Skip to main content
Erschienen in: Neuroradiology 2/2016

01.02.2016 | Interventional Neuroradiology

Delayed hemorrhagic complications after flow diversion for intracranial aneurysms: a literature overview

verfasst von: Aymeric Rouchaud, Waleed Brinjikji, Giuseppe Lanzino, Harry J. Cloft, Ramanathan Kadirvel, David F. Kallmes

Erschienen in: Neuroradiology | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Delayed aneurysm rupture and delayed intraparenchymal hemorrhages (DIPH) are poorly understood and often fatal complications of flow diversion (FD) for intracranial aneurysms. The purpose of this study was to identify risk factors for these complications.

Methods

We performed a systematic review on post-FD delayed aneurysm rupture and DIPH. For each reported case, we collected the following information: aneurysm location, size and rupture status, type of flow diverter used, timing of the hemorrhage, and neurological outcome. We reported descriptive statistics of patients suffering DIPH and delayed aneurysm rupture to determine if there were any characteristics consistently present among patients with these complications.

Results

We identified 81 delayed aneurysm ruptures and 101 DIPH. Of the delayed ruptures, 76.6 % (45/58) occurred within 1 month. The prognosis of delayed ruptures was poor, with 81.3 % (61/75) experiencing death or poor neurological outcome. Giant aneurysms accounted for 46.3 % of ruptures (31/67). Of these aneurysms, 80.9 % (55/68) were initially unruptured. Of the delayed ruptured aneurysms, 17.8 % (13/73) had prior or concomitant coiling. DIPHs were ipsilateral to the treated aneurysm in 82.2 % (60/73) of cases. Of the DIPH, 86.0 % (43/50) occurred within 1 month after FDS. Combined morbidity/mortality rate was 68.5 % (50/73) following DIPH. Of DIPHs, 23.0 % (14/61) occurred in patients with giant aneurysms.

