Abstract

Background

Percutaneous biopsies of soft-tissue organs are frequently performed using US guidance. US permits visualization of blood flow on color Doppler imaging.

Objective

To report the presence of color Doppler signal (positive color Doppler sign) along the biopsy tract after percutaneous needle biopsy of the liver and kidney as an indication of bleeding and to describe US-guided hemostasis.

Materials and methods

A case-control study of US-guided liver and kidney biopsies performed between January 2005 and September 2009 was undertaken. All pediatric patients with a positive color Doppler sign along the biopsy tract were included. Controls consisted of patients in whom no color Doppler sign was identified.

Results

Fifty-three cases with positive color Doppler sign were identified. One hundred and six matched controls were selected. The average compression time was 9.2 min in kidney and 8.4 min in liver cases. US-guided compression achieved cessation of the positive color Doppler sign in all cases. There was no significant difference between the mean pre- and post-procedure hemoglobin and platelet levels between kidney cases and controls (P = 0.68 and P = 0.63, respectively) and between liver cases and controls (P = 0.45 and P = 0.80).

Conclusion

Color Doppler US can detect bleeding post percutaneous liver and kidney biopsies. US-guided compression is effective in obliterating the color Doppler signal and achieving appropriate hemostasis.
Literatur
1.
Zurück zum Zitat Long BW (2000) Image-guided percutaneous needle biopsy: an overview. Radiol Technol 71:335–359, quiz 360–363PubMed Long BW (2000) Image-guided percutaneous needle biopsy: an overview. Radiol Technol 71:335–359, quiz 360–363PubMed
2.
Zurück zum Zitat Bach D, Hanraths M, Maar K et al (1998) Ultrasound guided percutaneous biopsy or operative biopsy in patients with kidney impairment? Int Urol Nephrol 20:519–523CrossRef Bach D, Hanraths M, Maar K et al (1998) Ultrasound guided percutaneous biopsy or operative biopsy in patients with kidney impairment? Int Urol Nephrol 20:519–523CrossRef
3.
Zurück zum Zitat Caturelli E, Giacobbe A, Facciorusso D et al (1996) Percutaneous biopsy in diffuse liver disease: increasing diagnostic yield and decreasing complication rate by routine ultrasound assessment of puncture site. Am J Gastroenterol 91:1318–1321PubMed Caturelli E, Giacobbe A, Facciorusso D et al (1996) Percutaneous biopsy in diffuse liver disease: increasing diagnostic yield and decreasing complication rate by routine ultrasound assessment of puncture site. Am J Gastroenterol 91:1318–1321PubMed
4.
Zurück zum Zitat Pasha T, Gabriel S, Therneau T et al (1998) Cost-effectiveness of ultrasound-guided liver biopsy. Hepatology 27:1220–1226CrossRefPubMed Pasha T, Gabriel S, Therneau T et al (1998) Cost-effectiveness of ultrasound-guided liver biopsy. Hepatology 27:1220–1226CrossRefPubMed
5.
Zurück zum Zitat Sebire N, Roebuck D (2006) Pathological diagnosis of pediatric tumours from image-guided needle core biopsies: a systematic review. Pediatr Radiol 36:426–431CrossRefPubMed Sebire N, Roebuck D (2006) Pathological diagnosis of pediatric tumours from image-guided needle core biopsies: a systematic review. Pediatr Radiol 36:426–431CrossRefPubMed
6.
Zurück zum Zitat Chahal PS, Ready J (2002) Hemothorax after percutaneous liver biopsy: an unusual complication. Am J Gastroenterol 97:1068–1069CrossRefPubMed Chahal PS, Ready J (2002) Hemothorax after percutaneous liver biopsy: an unusual complication. Am J Gastroenterol 97:1068–1069CrossRefPubMed
