Routine quality control recommendations for nuclear medicine instrumentation

verfasst von: Ellinor Busemann Sokole, Anna Płachcínska, Alan Britten, Maria Lyra Georgosopoulou, Wendy Tindale, Rigobert Klett, On behalf of the EANM Physics Committee:, With contribution from the EANM Working Group on Nuclear Medicine Instrumentation Quality Control:

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Excerpt

These recommendations cover routine quality control (QC) of instrumentation used within a nuclear medicine department. Routine QC testing starts after installation of the instrument, and after acceptance testing, and continues on a regular basis throughout its lifetime. Additional periodic tests may be carried out to provide more in-depth testing. Recommendations for acceptance testing are covered in a separate document. These recommendations must be considered in the light of any national guidelines and legislation, which must be followed. The recommendations cover the types of tests to be performed, and suggested frequencies, but they do not specify the protocols to be followed, which are available from other reference sources quoted. …
Literatur
1.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA NU 1. Performance measurement of scintillation cameras. Rosslyn, VA: National Electrical Manufacturers Association; 2001, 2007. National Electrical Manufacturers Association. NEMA NU 1. Performance measurement of scintillation cameras. Rosslyn, VA: National Electrical Manufacturers Association; 2001, 2007.
2.
Zurück zum Zitat International Electrotechnical Commission. IEC 60789. Medical electrical equipment – Characteristics and test conditions of radionuclide imaging devices – Anger type gamma cameras. Geneva: International Electrotechnical Commission; 2005. International Electrotechnical Commission. IEC 60789. Medical electrical equipment – Characteristics and test conditions of radionuclide imaging devices – Anger type gamma cameras. Geneva: International Electrotechnical Commission; 2005.
3.
Zurück zum Zitat International Electrotechnical Commission. IEC 61675-2. Radionuclide imaging devices – Characteristics and test conditions – Part 2: Single photon emission computed tomographs. Consolidated Edition 1.1. Geneva: International Electrotechnical Commission; 2005. International Electrotechnical Commission. IEC 61675-2. Radionuclide imaging devices – Characteristics and test conditions – Part 2: Single photon emission computed tomographs. Consolidated Edition 1.1. Geneva: International Electrotechnical Commission; 2005.
4.
Zurück zum Zitat International Electrotechnical Commission. IEC 61675-3. Radionuclide imaging devices – Characteristics and test conditions – Part 3: Gamma camera based whole body imaging systems. Ed 1. Geneva: International Electrotechnical Commission; 1998. International Electrotechnical Commission. IEC 61675-3. Radionuclide imaging devices – Characteristics and test conditions – Part 3: Gamma camera based whole body imaging systems. Ed 1. Geneva: International Electrotechnical Commission; 1998.
5.
Zurück zum Zitat Deutsches Institut für Normung. DIN 6855-2:2005-01. Quality control of nuclear medicine instruments. Part 2: Constancy testing of single crystal gamma-cameras used in planar scintigraphy and in Anger type gamma cameras with rotating detector heads used in single photon emission tomography. Berlin: Deutsches Institut für Normung. Deutsches Institut für Normung. DIN 6855-2:2005-01. Quality control of nuclear medicine instruments. Part 2: Constancy testing of single crystal gamma-cameras used in planar scintigraphy and in Anger type gamma cameras with rotating detector heads used in single photon emission tomography. Berlin: Deutsches Institut für Normung.
8.
Zurück zum Zitat Hines H, Kayayan R, Colsher J, Hashimoto D, Schubert R, Fernando J, et al. Recommendations for implementing SPECT instrumentation quality control. Nuclear Medicine Section – National Electrical Manufacturers Association (NEMA). Eur Nucl Med 1999;26(5):527–32.CrossRef Hines H, Kayayan R, Colsher J, Hashimoto D, Schubert R, Fernando J, et al. Recommendations for implementing SPECT instrumentation quality control. Nuclear Medicine Section – National Electrical Manufacturers Association (NEMA). Eur Nucl Med 1999;26(5):527–32.CrossRef
9.
Zurück zum Zitat Busemann-Sokole E. Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT. J Nucl Med 1987;28:1592–8.PubMed Busemann-Sokole E. Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT. J Nucl Med 1987;28:1592–8.PubMed
10.
