberland P, Power C, Gibb I (2007) Serum 25-hydroxyvitamin D measurement in a large population survey with statistical harmonization of assay variation to an international standard. J Clin Endocrinol Metab 92:4615–4622PubMedCrossRef Hypponen E, Turner S, Cumberland P, Power C, Gibb I (2007) Serum 25-hydroxyvitamin D measurement in a large population survey with statistical harmonization of assay variation to an international standard. J Clin Endocrinol Metab 92:4615–4622PubMedCrossRef
28.
Zurück zum Zitat Heijboer AC, Blankenstein MA, Kema IP, Buijs MM (2012) Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration. Clin Chem 58:543–548PubMedCrossRef Heijboer AC, Blankenstein MA, Kema IP, Buijs MM (2012) Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration. Clin Chem 58:543–548PubMedCrossRef
29.
Zurück zum Zitat Binkley N, Krueger D, Lensmeyer G (2009) 25-hydroxyvitamin D measurement, 2009: a review for clinicians. J Clin Densitom 12:417–427PubMedCrossRef Binkley N, Krueger D, Lensmeyer G (2009) 25-hydroxyvitamin D measurement, 2009: a review for clinicians. J Clin Densitom 12:417–427PubMedCrossRef
30.
Zurück zum Zitat Binkley N, Krueger DC, Morgan S, Wiebe D (2010) Current status of clinical 25-hydroxyvitamin D measurement: an assessment of between-laboratory agreement. Clin Chim Acta 411:1976–1982PubMedCrossRef Binkley N, Krueger DC, Morgan S, Wiebe D (2010) Current status of clinical 25-hydroxyvitamin D measurement: an assessment of between-laboratory agreement. Clin Chim Acta 411:1976–1982PubMedCrossRef
31.
Zurück zum Zitat Carter GD, Carter R, Jones J, Berry J (2004) How accurate are assays for 25-hydroxyvitamin D? Data from the International Vitamin D External Quality Assessment Scheme. Clin Chem 50:2195–2197PubMedCrossRef Carter GD, Carter R, Jones J, Berry J (2004) How accurate are assays for 25-hydroxyvitamin D? Data from the International Vitamin D External Quality Assessment Scheme. Clin Chem 50:2195–2197PubMedCrossRef
32.
Zurück zum Zitat Jones G (1978) Assay of vitamins D2 and D3, and 25-hydroxyvitamins D2 and D3 in human plasma by high-performance liquid chromatography. Clin Chem 24:287–298PubMed Jones G (1978) Assay of vitamins D2 and D3, and 25-hydroxyvitamins D2 and D3 in human plasma by high-performance liquid chromatography. Clin Chem 24:287–298PubMed
33.
Zurück zum Zitat Kleerekoper M, Schleicher RL, Eisman J, Bouillon R, Singh RJ, Holick MF (2011) Clinical applications for vitamin D assays: what is known and what is wished for. Clin Chem 57:1227–1232PubMedCrossRef Kleerekoper M, Schleicher RL, Eisman J, Bouillon R, Singh RJ, Holick MF (2011) Clinical applications for vitamin D assays: what is known and what is wished for. Clin Chem 57:1227–1232PubMedCrossRef
34.
Zurück zum Zitat Coldwell RD, Trafford DJ, Makin HL, Varley MJ, Kirk DN (1984) Specific estimation of 24,25-dihydroxyvitamin D in plasma by gas chromatography-mass spectrometry. Clin Chem 30:1193–1198PubMed Coldwell RD, Trafford DJ, Makin HL, Varley MJ, Kirk DN (1984) Specific estimation of 24,25-dihydroxyvitamin D in plasma by gas chromatography-mass spectrometry. Clin Chem 30:1193–1198PubMed
35.
Zurück zum Zitat Eisman JA, Shepard RM, DeLuca HF (1977) Determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human plasma using high-pressure liquid chromatography. Anal Biochem 80:298–305PubMedCrossRef Eisman JA, Shepard RM, DeLuca HF (1977) Determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human plasma using high-pressure liquid chromatography. Anal Biochem 80:298–305PubMedCrossRef
36.
Zurück zum Zitat Gilbertson TJ, Stryd RP (1977) High-performance liquid chromatographic assay for 25-hydroxyvitamin D3 in serum. Clin Chem 23:1700–1704PubMed Gilbertson TJ, Stryd RP (1977) High-performance liquid chromatographic assay for 25-hydroxyvitamin D3 in serum. Clin Chem 23:1700–1704PubMed
37.
