01.08.2006 | Editorial

Putting ‘clear’ into nuclear medicine: a decade of PET/CT development

verfasst von: Thomas Beyer, David W. Townsend

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 8/2006

Einloggen, um Zugang zu erhalten

Excerpt

Combining data from different imaging modalities is far from being a new idea. Hand-drawn contours on early thyroid scans constituted a rough anatomical reference for images of thyroid function acquired using trace amounts of radioactive iodine. When analogue imaging with planar X-rays and Polaroid photos of radiotracer distributions gave way to the digital imaging era of the CT scanner and emission tomography, visual correlation of structure and function became possible. The next step, beginning in the late 1980s, was the development of computer software to co-register the images from different modalities, a development that was applied primarily to brain imaging. However, even though non-invasive anatomical and functional imaging became well-established diagnostic procedures within radiology and nuclear medicine, little attention was actually paid to the co-registration of images from the different modalities. What were the reasons for this? One reason was that accurate registration of anatomy and function was never really considered essential for the interpretation of the images and access to multimodality data was rarely routine and certainly not straightforward. Furthermore, anatomical and functional images were typically acquired in different departments and read by different specialists, a situation that did little to promote the use of software fusion techniques. Thus, up until the mid 1990s, and despite the expenditure of considerable intellectual effort, image fusion techniques had little impact on public healthcare. The arrival of PET/CT has changed this situation forever. …
Literatur
1.
Zurück zum Zitat Townsend DW, Cherry SR. Combining anatomy with function: the path to true image fusion. Eur Radiol 2001;11:1968–74PubMedCrossRef Townsend DW, Cherry SR. Combining anatomy with function: the path to true image fusion. Eur Radiol 2001;11:1968–74PubMedCrossRef
2.
Zurück zum Zitat Townsend D, Beyer T, Kinahan P, et al. The SMART scanner: a combined PET/CT tomograph for clinical oncology. Radiology 1998;209(P):169–70 Townsend D, Beyer T, Kinahan P, et al. The SMART scanner: a combined PET/CT tomograph for clinical oncology. Radiology 1998;209(P):169–70
3.
Zurück zum Zitat Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT tomograph for clinical oncology. J Nucl Med 2000;41:1369–79PubMed Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT tomograph for clinical oncology. J Nucl Med 2000;41:1369–79PubMed
4.
Zurück zum Zitat Charron M, Beyer T, Bohnen NN, Kinahan PE, Dachille M, Jerin J, et al. Image analysis in patients with cancer studied with a combined PET and CT scanner. Clin Nucl Med 2000;25:905–91PubMedCrossRef Charron M, Beyer T, Bohnen NN, Kinahan PE, Dachille M, Jerin J, et al. Image analysis in patients with cancer studied with a combined PET and CT scanner. Clin Nucl Med 2000;25:905–91PubMedCrossRef
5.
Zurück zum Zitat Kluetz PG, Meltzer CC, Villemagne VL, Kinahan PE, Chander S, Martinelli MA, et al. Combined PET/CT imaging in oncology: impact on patient management. Clinical Positron Imaging 2000;3:223–30CrossRefPubMed Kluetz PG, Meltzer CC, Villemagne VL, Kinahan PE, Chander S, Martinelli MA, et al. Combined PET/CT imaging in oncology: impact on patient management. Clinical Positron Imaging 2000;3:223–30CrossRefPubMed
