Skip to main content
Erschienen in: Neuroradiology 4/2013

01.04.2013 | Diagnostic Neuroradiology

High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose

verfasst von: A. Korn, M. Fenchel, B. Bender, S. Danz, C. Thomas, D. Ketelsen, C. D. Claussen, G. Moonis, B. Krauss, M. Heuschmid, U. Ernemann, H. Brodoefel

Erschienen in: Neuroradiology | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Introduction

High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck.

Methods

CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols.

Results

Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35 % (218.2 ± 30 versus 141.8 ± 20 mGy × cm).

Conclusions

Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.
Literatur
1.
Zurück zum Zitat Rothwell PM, Coull AJ, Silver LE et al (2005) Population-based study of event-rate, incidence, case fatality, and mortality for all acute vascular events in all arterial territories (Oxford Vascular Study). Lancet 366(9499):1773–1783PubMedCrossRef Rothwell PM, Coull AJ, Silver LE et al (2005) Population-based study of event-rate, incidence, case fatality, and mortality for all acute vascular events in all arterial territories (Oxford Vascular Study). Lancet 366(9499):1773–1783PubMedCrossRef
2.
Zurück zum Zitat Bamford J, Sandercock P, Dennis M, Burn J, Warlow C (1991) Classification and natural history of clinically identifiable subtypes of cerebral infarction. Lancet 337(8756):1521–1526PubMedCrossRef Bamford J, Sandercock P, Dennis M, Burn J, Warlow C (1991) Classification and natural history of clinically identifiable subtypes of cerebral infarction. Lancet 337(8756):1521–1526PubMedCrossRef
3.
Zurück zum Zitat (1998) Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet 351(9113): 1379–1387 (1998) Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet 351(9113): 1379–1387
4.
Zurück zum Zitat Piotin M, Spelle L, Martin JB et al (2000) Percutaneous transluminal angioplasty and stenting of the proximal vertebral artery for symptomatic stenosis. AJNR Am J Neuroradiol 21(4):727–731PubMed Piotin M, Spelle L, Martin JB et al (2000) Percutaneous transluminal angioplasty and stenting of the proximal vertebral artery for symptomatic stenosis. AJNR Am J Neuroradiol 21(4):727–731PubMed
5.
Zurück zum Zitat Qureshi AI, Suri MF, Ali Z et al (2001) Role of conventional angiography in evaluation of patients with carotid artery stenosis demonstrated by Doppler ultrasound in general practice. Stroke 32(10):2287–2291PubMedCrossRef Qureshi AI, Suri MF, Ali Z et al (2001) Role of conventional angiography in evaluation of patients with carotid artery stenosis demonstrated by Doppler ultrasound in general practice. Stroke 32(10):2287–2291PubMedCrossRef
6.
Zurück zum Zitat Lohan DG, Barkhordarian F, Saleh R et al (2007) MR angiography at 3 T for assessment of the external carotid artery system. AJR Am J Roentgenol 189(5):1088–1094PubMedCrossRef Lohan DG, Barkhordarian F, Saleh R et al (2007) MR angiography at 3 T for assessment of the external carotid artery system. AJR Am J Roentgenol 189(5):1088–1094PubMedCrossRef
7.
Zurück zum Zitat Bartlett ES, Walters TD, Symons SP, Fox AJ (2007) Carotid stenosis index revisited with direct CT angiography measurement of carotid arteries to quantify carotid stenosis. Stroke 38(2):286–291PubMedCrossRef Bartlett ES, Walters TD, Symons SP, Fox AJ (2007) Carotid stenosis index revisited with direct CT angiography measurement of carotid arteries to quantify carotid stenosis. Stroke 38(2):286–291PubMedCrossRef
8.
