Skip to main content
Erschienen in: Neuroradiology 2/2010

01.02.2010 | Diagnostic Neuroradiology

Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis

verfasst von: Oktay Algin, Bahattin Hakyemez, Mufit Parlak

Erschienen in: Neuroradiology | Ausgabe 2/2010

Einloggen, um Zugang zu erhalten

Abstract

Introduction

In the current study, we aimed to compare the diagnostic efficacies of phase-contrast magnetic resonance imaging (PC-MRI) and three-dimensional constructive interference in steady-state (3D-CISS) sequence over detection of aqueductal stenosis (AS) on the basis of contrast-enhanced magnetic resonance cisternography (MRC).

Methods

Twenty-five patients with clinically and radiologically suspected AS were examined by PC-MRI, 3D-CISS, and MRC. Axial–sagittal PC-MRI and sagittal 3D-CISS were applied to view the cerebral aqueduct. Following injection of 0.5–1 ml intrathecal gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) injection, postcontrast MRC images were obtained in three planes in early and late phases. Aqueductal patency was scored as follows: grade 0, normal; grade 1, partial narrowing; and grade 2, complete obstruction. Results of PC-MRI and 3D-CISS were compared with the findings of MRC.

Results

In PC-MRI, seven cases were assessed as grade 0, 16 cases grade 1, and two cases grade 2. As a result of 3D-CISS sequence, eight cases were evaluated as grade 0, 12 cases grade 1, and five cases grade 2. Based on MRC, nine cases were assessed as grade 0, whereas nine and seven cases were evaluated to be grades 1 and 2, respectively. Five cases that demonstrated partial patency in PC-MRI or 3D-CISS showed complete obstruction by MRC.