6.
Zurück zum Zitat Jaroff L. A winning combination. TIME Magazine 2000;156(23):72–4 Jaroff L. A winning combination. TIME Magazine 2000;156(23):72–4
7.
Zurück zum Zitat Wiley G. Disruptive technology: the conflict over PET/CT. Decis Imaging Econ 2005;June Issue:17–20 Wiley G. Disruptive technology: the conflict over PET/CT. Decis Imaging Econ 2005;June Issue:17–20
8.
Zurück zum Zitat Jager P, Slart R, Corstens F, Oyen W, Hockstra O, Teule J. PET-CT: a matter of opinion. Eur J Nucl Med Mol Imaging 2003;30:470–1PubMedCrossRef Jager P, Slart R, Corstens F, Oyen W, Hockstra O, Teule J. PET-CT: a matter of opinion. Eur J Nucl Med Mol Imaging 2003;30:470–1PubMedCrossRef
9.
Zurück zum Zitat Lemke A-J, Niehues SM, Hosten N, Amthauer H, Boehmig M, Stroszczynski C, et al. Retrospective digital image fusion of multidetector CT and 18F-FDG PET: clinical value in pancreatic lesions—a prospective study with 104 patients. J Nucl Med 2004;45:1279–86PubMed Lemke A-J, Niehues SM, Hosten N, Amthauer H, Boehmig M, Stroszczynski C, et al. Retrospective digital image fusion of multidetector CT and 18F-FDG PET: clinical value in pancreatic lesions—a prospective study with 104 patients. J Nucl Med 2004;45:1279–86PubMed
10.
Zurück zum Zitat Slomka PJ. Software approach to merging molecular with anatomic information. J Nucl Med 2004;45:36S–45SPubMed Slomka PJ. Software approach to merging molecular with anatomic information. J Nucl Med 2004;45:36S–45SPubMed
11.
Zurück zum Zitat Shekhar R, Walimbe V, Raja S, Zagrodsky V, Kanvinde M, Wu G, et al. Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners. J Nucl Med 2005;46:1488–96PubMed Shekhar R, Walimbe V, Raja S, Zagrodsky V, Kanvinde M, Wu G, et al. Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners. J Nucl Med 2005;46:1488–96PubMed
12.
Zurück zum Zitat Pietrzyk U. Does PET/CT render software fusion obsolete? Nuklearmedizin 2005;44:S13–7PubMed Pietrzyk U. Does PET/CT render software fusion obsolete? Nuklearmedizin 2005;44:S13–7PubMed
13.
Zurück zum Zitat Pannu HK, Bristow RE, Cohade C, Fishman EK, Wahl RL. PET-CT in recurrent ovarian cancer: initial observations. Radiographics 2004;24:209–23PubMedCrossRef Pannu HK, Bristow RE, Cohade C, Fishman EK, Wahl RL. PET-CT in recurrent ovarian cancer: initial observations. Radiographics 2004;24:209–23PubMedCrossRef
14.
Zurück zum Zitat Branstetter BF 4th, Blodgett TM, Zimmer LA, Snyderman CH, Johnson JT, Raman S, et al. Head and neck malignancy: is PET/CT more accurate than PET or CT alone? Radiology 2005;235:580–6PubMedCrossRef Branstetter BF 4th, Blodgett TM, Zimmer LA, Snyderman CH, Johnson JT, Raman S, et al. Head and neck malignancy: is PET/CT more accurate than PET or CT alone? Radiology 2005;235:580–6PubMedCrossRef
15.
Zurück zum Zitat von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol 2000;10:S377–80CrossRef von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol 2000;10:S377–80CrossRef
16.
Zurück zum Zitat Kinahan PE, Townsend DW, Beyer T, Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998;25:2046–53PubMedCrossRef Kinahan PE, Townsend DW, Beyer T, Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998;25:2046–53PubMedCrossRef
17.
Zurück zum Zitat Townsend D, Carney JP, Yap JT, Hall NC. PET/CT today and tomorrow. J Nucl Med 2004;45:4S–14SPubMed Townsend D, Carney JP, Yap JT, Hall NC. PET/CT today and tomorrow. J Nucl Med 2004;45:4S–14SPubMed