Zurück zum Zitat Horst RL, Reinhardt TA, Hollis BW (1990) Improved methodology for the analysis of plasma vitamin D metabolites. Kidney Int Suppl 29:S28–S35PubMed Horst RL, Reinhardt TA, Hollis BW (1990) Improved methodology for the analysis of plasma vitamin D metabolites. Kidney Int Suppl 29:S28–S35PubMed
38.
Zurück zum Zitat Liel Y, Ulmer E, Shary J, Hollis BW, Bell NH (1988) Low circulating vitamin D in obesity. Calcif Tissue Int 43:199–201PubMedCrossRef Liel Y, Ulmer E, Shary J, Hollis BW, Bell NH (1988) Low circulating vitamin D in obesity. Calcif Tissue Int 43:199–201PubMedCrossRef
39.
Zurück zum Zitat Lensmeyer GL, Wiebe DA, Binkley N, Drezner MK (2006) HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays. Clin Chem 52:1120–1126PubMedCrossRef Lensmeyer GL, Wiebe DA, Binkley N, Drezner MK (2006) HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays. Clin Chem 52:1120–1126PubMedCrossRef
40.
Zurück zum Zitat Yeung B, Vouros P, Reddy GS (1993) Characterization of vitamin D3 metabolites using continuous-flow fast atom bombardment tandem mass spectrometry and high-performance liquid chromatography. J Chromatogr 645:115–123PubMedCrossRef Yeung B, Vouros P, Reddy GS (1993) Characterization of vitamin D3 metabolites using continuous-flow fast atom bombardment tandem mass spectrometry and high-performance liquid chromatography. J Chromatogr 645:115–123PubMedCrossRef
41.
Zurück zum Zitat Maunsell Z, Wright DJ, Rainbow SJ (2005) Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3. Clin Chem 51:1683–1690PubMedCrossRef Maunsell Z, Wright DJ, Rainbow SJ (2005) Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3. Clin Chem 51:1683–1690PubMedCrossRef
42.
Zurück zum Zitat Tsugawa N, Suhara Y, Kamao M, Okano T (2005) Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography–tandem mass spectrometry. Anal Chem 77:3001–3007PubMedCrossRef Tsugawa N, Suhara Y, Kamao M, Okano T (2005) Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography–tandem mass spectrometry. Anal Chem 77:3001–3007PubMedCrossRef
43.
Zurück zum Zitat Vogeser M, Kyriatsoulis A, Huber E, Kobold U (2004) Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry. Clin Chem 50:1415–1417PubMedCrossRef Vogeser M, Kyriatsoulis A, Huber E, Kobold U (2004) Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry. Clin Chem 50:1415–1417PubMedCrossRef
44.
45.
Zurück zum Zitat Knox S, Harris J, Calton L, Wallace AM (2009) A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry. Ann Clin Biochem 46:226–230PubMedCrossRef Knox S, Harris J, Calton L, Wallace AM (2009) A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry. Ann Clin Biochem 46:226–230PubMedCrossRef
46.
Zurück zum Zitat Chen H, McCoy LF, Schleicher RL, Pfeiffer CM (2008) Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method. Clin Chim Acta 391:6–12PubMedCrossRef Chen H, McCoy LF, Schleicher RL, Pfeiffer CM (2008) Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method. Clin Chim Acta 391:6–12PubMedCrossRef
47.
Zurück zum Zitat Thibeault D, Caron N, Djiana R, Kremer R, Blank D (2012) Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE). J Chromatogr B Anal Technol Biomed Life Sci 883–884:120–127CrossRef Thibeault D, Caron N, Djiana R, Kremer R, Blank D (2012) Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE). J Chromatogr B Anal Technol Biomed Life Sci 883–884:120–127CrossRef
48.
Zurück zum Zitat Bunch DR, Miller AY, Wang S (2009) Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology. Clin Chem Lab Med 47:1565–1572PubMedCrossRef Bunch DR, Miller AY, Wang S (2009) Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology. Clin Chem Lab Med 47:1565–1572PubMedCrossRef
49.
Zurück zum Zitat Netzel BC, Cradic KW, Bro ET, Girtman AB, Cyr RC, Singh RJ, Grebe SK (2011) Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3. Clin Chem 57:431–440PubMedCrossRef Netzel BC, Cradic KW, Bro ET, Girtman AB, Cyr RC, Singh RJ, Grebe SK (2011) Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3. Clin Chem 57:431–440PubMedCrossRef
50.
