Skip to main content
Erschienen in: Pediatric Radiology 12/2006

01.12.2006 | Original Article

Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease

verfasst von: Michael Fenchel, Gerald F. Greil, Petros Martirosian, Ulrich Kramer, Fritz Schick, Claus D. Claussen, Ludger Sieverding, Stephan Miller

Erschienen in: Pediatric Radiology | Ausgabe 12/2006

Einloggen, um Zugang zu erhalten

Abstract

Background

Cardiac MRI has become a clinically useful supplement to ECHO and conventional X-ray angiography in the diagnostic work-up of patients with congenital heart disease (CHD). Three-dimensional (3D) sequences are capable of depicting both intracardiac and extracardiac structures with high accuracy in adults and adolescents. However, diagnostic image quality in infants and young children has not yet been reported.

Objective

To apply an optimized 3D steady-state free-precession (SSFP) MR sequence in infants and children with CHD.

Materials and methods

In 20 patients (median age 1.8 years; ten male) with CHD, whole-chest imaging was performed with navigator-gated, isotropic 3D SSFP MRI at 1.5 T. Sequence parameters were adapted to special requirements in infancy. Measurements of intra- and extracardiac structures were performed by two independent observers and compared to spin-echo and cine gradient-recalled-echo sequences.

Results

Diagnostic image quality was achieved with the 3D SSFP technique in all patients, allowing the establishment of a diagnosis in all cases. Interobserver comparison of measurements from reformatted 3D SSFP datasets revealed only minor differences with standard deviations ranging from 0.3–1.3 mm for intracardiac and 0.3–0.7 mm for extracardiac anatomy (P = ns).