18.
Zurück zum Zitat Townsend D, Beyer T. Anato-molecular imaging: combining structure and function. In: Bailey DL, Townsend DW, Valk PE, Maisey MN, editors. Positron emission tomography: principles and practice. London: Springer; 2005. p 179–202CrossRef Townsend D, Beyer T. Anato-molecular imaging: combining structure and function. In: Bailey DL, Townsend DW, Valk PE, Maisey MN, editors. Positron emission tomography: principles and practice. London: Springer; 2005. p 179–202CrossRef
19.
Zurück zum Zitat Pfannenberg A, Eschmann S, Brechtel K, et al. A new high-resolution, multi-slice PET/CT tomograph for state-of-the-art oncology imaging—radiologist’s perspective. J Nucl Med 2005;46:414P Pfannenberg A, Eschmann S, Brechtel K, et al. A new high-resolution, multi-slice PET/CT tomograph for state-of-the-art oncology imaging—radiologist’s perspective. J Nucl Med 2005;46:414P
20.
Zurück zum Zitat Moses W. Time of flight in PET revisited. IEEE Trans Nucl Sci 2003;50:1325–30CrossRef Moses W. Time of flight in PET revisited. IEEE Trans Nucl Sci 2003;50:1325–30CrossRef
21.
Zurück zum Zitat Townsend DW, Isoardi RA, Bendriem B. Volume imaging tomographs. In: Townsend DW, Bendriem B, editors. Theory and practice of 3D PET. Dordrecht: Kluwer Academic; 1998. p 111–32 Townsend DW, Isoardi RA, Bendriem B. Volume imaging tomographs. In: Townsend DW, Bendriem B, editors. Theory and practice of 3D PET. Dordrecht: Kluwer Academic; 1998. p 111–32
22.
Zurück zum Zitat Lodge MA, Badawi RD, Gilbert R, Dibos PE, Line BR. Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. J Nucl Med 2006;47:23–31PubMed Lodge MA, Badawi RD, Gilbert R, Dibos PE, Line BR. Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. J Nucl Med 2006;47:23–31PubMed
23.
Zurück zum Zitat Visvikis D, Griffiths D, Costa D, Bomanji J, Ell P. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner. Eur J Nucl Med Mol Imaging 2005;32:1050–6PubMedCrossRef Visvikis D, Griffiths D, Costa D, Bomanji J, Ell P. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner. Eur J Nucl Med Mol Imaging 2005;32:1050–6PubMedCrossRef
24.
Zurück zum Zitat Votaw JR, White M. Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies. J Nucl Med 2001;42:701–6PubMed Votaw JR, White M. Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies. J Nucl Med 2001;42:701–6PubMed
25.
Zurück zum Zitat Ferreira NC, Trébossen R, Bendriem B. Assessment of 3-D PET quantitation: influence of out of the field of view radioactive sources and of attenuating media. IEEE Trans Nucl Sci 1998;45:1670–5CrossRef Ferreira NC, Trébossen R, Bendriem B. Assessment of 3-D PET quantitation: influence of out of the field of view radioactive sources and of attenuating media. IEEE Trans Nucl Sci 1998;45:1670–5CrossRef
26.
27.
Zurück zum Zitat Flohr T, McCollough C, Bruder H, Petersilka M, Gruber K, Suss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006;16:256–68PubMedCrossRef Flohr T, McCollough C, Bruder H, Petersilka M, Gruber K, Suss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006;16:256–68PubMedCrossRef
28.
Zurück zum Zitat Burger C, Goerres G, Schoenes S, Buck A, Lonn AHR, Schulthess GKv. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging 2002;29:922–92PubMedCrossRef Burger C, Goerres G, Schoenes S, Buck A, Lonn AHR, Schulthess GKv. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging 2002;29:922–92PubMedCrossRef