Zurück zum Zitat Singh RJ, Taylor RL, Reddy GS, Grebe SK (2006) C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status. J Clin Endocrinol Metab 91:3055–3061PubMedCrossRef Singh RJ, Taylor RL, Reddy GS, Grebe SK (2006) C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status. J Clin Endocrinol Metab 91:3055–3061PubMedCrossRef
51.
Zurück zum Zitat Lensmeyer G, Poquette M, Wiebe D, Binkley N (2012) The C-3 epimer of 25-hydroxyvitamin D3 is present in adult serum. J Clin Endocrinol Metab 97:163–168PubMedCrossRef Lensmeyer G, Poquette M, Wiebe D, Binkley N (2012) The C-3 epimer of 25-hydroxyvitamin D3 is present in adult serum. J Clin Endocrinol Metab 97:163–168PubMedCrossRef
52.
53.
Zurück zum Zitat Schleicher RL, Encisco SE, Chaudhary-Webb M, Paliakov E, McCoy LF, Pfeiffer CM (2011) Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. Clin Chim Acta 412:1594–1599PubMedCrossRef Schleicher RL, Encisco SE, Chaudhary-Webb M, Paliakov E, McCoy LF, Pfeiffer CM (2011) Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. Clin Chim Acta 412:1594–1599PubMedCrossRef
54.
Zurück zum Zitat Shah I, James R, Barker J, Petroczi A, Naughton DP (2011) Misleading measures in vitamin D analysis: a novel LC-MS/MS assay to account for epimers and isobars. Nutr J 10:46PubMedCrossRef Shah I, James R, Barker J, Petroczi A, Naughton DP (2011) Misleading measures in vitamin D analysis: a novel LC-MS/MS assay to account for epimers and isobars. Nutr J 10:46PubMedCrossRef
55.
Zurück zum Zitat Stepman HC, Vanderroost A, Van UK, Thienpont LM (2011) Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 57:441–448PubMedCrossRef Stepman HC, Vanderroost A, Van UK, Thienpont LM (2011) Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 57:441–448PubMedCrossRef
56.
Zurück zum Zitat Tai SS, Bedner M, Phinney KW (2010) Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 82:1942–1948PubMedCrossRef Tai SS, Bedner M, Phinney KW (2010) Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 82:1942–1948PubMedCrossRef
57.
Zurück zum Zitat Cluse ZN, Fudge AN, Whiting MJ, McWhinney B, Parkinson I, O’Loughlin PD (2012) Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser. Ann Clin Biochem 49:159–165PubMedCrossRef Cluse ZN, Fudge AN, Whiting MJ, McWhinney B, Parkinson I, O’Loughlin PD (2012) Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser. Ann Clin Biochem 49:159–165PubMedCrossRef
58.
Zurück zum Zitat Cavalier E, Carlisi A, Bekaert AC, Rousselle O, Chapelle JP, Souberbielle JC (2012) Analytical evaluation of the new Abbott Architect 25-OH vitamin D assay. Clin Biochem 45:505–508PubMedCrossRef Cavalier E, Carlisi A, Bekaert AC, Rousselle O, Chapelle JP, Souberbielle JC (2012) Analytical evaluation of the new Abbott Architect 25-OH vitamin D assay. Clin Biochem 45:505–508PubMedCrossRef
59.
Zurück zum Zitat Cavalier E, Carlisi A, Bekaert AC, Rousselle O, Chapelle JP (2012) Human anti-animal interference in DiaSorin Liaison total 25(OH)-vitamin D assay: towards the end of a strange story? Clin Chim Acta 413:527–528PubMedCrossRef Cavalier E, Carlisi A, Bekaert AC, Rousselle O, Chapelle JP (2012) Human anti-animal interference in DiaSorin Liaison total 25(OH)-vitamin D assay: towards the end of a strange story? Clin Chim Acta 413:527–528PubMedCrossRef
60.
Zurück zum Zitat Farrell CJ, Martin S, McWhinney B, Straub I, Williams P, Herrmann M (2012) State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods. Clin Chem 58:531–542PubMedCrossRef Farrell CJ, Martin S, McWhinney B, Straub I, Williams P, Herrmann M (2012) State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods. Clin Chem 58:531–542PubMedCrossRef
61.
Zurück zum Zitat Carter GD, Jones JC (2009) Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D. Ann Clin Biochem 46:79–81PubMedCrossRef Carter GD, Jones JC (2009) Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D. Ann Clin Biochem 46:79–81PubMedCrossRef
62.