Conclusions

Our study demonstrates that giant aneurysms represent almost 50 % of delayed aneurysm ruptures in the flow diverter literature. About 20 % of delayed ruptures occurred despite associated coiling. A substantial proportion of DIPHs occur early following FDS treatment of giant aneurysms.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D (2009) Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience. Neurosurgery 64(4):632–642. doi:10.1227/01.NEU.0000339109.98070.65, discussion 642-633; quiz N636 CrossRefPubMed Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D (2009) Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience. Neurosurgery 64(4):632–642. doi:10.​1227/​01.​NEU.​0000339109.​98070.​65, discussion 642-633; quiz N636 CrossRefPubMed
2.
Zurück zum Zitat Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, Leclerc X (2010) Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41(10):2247–2253. doi:10.1161/STROKEAHA.110.589911 CrossRefPubMed Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, Leclerc X (2010) Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41(10):2247–2253. doi:10.​1161/​STROKEAHA.​110.​589911 CrossRefPubMed
3.
Zurück zum Zitat Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK (2013) Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 267(3):858–868. doi:10.1148/radiol.13120099 CrossRefPubMed Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK (2013) Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 267(3):858–868. doi:10.​1148/​radiol.​13120099 CrossRefPubMed
6.
Zurück zum Zitat Klisch J, Turk A, Turner R, Woo HH, Fiorella D (2011) Very late thrombosis of flow-diverting constructs after the treatment of large fusiform posterior circulation aneurysms. AJNR Am J Neuroradiol 32(4):627–632. doi:10.3174/ajnr.A2571 CrossRefPubMed Klisch J, Turk A, Turner R, Woo HH, Fiorella D (2011) Very late thrombosis of flow-diverting constructs after the treatment of large fusiform posterior circulation aneurysms. AJNR Am J Neuroradiol 32(4):627–632. doi:10.​3174/​ajnr.​A2571 CrossRefPubMed
7.
8.
Zurück zum Zitat Cirillo L, Leonardi M, Dall’olio M, Princiotta C, Stafa A, Simonetti L, Toni F, Agati R (2012) Complications in the treatment of intracranial aneurysms with silk stents: an analysis of 30 consecutive patients. Interv Neuroradiol 18(4):413–425PubMedPubMedCentral Cirillo L, Leonardi M, Dall’olio M, Princiotta C, Stafa A, Simonetti L, Toni F, Agati R (2012) Complications in the treatment of intracranial aneurysms with silk stents: an analysis of 30 consecutive patients. Interv Neuroradiol 18(4):413–425PubMedPubMedCentral
9.
Zurück zum Zitat Phillips TJ, Wenderoth JD, Phatouros CC, Rice H, Singh TP, Devilliers L, Wycoco V, Meckel S, McAuliffe W (2012) Safety of the pipeline embolization device in treatment of posterior circulation aneurysms. AJNR Am J Neuroradiol 33(7):1225–1231. doi:10.3174/ajnr.A3166 CrossRefPubMed Phillips TJ, Wenderoth JD, Phatouros CC, Rice H, Singh TP, Devilliers L, Wycoco V, Meckel S, McAuliffe W (2012) Safety of the pipeline embolization device in treatment of posterior circulation aneurysms. AJNR Am J Neuroradiol 33(7):1225–1231. doi:10.​3174/​ajnr.​A3166 CrossRefPubMed
10.
Zurück zum Zitat Turowski B, Macht S, Kulcsar Z, Hanggi D, Stummer W (2011) Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 53(1):37–41. doi:10.1007/s00234-010-0676-7 CrossRefPubMed Turowski B, Macht S, Kulcsar Z, Hanggi D, Stummer W (2011) Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 53(1):37–41. doi:10.​1007/​s00234-010-0676-7 CrossRefPubMed
11.
Zurück zum Zitat Cebral JR, Mut F, Raschi M, Scrivano E, Ceratto R, Lylyk P, Putman CM (2011) Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 32(1):27–33. doi:10.3174/ajnr.A2398 PubMed Cebral JR, Mut F, Raschi M, Scrivano E, Ceratto R, Lylyk P, Putman CM (2011) Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 32(1):27–33. doi:10.​3174/​ajnr.​A2398 PubMed
12.
Zurück zum Zitat Kulcsár Z SI (2012) The ESMINT retrospective analysis of delayed aneurysm ruptures after flow diversion (RADAR) study. The eJournal of the European Society of Minimally Invasive Neurological Therapy Kulcsár Z SI (2012) The ESMINT retrospective analysis of delayed aneurysm ruptures after flow diversion (RADAR) study. The eJournal of the European Society of Minimally Invasive Neurological Therapy
13.