Conclusion

PC-MRI is helpful in confirming the AS. However, positive flow does not necessarily exclude the existence of AS. 3D-CISS sequence provides excellent cerebrospinal fluid-to-aqueduct contrast, allowing detailed study of the anatomic features of the aqueduct. MRC should be performed on patients who demonstrate suspected AS findings on PC-MRI and/or 3D-CISS sequences.
Literatur
1.
Zurück zum Zitat Yadav YR, Mukerji G, Parihar V, Sinha M, Pandey S (2009) Complex hydrocephalus (combination of communicating and obstructive type): an important cause of failed endoscopic third ventriculostomy. BMC Res Notes. doi:10.1186/1756-0500/2/137 PubMed Yadav YR, Mukerji G, Parihar V, Sinha M, Pandey S (2009) Complex hydrocephalus (combination of communicating and obstructive type): an important cause of failed endoscopic third ventriculostomy. BMC Res Notes. doi:10.​1186/​1756-0500/​2/​137 PubMed
2.
Zurück zum Zitat Bateman GA (2007) Magnetic resonance imaging quantification of compliance and collateral flow in late-onset idiopathic aqueductal stenosis: venous pathophysiology revisited. J Neurosurg 107:951–958CrossRefPubMed Bateman GA (2007) Magnetic resonance imaging quantification of compliance and collateral flow in late-onset idiopathic aqueductal stenosis: venous pathophysiology revisited. J Neurosurg 107:951–958CrossRefPubMed
3.
Zurück zum Zitat Allan R, Chaseling R, Graf N, Dexter M (2005) Aqueduct stenosis—benign? J Clin Neurosci 12:178–182CrossRefPubMed Allan R, Chaseling R, Graf N, Dexter M (2005) Aqueduct stenosis—benign? J Clin Neurosci 12:178–182CrossRefPubMed
4.
Zurück zum Zitat Tisell M (2005) How should primary aqueductal stenosis in adults be treated?—a review. Acta Neuro Scand 111:143–153 Tisell M (2005) How should primary aqueductal stenosis in adults be treated?—a review. Acta Neuro Scand 111:143–153
5.
Zurück zum Zitat Grossman RI, Yousem DM (2003) Neuroradiology the requisites, 2nd edn. Mosby Elsevier, Philadelphia, pp 372–373 Grossman RI, Yousem DM (2003) Neuroradiology the requisites, 2nd edn. Mosby Elsevier, Philadelphia, pp 372–373
6.
Zurück zum Zitat El Sankari SS, Lehmann P, Gondry-Jouet C, Fichten A, Godefroy O, Meyer ME, Baledent O (2009) Phase-contrast MR imaging support for the diagnosis of aqueductal stenosis. AJNR Am J Neuroradiol 30:209–214CrossRef El Sankari SS, Lehmann P, Gondry-Jouet C, Fichten A, Godefroy O, Meyer ME, Baledent O (2009) Phase-contrast MR imaging support for the diagnosis of aqueductal stenosis. AJNR Am J Neuroradiol 30:209–214CrossRef
7.
Zurück zum Zitat Da Silva LRF, Cavalheiro S (2007) Endoscopic aqueductoplasty in the treatment of aqueductal stenosis. Childs Nerv Syst 23:1263–1268CrossRefPubMed Da Silva LRF, Cavalheiro S (2007) Endoscopic aqueductoplasty in the treatment of aqueductal stenosis. Childs Nerv Syst 23:1263–1268CrossRefPubMed
8.
Zurück zum Zitat Atlas SW, Mark AS, Fram EK (1998) Aqueductal stenosis: evaluation with gradient-echo rapid MR imaging. Radiology 169:449–453 Atlas SW, Mark AS, Fram EK (1998) Aqueductal stenosis: evaluation with gradient-echo rapid MR imaging. Radiology 169:449–453
9.
Zurück zum Zitat Fukuhara T, Luciano MG (2001) Clinical features of late-onset idiopathic aqueductal stenosis. Surg Neurol 55:132–136CrossRefPubMed Fukuhara T, Luciano MG (2001) Clinical features of late-onset idiopathic aqueductal stenosis. Surg Neurol 55:132–136CrossRefPubMed
10.
Zurück zum Zitat Aleman J, Jokura H, Higano S, Akabane A, Shirane R, Yoshimoto T (2001) Value of constructive interference in steady-state, three-dimensional, Fourier transformation magnetic resonance imaging for the neuroendoscopic treatment of hydrocephalus and intracranial cysts. Neurosurgery 48:1291–1295CrossRefPubMed Aleman J, Jokura H, Higano S, Akabane A, Shirane R, Yoshimoto T (2001) Value of constructive interference in steady-state, three-dimensional, Fourier transformation magnetic resonance imaging for the neuroendoscopic treatment of hydrocephalus and intracranial cysts. Neurosurgery 48:1291–1295CrossRefPubMed
11.
Zurück zum Zitat Schroeder HWS, Schweim C, Schweim KH, Gaab MR (2000) Analysis of aqueductal cerebrospinal fluid flow after endoscopic aqueductoplasty by using cine phase-contrast magnetic resonance imaging. Neurosurg Focus 9:1–8CrossRef Schroeder HWS, Schweim C, Schweim KH, Gaab MR (2000) Analysis of aqueductal cerebrospinal fluid flow after endoscopic aqueductoplasty by using cine phase-contrast magnetic resonance imaging. Neurosurg Focus 9:1–8CrossRef
12.
