Skip to main content
Erschienen in: Pediatric Radiology 9/2009

01.09.2009 | Original Article

A prospective study to evaluate the depictability of the hepatic veins on abdominal contrast-enhanced CT in small children

verfasst von: Motoo Nakagawa, Masaki Hara, Yuta Shibamoto

Erschienen in: Pediatric Radiology | Ausgabe 9/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

The optimal conditions for abdominal contrast-enhanced (CE) CT, especially with respect to depiction of the hepatic veins (HVs), have not been well studied in small children.

Objective

We compared the depiction of the HVs in small children using scan delay times of 50 s and 60 s and a power injector. The degree of contrast enhancement of the HVs according to body weight was also evaluated.

Materials and methods

A total of 50 CT studies in 31 children ages 2 days to 3 years 4 months (median 12 months) with a body weight less than 15 kg were prospectively evaluated. Nonionic contrast medium (300 mgI/ml) at a dose of 2 ml/kg and an injection rate calculated as (body weight in kilograms × 0.1) ml/s was injected through a 24-gauge intravenous catheter. Scan delay time was randomly chosen at 50 s or 60 s (25 times each). Subjective assessment of HV depiction was performed and the difference in CT number between the HV and hepatic parenchyma (HV−HP value) was calculated.

Results

In all cases, subjective assessment of HV depiction was good and the HV−HP value was greater than 20 HU. The mean±SD HV−HP value was 47.7±13.2 HU. There were no differences in the mean HV−HP values between scan delay times of 50 s and 60 s (P=0.58).