Zurück zum Zitat Wolpert SM, Caplan LR (1992) Current role of cerebral angiography in the diagnosis of cerebrovascular diseases. AJR Am J Roentgenol 159(1):191–197PubMedCrossRef Wolpert SM, Caplan LR (1992) Current role of cerebral angiography in the diagnosis of cerebrovascular diseases. AJR Am J Roentgenol 159(1):191–197PubMedCrossRef
9.
Zurück zum Zitat Kim JJ, Dillon WP, Glastonbury CM, Provenzale JM, Wintermark M (2010) Sixty-four-section multidetector CT angiography of carotid arteries: a systematic analysis of image quality and artifacts. AJNR Am J Neuroradiol 31(1):91–99PubMedCrossRef Kim JJ, Dillon WP, Glastonbury CM, Provenzale JM, Wintermark M (2010) Sixty-four-section multidetector CT angiography of carotid arteries: a systematic analysis of image quality and artifacts. AJNR Am J Neuroradiol 31(1):91–99PubMedCrossRef
10.
Zurück zum Zitat Alkadhi H, Stolzmann P, Desbiolles L et al (2010) Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart 96(12):933–938PubMedCrossRef Alkadhi H, Stolzmann P, Desbiolles L et al (2010) Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart 96(12):933–938PubMedCrossRef
11.
Zurück zum Zitat Beeres M, Schell B, Mastragelopoulos A et al (2012) High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience. Eur Radiol 22(1):129–137PubMedCrossRef Beeres M, Schell B, Mastragelopoulos A et al (2012) High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience. Eur Radiol 22(1):129–137PubMedCrossRef
12.
Zurück zum Zitat De Zordo T, von Lutterotti K, Dejaco C et al (2012) Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT. Eur Radiol 22(2):279–286PubMedCrossRef De Zordo T, von Lutterotti K, Dejaco C et al (2012) Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT. Eur Radiol 22(2):279–286PubMedCrossRef
13.
Zurück zum Zitat Mnyusiwalla A, Aviv RI, Symons SP (2009) Radiation dose from multidetector row CT imaging for acute stroke. Neuroradiology 51(10):635–640PubMedCrossRef Mnyusiwalla A, Aviv RI, Symons SP (2009) Radiation dose from multidetector row CT imaging for acute stroke. Neuroradiology 51(10):635–640PubMedCrossRef
14.
Zurück zum Zitat Wardlaw JM, Chappell FM, Best JJ, Wartolowska K, Berry E (2006) Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 367(9521):1503–1512PubMedCrossRef Wardlaw JM, Chappell FM, Best JJ, Wartolowska K, Berry E (2006) Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 367(9521):1503–1512PubMedCrossRef
15.
Zurück zum Zitat Sommer WH, Albrecht E, Bamberg F et al (2010) Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. AJR Am J Roentgenol 195(6):1306–1312PubMedCrossRef Sommer WH, Albrecht E, Bamberg F et al (2010) Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. AJR Am J Roentgenol 195(6):1306–1312PubMedCrossRef
16.
Zurück zum Zitat Gulli G, Khan S, Markus HS (2009) Vertebrobasilar stenosis predicts high early recurrent stroke risk in posterior circulation stroke and TIA. Stroke 40(8):2732–2737PubMedCrossRef Gulli G, Khan S, Markus HS (2009) Vertebrobasilar stenosis predicts high early recurrent stroke risk in posterior circulation stroke and TIA. Stroke 40(8):2732–2737PubMedCrossRef
17.
Zurück zum Zitat Marquardt L, Kuker W, Chandratheva A, Geraghty O, Rothwell PM (2009) Incidence and prognosis of > or = 50 % symptomatic vertebral or basilar artery stenosis: prospective population-based study. Brain 132(Pt 4):982–988PubMed Marquardt L, Kuker W, Chandratheva A, Geraghty O, Rothwell PM (2009) Incidence and prognosis of > or = 50 % symptomatic vertebral or basilar artery stenosis: prospective population-based study. Brain 132(Pt 4):982–988PubMed
18.