Zurück zum Zitat Kulcsar Z, Houdart E, Bonafe A, Parker G, Millar J, Goddard AJ, Renowden S, Gal G, Turowski B, Mitchell K, Gray F, Rodriguez M, van den Berg R, Gruber A, Desal H, Wanke I, Rufenacht DA (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32(1):20–25. doi:10.3174/ajnr.A2370 PubMed Kulcsar Z, Houdart E, Bonafe A, Parker G, Millar J, Goddard AJ, Renowden S, Gal G, Turowski B, Mitchell K, Gray F, Rodriguez M, van den Berg R, Gruber A, Desal H, Wanke I, Rufenacht DA (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32(1):20–25. doi:10.​3174/​ajnr.​A2370 PubMed
14.
Zurück zum Zitat Cruz JP, Chow M, O’Kelly C, Marotta B, Spears J, Montanera W, Fiorella D, Marotta T (2012) Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms. AJNR Am J Neuroradiol 33(4):603–608. doi:10.3174/ajnr.A3065 CrossRefPubMed Cruz JP, Chow M, O’Kelly C, Marotta B, Spears J, Montanera W, Fiorella D, Marotta T (2012) Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms. AJNR Am J Neuroradiol 33(4):603–608. doi:10.​3174/​ajnr.​A3065 CrossRefPubMed
15.
Zurück zum Zitat Saatci I, Yavuz K, Ozer C, Geyik S, Cekirge HS (2012) Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 33(8):1436–1446. doi:10.3174/ajnr.A3246 CrossRefPubMed Saatci I, Yavuz K, Ozer C, Geyik S, Cekirge HS (2012) Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 33(8):1436–1446. doi:10.​3174/​ajnr.​A3246 CrossRefPubMed
16.
Zurück zum Zitat Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J, Kadziolka K, Barreau X, Dousset V, Bonafe A (2012) Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol 33(6):1150–1155. doi:10.3174/ajnr.A2907 CrossRefPubMed Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J, Kadziolka K, Barreau X, Dousset V, Bonafe A (2012) Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol 33(6):1150–1155. doi:10.​3174/​ajnr.​A2907 CrossRefPubMed
17.
Zurück zum Zitat Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol 36(1):108–115. doi:10.3174/ajnr.A4111 CrossRefPubMed Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol 36(1):108–115. doi:10.​3174/​ajnr.​A4111 CrossRefPubMed
18.
Zurück zum Zitat Adolph R, Vorp DA, Steed DL, Webster MW, Kameneva MV, Watkins SC (1997) Cellular content and permeability of intraluminal thrombus in abdominal aortic aneurysm. J Vasc Surg 25(5):916–926CrossRefPubMed Adolph R, Vorp DA, Steed DL, Webster MW, Kameneva MV, Watkins SC (1997) Cellular content and permeability of intraluminal thrombus in abdominal aortic aneurysm. J Vasc Surg 25(5):916–926CrossRefPubMed
19.
Zurück zum Zitat Rossignol P, Fontaine V, Meilhac O, Angles-Cano E, Jacob MP, Michel JB (2002) Physiopathology of aortic aneurysm. Rev Prat 52(10):1061–1065PubMed Rossignol P, Fontaine V, Meilhac O, Angles-Cano E, Jacob MP, Michel JB (2002) Physiopathology of aortic aneurysm. Rev Prat 52(10):1061–1065PubMed
20.
Zurück zum Zitat Carrell TW, Burnand KG, Booth NA, Humphries J, Smith A (2006) Intraluminal thrombus enhances proteolysis in abdominal aortic aneurysms. Vascular 14(1):9–16CrossRefPubMed Carrell TW, Burnand KG, Booth NA, Humphries J, Smith A (2006) Intraluminal thrombus enhances proteolysis in abdominal aortic aneurysms. Vascular 14(1):9–16CrossRefPubMed
22.
Zurück zum Zitat Houard X, Rouzet F, Touat Z, Philippe M, Dominguez M, Fontaine V, Sarda-Mantel L, Meulemans A, Le Guludec D, Meilhac O, Michel JB (2007) Topology of the fibrinolytic system within the mural thrombus of human abdominal aortic aneurysms. J Pathol 212(1):20–28. doi:10.1002/path.2148 CrossRefPubMed Houard X, Rouzet F, Touat Z, Philippe M, Dominguez M, Fontaine V, Sarda-Mantel L, Meulemans A, Le Guludec D, Meilhac O, Michel JB (2007) Topology of the fibrinolytic system within the mural thrombus of human abdominal aortic aneurysms. J Pathol 212(1):20–28. doi:10.​1002/​path.​2148 CrossRefPubMed
24.
Zurück zum Zitat Frosen J, Piippo A, Paetau A, Kangasniemi M, Niemela M, Hernesniemi J, Jaaskelainen J (2004) Remodeling of saccular cerebral artery aneurysm wall is associated with rupture: histological analysis of 24 unruptured and 42 ruptured cases. Stroke 35(10):2287–2293. doi:10.1161/01.STR.0000140636.30204.da CrossRefPubMed Frosen J, Piippo A, Paetau A, Kangasniemi M, Niemela M, Hernesniemi J, Jaaskelainen J (2004) Remodeling of saccular cerebral artery aneurysm wall is associated with rupture: histological analysis of 24 unruptured and 42 ruptured cases. Stroke 35(10):2287–2293. doi:10.​1161/​01.​STR.​0000140636.​30204.​da CrossRefPubMed
26.
27.