Conclusion

Isotropic 3D SSFP MRI allows reliable and accurate assessment of CHD, even in free-breathing infants and young children.
Literatur
1.
Zurück zum Zitat Fletcher BD, Jacobstein MD (1986) MRI of congenital abnormalities of the great arteries. AJR 146:941–948PubMed Fletcher BD, Jacobstein MD (1986) MRI of congenital abnormalities of the great arteries. AJR 146:941–948PubMed
2.
Zurück zum Zitat Geva T, Kreutzer J (2001) Diagnostic pathways for evaluation of congenital heart disease. In: Crawford MH, DiMarco JP (eds) Cardiology. Mosby International, London, pp 1–22 Geva T, Kreutzer J (2001) Diagnostic pathways for evaluation of congenital heart disease. In: Crawford MH, DiMarco JP (eds) Cardiology. Mosby International, London, pp 1–22
3.
Zurück zum Zitat Vitiello R, McCrindle BW, Nykanen D, et al (1998) Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 32:1433–1440PubMedCrossRef Vitiello R, McCrindle BW, Nykanen D, et al (1998) Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 32:1433–1440PubMedCrossRef
4.
Zurück zum Zitat Boxt LM, Rozenshtein A (2003) MR imaging of congenital heart disease. Magn Reson Imaging Clin N Am 11:27–48PubMedCrossRef Boxt LM, Rozenshtein A (2003) MR imaging of congenital heart disease. Magn Reson Imaging Clin N Am 11:27–48PubMedCrossRef
5.
Zurück zum Zitat Geva T, Vick GW, Wendt RE, et al (1994) Role of spin echo and cine magnetic resonance imaging in presurgical planning of heterotaxy syndrome. Comparison with echocardiography and catheterization. Circulation 90:348–356PubMed Geva T, Vick GW, Wendt RE, et al (1994) Role of spin echo and cine magnetic resonance imaging in presurgical planning of heterotaxy syndrome. Comparison with echocardiography and catheterization. Circulation 90:348–356PubMed
6.
Zurück zum Zitat Chung T (2005) Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time resolved technique. Pediatr Radiol 35:3–10PubMedCrossRef Chung T (2005) Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time resolved technique. Pediatr Radiol 35:3–10PubMedCrossRef
7.
Zurück zum Zitat Beerbaum P, Korperich H, Esdorn H, et al (2003) Atrial septal defects in pediatric patients: noninvasive sizing with cardiovascular MR imaging. Radiology 228:361–369PubMedCrossRef Beerbaum P, Korperich H, Esdorn H, et al (2003) Atrial septal defects in pediatric patients: noninvasive sizing with cardiovascular MR imaging. Radiology 228:361–369PubMedCrossRef
8.
Zurück zum Zitat Glockner JF, Johnston DL, McGee KP (2003) Evaluation of cardiac valvular disease with MR imaging: qualitative and quantitative techniques. Radiographics 23:e9PubMedCrossRef Glockner JF, Johnston DL, McGee KP (2003) Evaluation of cardiac valvular disease with MR imaging: qualitative and quantitative techniques. Radiographics 23:e9PubMedCrossRef
9.
Zurück zum Zitat Holmqvist C, Stahlberg F, Hanseus K, et al (2002) Collateral flow in coarctation of the aorta with magnetic resonance velocity mapping: correlation to morphological imaging of collateral vessels. J Magn Reson Imaging 15:39–46PubMedCrossRef Holmqvist C, Stahlberg F, Hanseus K, et al (2002) Collateral flow in coarctation of the aorta with magnetic resonance velocity mapping: correlation to morphological imaging of collateral vessels. J Magn Reson Imaging 15:39–46PubMedCrossRef
10.
Zurück zum Zitat Geva T, Greil GF, Marshall AC, et al (2002) Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: comparison with x-ray angiography. Circulation 106:473–478PubMedCrossRef Geva T, Greil GF, Marshall AC, et al (2002) Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: comparison with x-ray angiography. Circulation 106:473–478PubMedCrossRef
11.
Zurück zum Zitat Greil GF, Powell AJ, Gildein HP, et al (2002) Gadolinium-enhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies. J Am Coll Cardiol 39:335–341PubMedCrossRef Greil GF, Powell AJ, Gildein HP, et al (2002) Gadolinium-enhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies. J Am Coll Cardiol 39:335–341PubMedCrossRef
12.
Zurück zum Zitat Weber OM, Martin AJ, Higgins CB (2003) Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 50:1223–1228PubMedCrossRef Weber OM, Martin AJ, Higgins CB (2003) Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 50:1223–1228PubMedCrossRef
13.
Zurück zum Zitat Razavi RS, Hill DL, Muthurangu V, et al (2003) Three-dimensional magnetic resonance imaging of congenital cardiac anomalies. Cardiol Young 13:461–465PubMed Razavi RS, Hill DL, Muthurangu V, et al (2003) Three-dimensional magnetic resonance imaging of congenital cardiac anomalies. Cardiol Young 13:461–465PubMed
14.