Zurück zum Zitat Fraser WD (2009) Standardization of vitamin D assays: art or science? Ann Clin Biochem 46:3–4PubMedCrossRef Fraser WD (2009) Standardization of vitamin D assays: art or science? Ann Clin Biochem 46:3–4PubMedCrossRef
63.
Zurück zum Zitat Phinney KW, Bedner M, Tai SS, Vamathevan VV, Sander LC, Sharpless KE, Wise SA, Yen JH, Schleicher RL, Chaudhary-Webb M, Pfeiffer CM, Betz JM, Coates PM, Picciano MF (2012) Development and certification of a standard reference material for vitamin D metabolites in human serum. Anal Chem 84:956–962PubMedCrossRef Phinney KW, Bedner M, Tai SS, Vamathevan VV, Sander LC, Sharpless KE, Wise SA, Yen JH, Schleicher RL, Chaudhary-Webb M, Pfeiffer CM, Betz JM, Coates PM, Picciano MF (2012) Development and certification of a standard reference material for vitamin D metabolites in human serum. Anal Chem 84:956–962PubMedCrossRef
64.
Zurück zum Zitat Carter GD, Berry JL, Gunter E, Jones G, Jones JC, Makin HL, Sufi S, Wheeler MJ (2010) Proficiency testing of 25-hydroxyvitamin D (25-OHD) assays. J Steroid Biochem Mol Biol 121:176–179PubMedCrossRef Carter GD, Berry JL, Gunter E, Jones G, Jones JC, Makin HL, Sufi S, Wheeler MJ (2010) Proficiency testing of 25-hydroxyvitamin D (25-OHD) assays. J Steroid Biochem Mol Biol 121:176–179PubMedCrossRef
65.
Zurück zum Zitat Brumbaugh PF, Haussler DH, Bressler R, Haussler MR (1974) Radioreceptor assay for 1 alpha,25-dihydroxyvitamin D3. Science 183:1089–1091PubMedCrossRef Brumbaugh PF, Haussler DH, Bressler R, Haussler MR (1974) Radioreceptor assay for 1 alpha,25-dihydroxyvitamin D3. Science 183:1089–1091PubMedCrossRef
66.
Zurück zum Zitat Reinhardt TA, Horst RL, Orf JW, Hollis BW (1984) A microassay for 1,25-dihydroxyvitamin D not requiring high performance liquid chromatography: application to clinical studies. J Clin Endocrinol Metab 58:91–98PubMedCrossRef Reinhardt TA, Horst RL, Orf JW, Hollis BW (1984) A microassay for 1,25-dihydroxyvitamin D not requiring high performance liquid chromatography: application to clinical studies. J Clin Endocrinol Metab 58:91–98PubMedCrossRef
67.
Zurück zum Zitat Clemens TL, Hendy GN, Graham RF, Baggiolini EG, Uskokovic MR, O’Riordan JL (1978) A radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Sci Mol Med 54:329–332PubMed Clemens TL, Hendy GN, Graham RF, Baggiolini EG, Uskokovic MR, O’Riordan JL (1978) A radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Sci Mol Med 54:329–332PubMed
68.
Zurück zum Zitat Bouillon R, De Moor P, Baggiolini EG, Uskokovic MR (1980) A radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Chem 26:562–567PubMed Bouillon R, De Moor P, Baggiolini EG, Uskokovic MR (1980) A radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Chem 26:562–567PubMed
69.
Zurück zum Zitat Fraher LJ, Adami S, Clemens TL, Jones G, O’Riordan JL (1983) Radioimmunoassay of 1,25-dihydroxy vitamin D2: studies on the metabolism of vitamin D2 in man. Clin Endocrinol (Oxf) 19:151–165CrossRef Fraher LJ, Adami S, Clemens TL, Jones G, O’Riordan JL (1983) Radioimmunoassay of 1,25-dihydroxy vitamin D2: studies on the metabolism of vitamin D2 in man. Clin Endocrinol (Oxf) 19:151–165CrossRef
70.
Zurück zum Zitat Gray TK, McAdoo T, Pool D, Lester GE, Williams ME, Jones G (1981) A modified radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Chem 27:458–463PubMed Gray TK, McAdoo T, Pool D, Lester GE, Williams ME, Jones G (1981) A modified radioimmunoassay for 1,25-dihydroxycholecalciferol. Clin Chem 27:458–463PubMed
71.