Zurück zum Zitat Blokland JA, Camps JA, Pauwels EK. Aspects of performance assessment of whole body imaging systems. Eur J Nucl Med 1997;24(10):1273–83.CrossRefPubMed Blokland JA, Camps JA, Pauwels EK. Aspects of performance assessment of whole body imaging systems. Eur J Nucl Med 1997;24(10):1273–83.CrossRefPubMed
11.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA NU 2. Performance measurements of positron emission tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 1994, 2001, 2007. National Electrical Manufacturers Association. NEMA NU 2. Performance measurements of positron emission tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 1994, 2001, 2007.
12.
Zurück zum Zitat Turkington TG. Introduction to PET instrumentation. J Nucl Med Technol 2001;29:4–11.PubMed Turkington TG. Introduction to PET instrumentation. J Nucl Med Technol 2001;29:4–11.PubMed
13.
Zurück zum Zitat Fahey FH. Data acquisition in PET imaging. J Nucl Med Technol 2002;30:39–49.PubMed Fahey FH. Data acquisition in PET imaging. J Nucl Med Technol 2002;30:39–49.PubMed
14.
Zurück zum Zitat Daube-Witherspoon ME, Karp JS, Casey ME, DiFilippo FP, Hines H, Muehllehner G, et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43(10):1398–409.PubMed Daube-Witherspoon ME, Karp JS, Casey ME, DiFilippo FP, Hines H, Muehllehner G, et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43(10):1398–409.PubMed
15.
Zurück zum Zitat von Schulthess GK. Positron emission tomography versus positron emission tomography/computed tomography: from “unclear” to “new-clear” medicine. Mol Imaging Biol 2004;6(4):183–7.CrossRef von Schulthess GK. Positron emission tomography versus positron emission tomography/computed tomography: from “unclear” to “new-clear” medicine. Mol Imaging Biol 2004;6(4):183–7.CrossRef
16.
Zurück zum Zitat International Electrotechnical Commission. IEC/TR 61948. Nuclear medicine instrumentation – Routine tests – Part 3: Positron emission tomographs. Geneva: International Electrotechnical Commission; 2005. International Electrotechnical Commission. IEC/TR 61948. Nuclear medicine instrumentation – Routine tests – Part 3: Positron emission tomographs. Geneva: International Electrotechnical Commission; 2005.
17.
Zurück zum Zitat Bergmann H, Dobrozemsky G, Minear G, Nicoletti R, Samal M. An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU-2 2001 procedure for assessment of image quality. Phys Med Biol 2005;50:2193–207.CrossRefPubMed Bergmann H, Dobrozemsky G, Minear G, Nicoletti R, Samal M. An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU-2 2001 procedure for assessment of image quality. Phys Med Biol 2005;50:2193–207.CrossRefPubMed
18.
Zurück zum Zitat Zanzonico P. Routine quality control of clinical nuclear medicine instrumentation: a brief review. J Nucl Med 2008;49(7):1114–31.CrossRefPubMed Zanzonico P. Routine quality control of clinical nuclear medicine instrumentation: a brief review. J Nucl Med 2008;49(7):1114–31.CrossRefPubMed
20.
Zurück zum Zitat Lin PJP, Beck TJ, Borras C, et al. Specification and acceptance testing of computed tomography scanners. New York: American Association of Physicists in Medicine; 1993. Lin PJP, Beck TJ, Borras C, et al. Specification and acceptance testing of computed tomography scanners. New York: American Association of Physicists in Medicine; 1993.
21.
Zurück zum Zitat Shepard SJ, Lin PJP, Boone JM, et al. Quality control in diagnostic radiology. College Park: American Association of Physicists in Medicine; 2002. p. 1–74. Shepard SJ, Lin PJP, Boone JM, et al. Quality control in diagnostic radiology. College Park: American Association of Physicists in Medicine; 2002. p. 1–74.
24.
Zurück zum Zitat International Electrotechnical Commission. IEC/TR 61948 series. Nuclear medicine instrumentation – Routine tests – Part 4: Radionuclide calibrators (IEC 2006-11). Geneva: International Electrotechnical Commission. International Electrotechnical Commission. IEC/TR 61948 series. Nuclear medicine instrumentation – Routine tests – Part 4: Radionuclide calibrators (IEC 2006-11). Geneva: International Electrotechnical Commission.
25.
Zurück zum Zitat Deutsches Institut für Normung. DIN 6855-11:2009-05. Constancy testing of nuclear medicine measuring systems – part 11: Radionuclide calibrators (IEC/TR 61948-4:2006, modified). Berlin: Deutsches Institut für Normung. Deutsches Institut für Normung. DIN 6855-11:2009-05. Constancy testing of nuclear medicine measuring systems – part 11: Radionuclide calibrators (IEC/TR 61948-4:2006, modified). Berlin: Deutsches Institut für Normung.
29.