29.
Zurück zum Zitat Kinahan P, Hasegawa B, Beyer T. X-ray based attenuation correction for PET/CT scanners. Semin Nucl Med 2003;XXXIII:166–79CrossRef Kinahan P, Hasegawa B, Beyer T. X-ray based attenuation correction for PET/CT scanners. Semin Nucl Med 2003;XXXIII:166–79CrossRef
30.
Zurück zum Zitat Watson CC, Rappoport V, Faul D, Townsend DW, Carney JPJ. A method for calibrating the CT-based attenuation correction of PET in human tissue. IEEE Trans Nucl Sci 2006; in press Watson CC, Rappoport V, Faul D, Townsend DW, Carney JPJ. A method for calibrating the CT-based attenuation correction of PET in human tissue. IEEE Trans Nucl Sci 2006; in press
31.
Zurück zum Zitat Beyer T, Bockisch A, Kuhl H, Martinez M-J. Whole-body 18F-FDG PET/CT in the presence of truncation artifacts. J Nucl Med 2006;47:91–9PubMed Beyer T, Bockisch A, Kuhl H, Martinez M-J. Whole-body 18F-FDG PET/CT in the presence of truncation artifacts. J Nucl Med 2006;47:91–9PubMed
32.
Zurück zum Zitat Brechtel K, Klein M, Vogel M, Mueller M, Aschoff P, Beyer T, et al. Optimized contrast enhanced CT protocols for diagnostic whole-body 18F-FDG PET/CT: single-phase versus multi-phase CT imaging. J Nucl Med 2006;47(3):470–6PubMed Brechtel K, Klein M, Vogel M, Mueller M, Aschoff P, Beyer T, et al. Optimized contrast enhanced CT protocols for diagnostic whole-body 18F-FDG PET/CT: single-phase versus multi-phase CT imaging. J Nucl Med 2006;47(3):470–6PubMed
33.
Zurück zum Zitat Bockisch A, Beyer T, Antoch G, Freudenberg LS, Kuhl H, Debatin JF, et al. Positron emission tomography/computed tomography—imaging protocols, artifacts, and pitfalls. Mol Imaging Biol 2004;6:188–99PubMedCrossRef Bockisch A, Beyer T, Antoch G, Freudenberg LS, Kuhl H, Debatin JF, et al. Positron emission tomography/computed tomography—imaging protocols, artifacts, and pitfalls. Mol Imaging Biol 2004;6:188–99PubMedCrossRef
34.
Zurück zum Zitat Kuehl H, Antoch G. How much CT do we need for PET/CT? A radiologist’s perspective. Nuklearmedizin 2005;44:S24–31PubMed Kuehl H, Antoch G. How much CT do we need for PET/CT? A radiologist’s perspective. Nuklearmedizin 2005;44:S24–31PubMed
35.
Zurück zum Zitat Strobel K, Thuerl CM, Hany T. How much intravenous contrast is needed in FDG-PET/CT? Nuklearmedizin 2005;44:S32–7PubMed Strobel K, Thuerl CM, Hany T. How much intravenous contrast is needed in FDG-PET/CT? Nuklearmedizin 2005;44:S32–7PubMed
36.
Zurück zum Zitat Beyer T. Towards truly integrated hardware fusion with PET/CT. Nuklearmedizin 2005;44:S5–S12PubMed Beyer T. Towards truly integrated hardware fusion with PET/CT. Nuklearmedizin 2005;44:S5–S12PubMed
37.
Zurück zum Zitat Therasse P, Arbuck SG, Eisenhauer EA, Wanders J, Kaplan RS, Rubinstein L, et al. New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 2000;92:205–16PubMedCrossRef Therasse P, Arbuck SG, Eisenhauer EA, Wanders J, Kaplan RS, Rubinstein L, et al. New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 2000;92:205–16PubMedCrossRef
Metadaten
Titel
Putting ‘clear’ into nuclear medicine: a decade of PET/CT development
verfasst von
Thomas Beyer
David W. Townsend
Publikationsdatum
01.08.2006
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 8/2006
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-006-0137-z

Weitere Artikel der Ausgabe 8/2006

European Journal of Nuclear Medicine and Molecular Imaging 8/2006 Zur Ausgabe