7.
Zurück zum Zitat Eiro M, Katoh T, Watanabe T (2005) Risk factors for bleeding complications in percutaneous kidney biopsy. Clin Exp Nephrol 9:40–45CrossRefPubMed Eiro M, Katoh T, Watanabe T (2005) Risk factors for bleeding complications in percutaneous kidney biopsy. Clin Exp Nephrol 9:40–45CrossRefPubMed
8.
Zurück zum Zitat Hoffer FA (2000) Liver biopsy methods for pediatric oncology patients. Pediatr Radiol 30:481–488CrossRefPubMed Hoffer FA (2000) Liver biopsy methods for pediatric oncology patients. Pediatr Radiol 30:481–488CrossRefPubMed
9.
Zurück zum Zitat Omary RA, Bettmann MA, Cardella JF et al (2003) Quality improvement guidelines for the reporting and archiving of interventional radiology procedures. J Vasc Interv Radiol 14(9 Pt 2):S293–295PubMed Omary RA, Bettmann MA, Cardella JF et al (2003) Quality improvement guidelines for the reporting and archiving of interventional radiology procedures. J Vasc Interv Radiol 14(9 Pt 2):S293–295PubMed
10.
Zurück zum Zitat Chesney DS, Brouhard BH, Cunningham RJ (1996) Safety and cost effectiveness of pediatric percutaneous kidney biopsy. Pediatr Nephrol 10:493–495CrossRefPubMed Chesney DS, Brouhard BH, Cunningham RJ (1996) Safety and cost effectiveness of pediatric percutaneous kidney biopsy. Pediatr Nephrol 10:493–495CrossRefPubMed
11.
Zurück zum Zitat Feneberg R, Schaefer F, Zieger B et al (1998) Percutaneous kidney biopsy in children: a 27-year experience. Nephron 79:438–446CrossRefPubMed Feneberg R, Schaefer F, Zieger B et al (1998) Percutaneous kidney biopsy in children: a 27-year experience. Nephron 79:438–446CrossRefPubMed
12.
Zurück zum Zitat Waldo B, Korbet SM, Freimanis MG et al (2009) The value of post-biopsy ultrasound in predicting complications after percutaneous kidney biopsy of native kidneys. Nephrol Dial Transplant 24:2433–2439CrossRefPubMed Waldo B, Korbet SM, Freimanis MG et al (2009) The value of post-biopsy ultrasound in predicting complications after percutaneous kidney biopsy of native kidneys. Nephrol Dial Transplant 24:2433–2439CrossRefPubMed
14.
Zurück zum Zitat Stratta P, Canavese C, Marengo M et al (2007) Risk management of kidney biopsy: 1, 387 cases over 30 years in a single centre. Eur J Clin Investig 37:954–963CrossRef Stratta P, Canavese C, Marengo M et al (2007) Risk management of kidney biopsy: 1, 387 cases over 30 years in a single centre. Eur J Clin Investig 37:954–963CrossRef
15.
Zurück zum Zitat McVay PA, Toy PT (1990) Lack of increased bleeding after liver biopsy in patients with mild hemostatic abnormalities. Am J Clin Pathol 94:747–753PubMed McVay PA, Toy PT (1990) Lack of increased bleeding after liver biopsy in patients with mild hemostatic abnormalities. Am J Clin Pathol 94:747–753PubMed
16.
Zurück zum Zitat Amaral JG, Schwartz J, Chait P et al (2006) Sonographically guided percutaneous liver biopsy in infants: a retrospective review. Am J Roentgenol 187:W644–W649CrossRef Amaral JG, Schwartz J, Chait P et al (2006) Sonographically guided percutaneous liver biopsy in infants: a retrospective review. Am J Roentgenol 187:W644–W649CrossRef
Metadaten
Titel
The positive color Doppler sign post biopsy: effectiveness of US-directed compression in achieving hemostasis
verfasst von
Mohammed Alotaibi
Jason Shrouder-Henry
Joao Amaral
Dimitri Parra
Michael Temple
Philip John
Bairbre Connolly
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
Pediatric Radiology / Ausgabe 3/2011
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-010-1848-7

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.