Zurück zum Zitat Sorensen TS, Körperich H, Greil GF, et al (2004) Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study. Circulation 110:163–169PubMedCrossRef Sorensen TS, Körperich H, Greil GF, et al (2004) Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study. Circulation 110:163–169PubMedCrossRef
15.
Zurück zum Zitat Martirosian P, Fenchel M, Greil GF, et al (2005) Blood-myocardial contrast optimization in 3D True-FISP cardiac imaging at 1.5 T. Proceedings of the 13th Annual Meeting of the International Society of Magnetic Resonance in Medicine, Miami, p 1671 Martirosian P, Fenchel M, Greil GF, et al (2005) Blood-myocardial contrast optimization in 3D True-FISP cardiac imaging at 1.5 T. Proceedings of the 13th Annual Meeting of the International Society of Magnetic Resonance in Medicine, Miami, p 1671
16.
Zurück zum Zitat Brittain JH, Hu BS, Wright GA, et al (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMedCrossRef Brittain JH, Hu BS, Wright GA, et al (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMedCrossRef
17.
Zurück zum Zitat Deimling M, Heid O (1994) Magnetization prepared True FISP imaging. Proceedings of the Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495 Deimling M, Heid O (1994) Magnetization prepared True FISP imaging. Proceedings of the Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495
18.
Zurück zum Zitat Botnar RM, Stuber M, Danias PG, et al (1999) Improved coronary artery definition with T2 weighted, free-breathing, three dimensional coronary MRA. Circulation 99:3139–3148PubMed Botnar RM, Stuber M, Danias PG, et al (1999) Improved coronary artery definition with T2 weighted, free-breathing, three dimensional coronary MRA. Circulation 99:3139–3148PubMed
19.
Zurück zum Zitat Van Praagh R (1992) Segmental approach to diagnosis. In: Fyler DC (ed) Nadas’ pediatric cardiology. Hanley & Belfus, Philadelphia, pp 27–35 Van Praagh R (1992) Segmental approach to diagnosis. In: Fyler DC (ed) Nadas’ pediatric cardiology. Hanley & Belfus, Philadelphia, pp 27–35
20.
Zurück zum Zitat Nehrke K, Bornert P, Mazurkewitz P, et al (2006) Free-breathing whole-heart coronary MR angiography on a clinical scanner in four minutes. J Magn Reson Imaging 23:752–756PubMedCrossRef Nehrke K, Bornert P, Mazurkewitz P, et al (2006) Free-breathing whole-heart coronary MR angiography on a clinical scanner in four minutes. J Magn Reson Imaging 23:752–756PubMedCrossRef
21.
Zurück zum Zitat Godart F, Labrot G, Devos P, et al (2002) Coarctation of the aorta: comparison of aortic dimensions between conventional MR imaging, 3D MR angiography, and conventional angiography. Eur Radiol 12:2034–2039PubMed Godart F, Labrot G, Devos P, et al (2002) Coarctation of the aorta: comparison of aortic dimensions between conventional MR imaging, 3D MR angiography, and conventional angiography. Eur Radiol 12:2034–2039PubMed
22.
Zurück zum Zitat Park J, Larson AC, Zhang Q, et al (2005) 4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS). Magn Reson Med 54:833–840PubMedCrossRef Park J, Larson AC, Zhang Q, et al (2005) 4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS). Magn Reson Med 54:833–840PubMedCrossRef
23.
Zurück zum Zitat Didier D, Ratib O, Beghetti M, et al (1999) Morphologic and functional evaluation of congenital heart disease by magnetic resonance imaging. J Magn Reson Imaging 10:639–655PubMedCrossRef Didier D, Ratib O, Beghetti M, et al (1999) Morphologic and functional evaluation of congenital heart disease by magnetic resonance imaging. J Magn Reson Imaging 10:639–655PubMedCrossRef
24.
Zurück zum Zitat Chung T (2000) Assessment of cardiovascular anatomy in patients with congenital heart disease by magnetic resonance imaging. Pediatr Cardiol 21:18–26PubMedCrossRef Chung T (2000) Assessment of cardiovascular anatomy in patients with congenital heart disease by magnetic resonance imaging. Pediatr Cardiol 21:18–26PubMedCrossRef
25.
Zurück zum Zitat Beerbaum P, Korperich H, Gieseke J, et al (2003) Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 108:1355–1361PubMedCrossRef Beerbaum P, Korperich H, Gieseke J, et al (2003) Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 108:1355–1361PubMedCrossRef
Metadaten
Titel
Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease
verfasst von
Michael Fenchel
Gerald F. Greil
Petros Martirosian
Ulrich Kramer
Fritz Schick
Claus D. Claussen
Ludger Sieverding
Stephan Miller
Publikationsdatum
01.12.2006
Verlag
Springer-Verlag
Erschienen in
Pediatric Radiology / Ausgabe 12/2006
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-006-0314-z

Weitere Artikel der Ausgabe 12/2006

Pediatric Radiology 12/2006 Zur Ausgabe

Acknowledgement to Referees

Acknowledgement to referees

Hermes

Events

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.