Zurück zum Zitat Hollis BW, Kamerud JQ, Kurkowski A, Beaulieu J, Napoli JL (1996) Quantification of circulating 1,25-dihydroxyvitamin D by radioimmunoassay with 125I-labeled tracer. Clin Chem 42:586–592PubMed Hollis BW, Kamerud JQ, Kurkowski A, Beaulieu J, Napoli JL (1996) Quantification of circulating 1,25-dihydroxyvitamin D by radioimmunoassay with 125I-labeled tracer. Clin Chem 42:586–592PubMed
72.
Zurück zum Zitat Clive DR, Sudhaker D, Giacherio D, Gupta M, Schreiber MJ, Sackrison JL, MacFarlane GD (2002) Analytical and clinical validation of a radioimmunoassay for the measurement of 1,25 dihydroxy vitamin D. Clin Biochem 35:517–521PubMedCrossRef Clive DR, Sudhaker D, Giacherio D, Gupta M, Schreiber MJ, Sackrison JL, MacFarlane GD (2002) Analytical and clinical validation of a radioimmunoassay for the measurement of 1,25 dihydroxy vitamin D. Clin Biochem 35:517–521PubMedCrossRef
73.
Zurück zum Zitat Fraser WD, Durham BH, Berry JL, Mawer EB (1997) Measurement of plasma 1,25 dihydroxyvitamin D using a novel immunoextraction technique and immunoassay with iodine labelled vitamin D tracer. Ann Clin Biochem 34(Pt 6):632–637PubMed Fraser WD, Durham BH, Berry JL, Mawer EB (1997) Measurement of plasma 1,25 dihydroxyvitamin D using a novel immunoextraction technique and immunoassay with iodine labelled vitamin D tracer. Ann Clin Biochem 34(Pt 6):632–637PubMed
74.
Zurück zum Zitat Seiden-Long I, Vieth R (2007) Evaluation of a 1,25-dihydroxyvitamin D enzyme immunoassay. Clin Chem 53:1104–1108PubMedCrossRef Seiden-Long I, Vieth R (2007) Evaluation of a 1,25-dihydroxyvitamin D enzyme immunoassay. Clin Chem 53:1104–1108PubMedCrossRef
75.
Zurück zum Zitat Hollis BW (1995) 1,25-Dihydroxyvitamin D3–26,23-lactone interferes in determination of 1,25-dihydroxyvitamin D by RIA after immunoextraction. Clin Chem 41:1313–1314PubMed Hollis BW (1995) 1,25-Dihydroxyvitamin D3–26,23-lactone interferes in determination of 1,25-dihydroxyvitamin D by RIA after immunoextraction. Clin Chem 41:1313–1314PubMed
76.
Zurück zum Zitat Bjorkhem I, Holmberg I, Kristiansen T, Pedersen JI (1979) Assay of 1,25-dihydroxy vitamin D3 by isotope dilution–mass fragmentography. Clin Chem 25:584–588PubMed Bjorkhem I, Holmberg I, Kristiansen T, Pedersen JI (1979) Assay of 1,25-dihydroxy vitamin D3 by isotope dilution–mass fragmentography. Clin Chem 25:584–588PubMed
77.
Zurück zum Zitat Vreeken RJ, Honing M, van Baar BL, Ghijsen RT, de Jong GJ, Brinkman UA (1993) On-line post-column Diels-Alder derivatization for the determination of vitamin D3 and its metabolites by liquid chromatography/thermospray mass spectrometry. Biol Mass Spectrom 22:621–632PubMedCrossRef Vreeken RJ, Honing M, van Baar BL, Ghijsen RT, de Jong GJ, Brinkman UA (1993) On-line post-column Diels-Alder derivatization for the determination of vitamin D3 and its metabolites by liquid chromatography/thermospray mass spectrometry. Biol Mass Spectrom 22:621–632PubMedCrossRef
78.
Zurück zum Zitat Kissmeyer AM, Sonne K (2001) Sensitive analysis of 1alpha,25-dihydroxyvitamin D3 in biological fluids by liquid chromatography-tandem mass spectrometry. J Chromatogr A 935:93–103PubMedCrossRef Kissmeyer AM, Sonne K (2001) Sensitive analysis of 1alpha,25-dihydroxyvitamin D3 in biological fluids by liquid chromatography-tandem mass spectrometry. J Chromatogr A 935:93–103PubMedCrossRef
79.
Zurück zum Zitat Aronov PA, Hall LM, Dettmer K, Stephensen CB, Hammock BD (2008) Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 391:1917–1930PubMedCrossRef Aronov PA, Hall LM, Dettmer K, Stephensen CB, Hammock BD (2008) Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 391:1917–1930PubMedCrossRef
80.
