Abstract

Background

Diffusion imaging has proved to be a powerful tool for diagnosing ischemic lesions in the brain, and the technique is now being applied to other organs, including the kidneys. For quantitative studies it is important to define the normal values of the apparent diffusion coefficient (ADC), given the important physiological changes that occur in the kidney during early childhood it is likely that the ADC changes markedly during this period.

Objective

To evaluate the age dependent changes in the ADC of normal kidneys in the pediatric population.

Materals and methods

The whole kidney ADC was calculated for 62 pediatric patients on a 1.5-T system using a respiratory-triggered, single-shot diffusion tensor imaging sequence with b values of 50, 200, and 350 mm2/s.

Results

The ADC was found to increase with age with the largest increase being in the first year of life, the rate of change being described by a constant plus a power function, specifically 1349+{358.5*{age^0.34}}, (P<0.001).

Conclusion

The renal ADC changes significantly during childhood.
Literatur
1.
Zurück zum Zitat Muller MF, Prasad PV, Bimmler D, et al (1994) Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology 193:711–715PubMed Muller MF, Prasad PV, Bimmler D, et al (1994) Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology 193:711–715PubMed
2.
Zurück zum Zitat Namimoto MF, Yamashita Y, Mitsuzaki K, et al (1999) Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion weighted echo-planar imaging. J Magn Reson Imaging 9:832–837CrossRefPubMed Namimoto MF, Yamashita Y, Mitsuzaki K, et al (1999) Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion weighted echo-planar imaging. J Magn Reson Imaging 9:832–837CrossRefPubMed
3.
Zurück zum Zitat Ries M, Jones RA, Basseau F, et al (2001) Diffusion tensor MRI of the human kidney. J Magn Reson Imaging 14:42–49CrossRefPubMed Ries M, Jones RA, Basseau F, et al (2001) Diffusion tensor MRI of the human kidney. J Magn Reson Imaging 14:42–49CrossRefPubMed
4.
Zurück zum Zitat Le Bihan D, Breton E, Lallemand D, et al (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168:497–505PubMed Le Bihan D, Breton E, Lallemand D, et al (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168:497–505PubMed
5.
Zurück zum Zitat Duong TQ, Kim SG (2000) In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain. Magn Reson Med 43:393–402PubMed Duong TQ, Kim SG (2000) In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain. Magn Reson Med 43:393–402PubMed
6.
Zurück zum Zitat Murtz P, Flacke S, Traber F, et al (2002) Abdomen: diffusion weighted MR imaging with pulse triggered single shot sequences. Radiology 224:258–264PubMed Murtz P, Flacke S, Traber F, et al (2002) Abdomen: diffusion weighted MR imaging with pulse triggered single shot sequences. Radiology 224:258–264PubMed
7.
Zurück zum Zitat Van Gelderen P, De Vleeschouwer MHM, DesPres D, et al (1994) Water diffusion and acute stroke. Magn Reson Med 31:154–163PubMed Van Gelderen P, De Vleeschouwer MHM, DesPres D, et al (1994) Water diffusion and acute stroke. Magn Reson Med 31:154–163PubMed
8.
Zurück zum Zitat Wong EC, Cox RW, Song AW (1995) Optimised isotropic diffusion weighting. Magn Reson Med 34:139–143PubMed Wong EC, Cox RW, Song AW (1995) Optimised isotropic diffusion weighting. Magn Reson Med 34:139–143PubMed
9.
Zurück zum Zitat Toyoshima S, Noguchi K, Seto H, et al (2000) Functional evaluation of hydronephrosis by diffusion-weighted MR imaging. Relationship between apparent diffusion coefficient and split glomerular filtration rate. Acta Radiol 41:642–646CrossRefPubMed Toyoshima S, Noguchi K, Seto H, et al (2000) Functional evaluation of hydronephrosis by diffusion-weighted MR imaging. Relationship between apparent diffusion coefficient and split glomerular filtration rate. Acta Radiol 41:642–646CrossRefPubMed
10.
Zurück zum Zitat Anand SK (1991) Maturation of renal function. In: Taeusch HW, Ballard RA, Avery ME (eds) Diseases of the newborn, 6th edn. Saunders, Philadelphia, pp 837–855 Anand SK (1991) Maturation of renal function. In: Taeusch HW, Ballard RA, Avery ME (eds) Diseases of the newborn, 6th edn. Saunders, Philadelphia, pp 837–855
11.
Zurück zum Zitat Peters AM, Henderson BL, Lui D (2000) Indexed glomerular filtration rate as a function of age and body size. Clin Sci 98:439–444PubMed Peters AM, Henderson BL, Lui D (2000) Indexed glomerular filtration rate as a function of age and body size. Clin Sci 98:439–444PubMed
12.
Zurück zum Zitat Melham ER, Itoh R, Jones L, et al (2000) Diffusion tensor MR imaging of the brain: effect of diffusion weighting on trace and anisotropy measurements. Am J Neuroradiol 21:1813–1820PubMed Melham ER, Itoh R, Jones L, et al (2000) Diffusion tensor MR imaging of the brain: effect of diffusion weighting on trace and anisotropy measurements. Am J Neuroradiol 21:1813–1820PubMed
13.
Zurück zum Zitat Nusbaum AO, Tang CY, Wei T, et al (2000) Whole-brain diffusion MR histograms differ between MS subtypes. Neurology 54:1421–1427 Nusbaum AO, Tang CY, Wei T, et al (2000) Whole-brain diffusion MR histograms differ between MS subtypes. Neurology 54:1421–1427
14.
Zurück zum Zitat Le Bihan (ed) (1995) Diffusion and perfusion magnetic resonance imaging: applications to functional MRI. Raven Press, New York Le Bihan (ed) (1995) Diffusion and perfusion magnetic resonance imaging: applications to functional MRI. Raven Press, New York
15.
Zurück zum Zitat Pinnock C, Lin T, Smith T (2002) Fundamentals of anaesthesia. Greenwich Medical Media, London Pinnock C, Lin T, Smith T (2002) Fundamentals of anaesthesia. Greenwich Medical Media, London
Metadaten
Titel
Age dependence of the renal apparent diffusion coefficient in children
verfasst von
Richard A. Jones
J. Damien Grattan-Smith
Publikationsdatum
01.12.2003
Verlag
Springer-Verlag
Erschienen in
Pediatric Radiology / Ausgabe 12/2003
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-003-0982-x

Weitere Artikel der Ausgabe 12/2003

Pediatric Radiology 12/2003 Zur Ausgabe

Letter to the Editor

Reply

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.