Zurück zum Zitat Deutsches Institut für Normung. DIN 6855-1: 2009-07. Constancy testing of nuclear medicine measuring systems – Part 1: Radiation counting systems for measurements in vivo and in vitro (IEC/TR 61948–1:2001, modified). Berlin: Deutsches Institut für Normung. Deutsches Institut für Normung. DIN 6855-1: 2009-07. Constancy testing of nuclear medicine measuring systems – Part 1: Radiation counting systems for measurements in vivo and in vitro (IEC/TR 61948–1:2001, modified). Berlin: Deutsches Institut für Normung.
30.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA NU 3. Performance measurements and quality control guidelines for non-imaging intraoperative gamma probes, Rosslyn, VA: National Electrical Manufacturers Association; 2004. National Electrical Manufacturers Association. NEMA NU 3. Performance measurements and quality control guidelines for non-imaging intraoperative gamma probes, Rosslyn, VA: National Electrical Manufacturers Association; 2004.
31.
Zurück zum Zitat Zanzonico P, Heller S. The intraoperative gamma probe: basic principles and choices available. Semin Nucl Med 2000;30(1):33–48.CrossRefPubMed Zanzonico P, Heller S. The intraoperative gamma probe: basic principles and choices available. Semin Nucl Med 2000;30(1):33–48.CrossRefPubMed
32.
Zurück zum Zitat Halkar RK, Aarsvold JN. Intraoperative probes. J Nucl Med Technol 1999;27(3):188–93.PubMed Halkar RK, Aarsvold JN. Intraoperative probes. J Nucl Med Technol 1999;27(3):188–93.PubMed
33.
Zurück zum Zitat Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localisation. Eur J Nucl Med 1999;26(2):76–83.CrossRefPubMed Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localisation. Eur J Nucl Med 1999;26(2):76–83.CrossRefPubMed
34.
Zurück zum Zitat Perkins AC, Britten AJ. Specification and performance of intra-operative gamma probes for sentinel node detection. Nucl Med Commun 1999;20(4):309–15.CrossRefPubMed Perkins AC, Britten AJ. Specification and performance of intra-operative gamma probes for sentinel node detection. Nucl Med Commun 1999;20(4):309–15.CrossRefPubMed
35.
Zurück zum Zitat Tiourina T, Arends B, Huysmans D, Rutten H, Lemaire B, Muller S. Evaluation of surgical gamma probes for radioguided sentinel node localization. Eur J Nucl Med 1998;25(9):1224–31.CrossRefPubMed Tiourina T, Arends B, Huysmans D, Rutten H, Lemaire B, Muller S. Evaluation of surgical gamma probes for radioguided sentinel node localization. Eur J Nucl Med 1998;25(9):1224–31.CrossRefPubMed
36.
Zurück zum Zitat Cherry SR, Sorensen JA, Phelps ME. Physics in nuclear medicine. 3rd ed. Philadelphia: Saunders/Elsevier Science; 2003. ISBN 0-7216-8341-X. Cherry SR, Sorensen JA, Phelps ME. Physics in nuclear medicine. 3rd ed. Philadelphia: Saunders/Elsevier Science; 2003. ISBN 0-7216-8341-X.
37.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA NU 4. Performance measurement of small animal positron emission tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 2008. National Electrical Manufacturers Association. NEMA NU 4. Performance measurement of small animal positron emission tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 2008.
38.
Zurück zum Zitat International Electrotechnical Commission. IEC 61223-1. Evaluation and routine testing in medical imaging departments – Part 1: General aspects. Geneva: International Electrotechnical Commission; 1993. International Electrotechnical Commission. IEC 61223-1. Evaluation and routine testing in medical imaging departments – Part 1: General aspects. Geneva: International Electrotechnical Commission; 1993.
39.
Zurück zum Zitat Bergmann H, Minear G, Raith M, Schaffarich PM. Multiple window spatial registration error of a gamma camera: 133Ba point source as a replacement of the NEMA procedure. BMC Med Phys 2008;8:6. Bergmann H, Minear G, Raith M, Schaffarich PM. Multiple window spatial registration error of a gamma camera: 133Ba point source as a replacement of the NEMA procedure. BMC Med Phys 2008;8:6.
40.
Zurück zum Zitat Kwang K, Lee B, Choe J. SU-FF-I-79: development of the practical guidelines of PET-CT quality control. Med Phys 2009;36:2452.CrossRef Kwang K, Lee B, Choe J. SU-FF-I-79: development of the practical guidelines of PET-CT quality control. Med Phys 2009;36:2452.CrossRef
Metadaten
Titel
Routine quality control recommendations for nuclear medicine instrumentation
verfasst von
Ellinor Busemann Sokole
Anna Płachcínska
Alan Britten
Maria Lyra Georgosopoulou
Wendy Tindale
Rigobert Klett
On behalf of the EANM Physics Committee:
With contribution from the EANM Working Group on Nuclear Medicine Instrumentation Quality Control:
Publikationsdatum
01.03.2010
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 3/2010
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-009-1347-y

Weitere Artikel der Ausgabe 3/2010

European Journal of Nuclear Medicine and Molecular Imaging 3/2010 Zur Ausgabe