Conclusion

For small children, this protocol for pediatric abdominal CECT resulted in good depiction of the HVs with no difference between scan delay times of 50 s and 60 s.
Literatur
1.
Zurück zum Zitat Siegel MJ, Babyn PS, Lee EY (2008) Liver and biliary tract. In: Pediatric body CT, 2nd edn. Lippincott Williams & Wilkins, Philadelphia, pp 177–216 Siegel MJ, Babyn PS, Lee EY (2008) Liver and biliary tract. In: Pediatric body CT, 2nd edn. Lippincott Williams & Wilkins, Philadelphia, pp 177–216
2.
Zurück zum Zitat Jacobs JE, Birnbaum BA, Langlotz CP (1998) Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 209:411–416PubMed Jacobs JE, Birnbaum BA, Langlotz CP (1998) Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 209:411–416PubMed
3.
Zurück zum Zitat Amaral JG, Traubici J, BenDavid G et al (2006) Safety of power injector use in children as measured by incidence of extravasation. AJR 187:580–583PubMedCrossRef Amaral JG, Traubici J, BenDavid G et al (2006) Safety of power injector use in children as measured by incidence of extravasation. AJR 187:580–583PubMedCrossRef
4.
Zurück zum Zitat Kaste SC, Young CW (1996) Safe use of power injectors with central and peripheral venous access devices for pediatric CT. Pediatr Radiol 26:499–501PubMedCrossRef Kaste SC, Young CW (1996) Safe use of power injectors with central and peripheral venous access devices for pediatric CT. Pediatr Radiol 26:499–501PubMedCrossRef
5.
Zurück zum Zitat Westra SJ, Hill JA, Alejos JC et al (1999) Three-dimensional helical CT of pulmonary arteries in infants and children with congenital heart disease. AJR 173:109–115PubMed Westra SJ, Hill JA, Alejos JC et al (1999) Three-dimensional helical CT of pulmonary arteries in infants and children with congenital heart disease. AJR 173:109–115PubMed
6.
Zurück zum Zitat Greenberg M, Filler RM (1997) Hepatic tumors. In: Pizzo PA, Poplack DG (eds) Principles and practice of pediatric oncology, 3rd edn. Lippincott Williams & Wilkins, Philadelphia, pp 717–732 Greenberg M, Filler RM (1997) Hepatic tumors. In: Pizzo PA, Poplack DG (eds) Principles and practice of pediatric oncology, 3rd edn. Lippincott Williams & Wilkins, Philadelphia, pp 717–732
7.
Zurück zum Zitat Golli M, Kriaa S, Said M et al (2000) Intrahepatic spontaneous portosystemic venous shunt: value of color and power Doppler sonography. J Clin Ultrasound 28:47–50PubMedCrossRef Golli M, Kriaa S, Said M et al (2000) Intrahepatic spontaneous portosystemic venous shunt: value of color and power Doppler sonography. J Clin Ultrasound 28:47–50PubMedCrossRef
8.
Zurück zum Zitat Luker GD, Siegel MJ, Bradley DA et al (1996) Hepatic spiral CT in children: scan delay time-enhancement analysis. Pediatr Radiol 26:337–340PubMedCrossRef Luker GD, Siegel MJ, Bradley DA et al (1996) Hepatic spiral CT in children: scan delay time-enhancement analysis. Pediatr Radiol 26:337–340PubMedCrossRef
9.
Zurück zum Zitat Donnelly LF, Frush DP (2003) Pediatric multidetector body CT. Radiol Clin North Am 41:637–655PubMedCrossRef Donnelly LF, Frush DP (2003) Pediatric multidetector body CT. Radiol Clin North Am 41:637–655PubMedCrossRef
10.
Zurück zum Zitat Thomsen HS, Morcos SK (2003) Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines. Br J Radiol 76:513–518PubMedCrossRef Thomsen HS, Morcos SK (2003) Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines. Br J Radiol 76:513–518PubMedCrossRef
11.
Zurück zum Zitat Nash K, Hafeez A, Hou S (2002) Hospital-acquired renal insufficiency. Am J Kidney Dis 39:930–936PubMedCrossRef Nash K, Hafeez A, Hou S (2002) Hospital-acquired renal insufficiency. Am J Kidney Dis 39:930–936PubMedCrossRef
12.
Zurück zum Zitat Niboshi A, Nishida M, Itoi T et al (2006) Renal function and cardiac angiography. Indian J Pediatr 73:49–53PubMedCrossRef Niboshi A, Nishida M, Itoi T et al (2006) Renal function and cardiac angiography. Indian J Pediatr 73:49–53PubMedCrossRef
13.
Zurück zum Zitat Heiken JP, Menias CO (2006) Liver. In: Lee JK, Sagel SS, Stanley RJ et al (eds) Computed body tomography with MRI correlation, 4th edn. Lippincott Williams & Wilkins, Philadelphia, pp 829–931 Heiken JP, Menias CO (2006) Liver. In: Lee JK, Sagel SS, Stanley RJ et al (eds) Computed body tomography with MRI correlation, 4th edn. Lippincott Williams & Wilkins, Philadelphia, pp 829–931
14.
Zurück zum Zitat Keane V (2007) Assessment of growth. In: Kliegman RM, Behrman RE, Jenson HB et al (eds) Nelson’s textbook of pediatrics, 18th edn. Elsevier, Philadelphia, pp 70–74 Keane V (2007) Assessment of growth. In: Kliegman RM, Behrman RE, Jenson HB et al (eds) Nelson’s textbook of pediatrics, 18th edn. Elsevier, Philadelphia, pp 70–74
15.
Zurück zum Zitat Du Bois D, Du Bois EF (1989) A formula to estimate the approximate surface area if height and weight be known. Nutrition 5:303–311PubMed Du Bois D, Du Bois EF (1989) A formula to estimate the approximate surface area if height and weight be known. Nutrition 5:303–311PubMed
16.
Zurück zum Zitat Haycock GB, Schwartz GJ, Wisotsky DH (1978) Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 93:62–66PubMedCrossRef Haycock GB, Schwartz GJ, Wisotsky DH (1978) Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 93:62–66PubMedCrossRef
Metadaten
Titel
A prospective study to evaluate the depictability of the hepatic veins on abdominal contrast-enhanced CT in small children
verfasst von
Motoo Nakagawa
Masaki Hara
Yuta Shibamoto
Publikationsdatum
01.09.2009
Verlag
Springer-Verlag
Erschienen in
Pediatric Radiology / Ausgabe 9/2009
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-009-1302-x

Weitere Artikel der Ausgabe 9/2009

Pediatric Radiology 9/2009 Zur Ausgabe

Hermes

Hermes

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.