Zurück zum Zitat Diener HC, Bogousslavsky J, Brass LM, Cimminiello C, Csiba L, Kaste M, Leys D, Matias-Guiu J, Rupprecht HJ, MATCH investigators (2004) Aspirin and clopidogrel compared with clopidogrel alone after recent ischaemic stroke or transient ischaemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial. Lancet 364(9431):331–337. doi:10.1016/S0140-6736(04)16721-4 CrossRefPubMed Diener HC, Bogousslavsky J, Brass LM, Cimminiello C, Csiba L, Kaste M, Leys D, Matias-Guiu J, Rupprecht HJ, MATCH investigators (2004) Aspirin and clopidogrel compared with clopidogrel alone after recent ischaemic stroke or transient ischaemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial. Lancet 364(9431):331–337. doi:10.​1016/​S0140-6736(04)16721-4 CrossRefPubMed
28.
Zurück zum Zitat Shapiro M, Becske T, Sahlein D, Babb J, Nelson PK (2012) Stent-supported aneurysm coiling: a literature survey of treatment and follow-up. AJNR Am J Neuroradiol 33(1):159–163. doi:10.3174/ajnr.A2719 CrossRefPubMed Shapiro M, Becske T, Sahlein D, Babb J, Nelson PK (2012) Stent-supported aneurysm coiling: a literature survey of treatment and follow-up. AJNR Am J Neuroradiol 33(1):159–163. doi:10.​3174/​ajnr.​A2719 CrossRefPubMed
29.
Zurück zum Zitat Velat GJ, Fargen KM, Lawson MF, Hoh BL, Fiorella D, Mocco J (2012) Delayed intraparenchymal hemorrhage following pipeline embolization device treatment for a giant recanalized ophthalmic aneurysm. J NeuroInterv Surg 4(5), e24. doi:10.1136/neurintsurg-2011-010129 CrossRefPubMed Velat GJ, Fargen KM, Lawson MF, Hoh BL, Fiorella D, Mocco J (2012) Delayed intraparenchymal hemorrhage following pipeline embolization device treatment for a giant recanalized ophthalmic aneurysm. J NeuroInterv Surg 4(5), e24. doi:10.​1136/​neurintsurg-2011-010129 CrossRefPubMed
30.
Zurück zum Zitat Mitha AP, Mynard JP, Storwick JA, Shivji ZI, Wong JH, Morrish W (2015) Can the Windkessel hypothesis explain delayed intraparenchymal haemorrhage after flow diversion? A case report and model-based analysis of possible mechanisms. Heart Lung Circ. doi:10.1016/j.hlc.2015.02.001 PubMed Mitha AP, Mynard JP, Storwick JA, Shivji ZI, Wong JH, Morrish W (2015) Can the Windkessel hypothesis explain delayed intraparenchymal haemorrhage after flow diversion? A case report and model-based analysis of possible mechanisms. Heart Lung Circ. doi:10.​1016/​j.​hlc.​2015.​02.​001 PubMed
31.
Zurück zum Zitat Iosif C, Camilleri Y, Saleme S, Caire F, Yardin C, Ponomarjova S, Boncoeur-Martel MP, Mounayer C (2015) Diffusion-weighted imaging-detected ischemic lesions associated with flow-diverting stents in intracranial aneurysms: safety, potential mechanisms, clinical outcome, and concerns. J Neurosurg 122(3):627–636. doi:10.3171/2014.10.JNS132566 CrossRefPubMed Iosif C, Camilleri Y, Saleme S, Caire F, Yardin C, Ponomarjova S, Boncoeur-Martel MP, Mounayer C (2015) Diffusion-weighted imaging-detected ischemic lesions associated with flow-diverting stents in intracranial aneurysms: safety, potential mechanisms, clinical outcome, and concerns. J Neurosurg 122(3):627–636. doi:10.​3171/​2014.​10.​JNS132566 CrossRefPubMed
32.
Zurück zum Zitat Tomas C, Benaissa A, Herbreteau D, Kadziolka K, Pierot L (2014) Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter. Neuroradiology 56(2):155–161. doi:10.1007/s00234-013-1302-2 CrossRefPubMed Tomas C, Benaissa A, Herbreteau D, Kadziolka K, Pierot L (2014) Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter. Neuroradiology 56(2):155–161. doi:10.​1007/​s00234-013-1302-2 CrossRefPubMed
33.
Zurück zum Zitat Hu YC, Deshmukh VR, Albuquerque FC, Fiorella D, Nixon RR, Heck DV, Barnwell SL, McDougall CG (2014) Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device. J Neurosurg 120(2):365–374. doi:10.3171/2013.11.JNS131599 CrossRefPubMed Hu YC, Deshmukh VR, Albuquerque FC, Fiorella D, Nixon RR, Heck DV, Barnwell SL, McDougall CG (2014) Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device. J Neurosurg 120(2):365–374. doi:10.​3171/​2013.​11.​JNS131599 CrossRefPubMed
Metadaten
Titel
Delayed hemorrhagic complications after flow diversion for intracranial aneurysms: a literature overview
verfasst von
Aymeric Rouchaud
Waleed Brinjikji
Giuseppe Lanzino
Harry J. Cloft
Ramanathan Kadirvel
David F. Kallmes
Publikationsdatum
01.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 2/2016
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-015-1615-4

Weitere Artikel der Ausgabe 2/2016

Neuroradiology 2/2016 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Neu im Fachgebiet Neurologie

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.