Zurück zum Zitat Schroeder HWS, Oertel J, Gaab MR (2004) Endoscopic aqueductoplasty in the treatment of aqueductal stenosis. Childs Nerv Syst 20:821–827CrossRefPubMed Schroeder HWS, Oertel J, Gaab MR (2004) Endoscopic aqueductoplasty in the treatment of aqueductal stenosis. Childs Nerv Syst 20:821–827CrossRefPubMed
13.
Zurück zum Zitat Doll A, Christmann D, Kerhli P, Abu Eid M, Gillis C, Bogorin A, Thiebaut A, Dietemann JL (2000) Contribution of 3D-CISS MRI for the post therapeutic monitoring of obstructive hydrocephalus. J Neuroradiol 27:218–225PubMed Doll A, Christmann D, Kerhli P, Abu Eid M, Gillis C, Bogorin A, Thiebaut A, Dietemann JL (2000) Contribution of 3D-CISS MRI for the post therapeutic monitoring of obstructive hydrocephalus. J Neuroradiol 27:218–225PubMed
14.
Zurück zum Zitat Joseph VB, Raghuram L, Korah IP, Chacko AG (2003) MR ventriculography for the study of CSF Flow. AJNR Am J Neuroradiol 24:373–381PubMed Joseph VB, Raghuram L, Korah IP, Chacko AG (2003) MR ventriculography for the study of CSF Flow. AJNR Am J Neuroradiol 24:373–381PubMed
15.
Zurück zum Zitat Lee HS, Rao KCVG, Zimmerman RA (1999) Cranial MRI and CT, 4th edn. McGraw-Hill, New York, pp 173–241 Lee HS, Rao KCVG, Zimmerman RA (1999) Cranial MRI and CT, 4th edn. McGraw-Hill, New York, pp 173–241
16.
Zurück zum Zitat Aydin K, Terzibasioglu E, Sencer S, Sencer A, Suoglu Y, Karasu A, Kiris T, Turantan MI (2008) Localization of cerebrospinal fluid leaks by gadolinium-enhanced magnetic resonance cisternography: a 5-year single-center experience. Neurosurgery 62:584–589CrossRefPubMed Aydin K, Terzibasioglu E, Sencer S, Sencer A, Suoglu Y, Karasu A, Kiris T, Turantan MI (2008) Localization of cerebrospinal fluid leaks by gadolinium-enhanced magnetic resonance cisternography: a 5-year single-center experience. Neurosurgery 62:584–589CrossRefPubMed
17.
Zurück zum Zitat Algin O, Hakyemez B, Gokalp KE, Parlak M (2009) Phase-contrast cine MRI versus MR cisternography on the evaluation of the communication between intraventricular arachnoid cysts and neighbouring cerebrospinal fluid spaces. Neuroradiology 51:305–312CrossRefPubMed Algin O, Hakyemez B, Gokalp KE, Parlak M (2009) Phase-contrast cine MRI versus MR cisternography on the evaluation of the communication between intraventricular arachnoid cysts and neighbouring cerebrospinal fluid spaces. Neuroradiology 51:305–312CrossRefPubMed
18.
Zurück zum Zitat Nilsson S, Ortoft K, Mölstad S (2008) The accuracy of general practitioners' clinical assessment of chest pain patients. Eur J Gen Pract 14:50–55CrossRefPubMed Nilsson S, Ortoft K, Mölstad S (2008) The accuracy of general practitioners' clinical assessment of chest pain patients. Eur J Gen Pract 14:50–55CrossRefPubMed
19.
Zurück zum Zitat Kehler U, Regelsberger J, Gliemroth J, Westphal M (2006) Outcome prediction of third ventriculostomy: a proposed hydrocephalus grading system. Minim Invasive Neurosurg 49:238–243CrossRefPubMed Kehler U, Regelsberger J, Gliemroth J, Westphal M (2006) Outcome prediction of third ventriculostomy: a proposed hydrocephalus grading system. Minim Invasive Neurosurg 49:238–243CrossRefPubMed
20.
Zurück zum Zitat Kadowaki C, Hara M, Numoto M, Takeuchi K, Saito I (1995) Cine magnetic resonance imaging of aqueductal stenosis. Childs Nerv Syst 11:107–111CrossRefPubMed Kadowaki C, Hara M, Numoto M, Takeuchi K, Saito I (1995) Cine magnetic resonance imaging of aqueductal stenosis. Childs Nerv Syst 11:107–111CrossRefPubMed
21.
Zurück zum Zitat Drayer BP, Rosenbaum AE, Higman HB (1977) Cerebrospinal fluid imaging using serial metrizamide CT cisternography. Neuroradiology 28:7–17CrossRef Drayer BP, Rosenbaum AE, Higman HB (1977) Cerebrospinal fluid imaging using serial metrizamide CT cisternography. Neuroradiology 28:7–17CrossRef
22.
Zurück zum Zitat Takahashi M, Arii H, Tamakawa Y (1978) Comparison of metrizamide CT cisternography with radionuclide cisternography in abnormal cerebrospinal fluid dynamics. Neuroradiology 16:199–202CrossRefPubMed Takahashi M, Arii H, Tamakawa Y (1978) Comparison of metrizamide CT cisternography with radionuclide cisternography in abnormal cerebrospinal fluid dynamics. Neuroradiology 16:199–202CrossRefPubMed
Metadaten
Titel
Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis
verfasst von
Oktay Algin
Bahattin Hakyemez
Mufit Parlak
Publikationsdatum
01.02.2010
Verlag
Springer-Verlag
Erschienen in
Neuroradiology / Ausgabe 2/2010
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-009-0592-x

Weitere Artikel der Ausgabe 2/2010

Neuroradiology 2/2010 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.