Zurück zum Zitat Wityk RJ, Chang HM, Rosengart A et al (1998) Proximal extracranial vertebral artery disease in the New England Medical Center Posterior Circulation Registry. Arch Neurol 55(4):470–478PubMedCrossRef Wityk RJ, Chang HM, Rosengart A et al (1998) Proximal extracranial vertebral artery disease in the New England Medical Center Posterior Circulation Registry. Arch Neurol 55(4):470–478PubMedCrossRef
19.
Zurück zum Zitat Flossmann E, Rothwell PM (2003) Prognosis of vertebrobasilar transient ischaemic attack and minor stroke. Brain 126(Pt 9):1940–1954PubMedCrossRef Flossmann E, Rothwell PM (2003) Prognosis of vertebrobasilar transient ischaemic attack and minor stroke. Brain 126(Pt 9):1940–1954PubMedCrossRef
20.
Zurück zum Zitat Cloud GC, Crawley F, Clifton A, McCabe DJ, Brown MM, Markus HS (2003) Vertebral artery origin angioplasty and primary stenting: safety and restenosis rates in a prospective series. J Neurol Neurosurg Psychiatry 74(5):586–590PubMedCrossRef Cloud GC, Crawley F, Clifton A, McCabe DJ, Brown MM, Markus HS (2003) Vertebral artery origin angioplasty and primary stenting: safety and restenosis rates in a prospective series. J Neurol Neurosurg Psychiatry 74(5):586–590PubMedCrossRef
21.
Zurück zum Zitat Compter A, van der Worp HB, Schonewille WJ et al (2008) VAST: Vertebral Artery Stenting Trial. Protocol for a randomised safety and feasibility trial. Trials 9:65PubMedCrossRef Compter A, van der Worp HB, Schonewille WJ et al (2008) VAST: Vertebral Artery Stenting Trial. Protocol for a randomised safety and feasibility trial. Trials 9:65PubMedCrossRef
22.
Zurück zum Zitat Khan S, Cloud GC, Kerry S, Markus HS (2007) Imaging of vertebral artery stenosis: a systematic review. J Neurol Neurosurg Psychiatry 78(11):1218–1225PubMedCrossRef Khan S, Cloud GC, Kerry S, Markus HS (2007) Imaging of vertebral artery stenosis: a systematic review. J Neurol Neurosurg Psychiatry 78(11):1218–1225PubMedCrossRef
23.
Zurück zum Zitat Jumaa M, Popescu A, Tsay J et al (2012) Evaluation of vertebral artery origin stenosis: a retrospective comparison of three techniques. J Neuroimaging 22(1):14–16PubMedCrossRef Jumaa M, Popescu A, Tsay J et al (2012) Evaluation of vertebral artery origin stenosis: a retrospective comparison of three techniques. J Neuroimaging 22(1):14–16PubMedCrossRef
24.
Zurück zum Zitat Karlo C, Leschka S, Goetti RP et al (2011) High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG synchronization. Eur Radiol 21(1):205–212PubMedCrossRef Karlo C, Leschka S, Goetti RP et al (2011) High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG synchronization. Eur Radiol 21(1):205–212PubMedCrossRef
25.
Zurück zum Zitat Hinkmann FM, Voit HL, Anders K et al (2009) Ultra-fast carotid CT-angiography: low versus standard volume contrast material protocol for a 128-slice CT-system. Invest Radiol 44(5):257–264PubMedCrossRef Hinkmann FM, Voit HL, Anders K et al (2009) Ultra-fast carotid CT-angiography: low versus standard volume contrast material protocol for a 128-slice CT-system. Invest Radiol 44(5):257–264PubMedCrossRef
Metadaten
Titel
High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
verfasst von
A. Korn
M. Fenchel
B. Bender
S. Danz
C. Thomas
D. Ketelsen
C. D. Claussen
G. Moonis
B. Krauss
M. Heuschmid
U. Ernemann
H. Brodoefel
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
Neuroradiology / Ausgabe 4/2013
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-012-1120-y

Weitere Artikel der Ausgabe 4/2013

Neuroradiology 4/2013 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.