Zurück zum Zitat Duan X, Weinstock-Guttman B, Wang H, Bang E, Li J, Ramanathan M, Qu J (2010) Ultrasensitive quantification of serum vitamin D metabolites using selective solid-phase extraction coupled to microflow liquid chromatography and isotope-dilution mass spectrometry. Anal Chem 82:2488–2497PubMedCrossRef Duan X, Weinstock-Guttman B, Wang H, Bang E, Li J, Ramanathan M, Qu J (2010) Ultrasensitive quantification of serum vitamin D metabolites using selective solid-phase extraction coupled to microflow liquid chromatography and isotope-dilution mass spectrometry. Anal Chem 82:2488–2497PubMedCrossRef
81.
Zurück zum Zitat Casetta B, Jans I, Billen J, Vanderschueren D, Bouillon R (2010) Development of a method for the quantification of 1alpha,25(OH)2-vitamin D3 in serum by liquid chromatography tandem mass spectrometry without derivatization. Eur J Mass Spectrom (Chichester, Eng) 16(1):81–89CrossRef Casetta B, Jans I, Billen J, Vanderschueren D, Bouillon R (2010) Development of a method for the quantification of 1alpha,25(OH)2-vitamin D3 in serum by liquid chromatography tandem mass spectrometry without derivatization. Eur J Mass Spectrom (Chichester, Eng) 16(1):81–89CrossRef
82.
Zurück zum Zitat Yuan C, Kosewick J, He X, Kozak M, Wang S (2011) Sensitive measurement of serum 1alpha,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction. Rapid Commun Mass Spectrom 25:1241–1249PubMedCrossRef Yuan C, Kosewick J, He X, Kozak M, Wang S (2011) Sensitive measurement of serum 1alpha,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction. Rapid Commun Mass Spectrom 25:1241–1249PubMedCrossRef
83.
Zurück zum Zitat Strathmann FG, Laha TJ, Hoofnagle AN (2011) Quantification of 1α,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry. Clin Chem 57:1279–1285 Strathmann FG, Laha TJ, Hoofnagle AN (2011) Quantification of 1α,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry. Clin Chem 57:1279–1285
84.
Zurück zum Zitat Turner C, Dalton N, Inaoui R, Fogelman I, Fraser WD, Hampson G (2013) Effect of a 300 000-IU loading dose of ergocalciferol (vitamin D2) on circulating 1,25(OH) 2-vitamin D and Fibroblast Growth Factor-23 (FGF-23) in vitamin D insufficiency. J Clin Endocrinol Metab [Epub ahead of print] Turner C, Dalton N, Inaoui R, Fogelman I, Fraser WD, Hampson G (2013) Effect of a 300 000-IU loading dose of ergocalciferol (vitamin D2) on circulating 1,25(OH) 2-vitamin D and Fibroblast Growth Factor-23 (FGF-23) in vitamin D insufficiency. J Clin Endocrinol Metab [Epub ahead of print]
85.
Zurück zum Zitat Yetley EA, Pfeiffer CM, Schleicher RL, Phinney KW, Lacher DA, Christakos S, Eckfeldt JH, Fleet JC, Howard G, Hoofnagle AN, Hui SL, Lensmeyer GL, Massaro J, Peacock M, Rosner B, Wiebe D, Bailey RL, Coates PM, Looker AC, Sempos C, Johnson CL, Picciano MF (2010) NHANES monitoring of serum 25-hydroxyvitamin D: a roundtable summary. J Nutr 140:2030S–2045SPubMedCrossRef Yetley EA, Pfeiffer CM, Schleicher RL, Phinney KW, Lacher DA, Christakos S, Eckfeldt JH, Fleet JC, Howard G, Hoofnagle AN, Hui SL, Lensmeyer GL, Massaro J, Peacock M, Rosner B, Wiebe D, Bailey RL, Coates PM, Looker AC, Sempos C, Johnson CL, Picciano MF (2010) NHANES monitoring of serum 25-hydroxyvitamin D: a roundtable summary. J Nutr 140:2030S–2045SPubMedCrossRef
Metadaten
Titel
Vitamin D Assays: Past and Present Debates, Difficulties, and Developments
verfasst von
William D. Fraser
Anna M. Milan
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Calcified Tissue International / Ausgabe 2/2013
Print ISSN: 0171-967X
Elektronische ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-012-9693-3

Weitere Artikel der Ausgabe 2/2013

Calcified Tissue International 2/2013 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.