Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 7/2015

01.06.2015 | Original Article

Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging

verfasst von: Chad R. R. N. Hunter, Jeremy Hill, M. Cecilia Ziadi, Rob S. B. Beanlands, Robert A. deKemp

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

82Rb is an ultra-short-lived positron emitter used for myocardial blood flow quantification with PET imaging. The aim of this study was to quantify the biodistribution and radiation dosimetry in patients with coronary disease and in healthy normal volunteers.

Methods

A total of 30 subjects, 26 patients with known or suspected coronary artery disease (CAD) and four healthy volunteers were injected with 82Rb chloride at 10 MBq/kg followed by a 10-min dynamic PET scan. Chest scans at rest were acquired in all subjects, as well as one additional biodistribution scan of the head, neck, abdomen, pelvis or thighs. Chest scans under stress were acquired in 25 of the CAD patients. 82Rb time-integrated activity coefficients were determined in 22 source organs using volume of interest analysis, including corrections for partial-volume losses. The mean time-integrated activity coefficients were used to calculate the whole-body effective dose using tissue weighting factors from the International Commission on Radiological Protection (ICRP) Publications 60 and 103.

Results

A total of 283 organ time-integrated activity coefficients were calculated, with a minimum of four values per source organ. The rest and stress mean effective dose was 0.8 mSv/GBq, according to the most recent ICRP definition. Using 10 MBq/kg for 3D PET imaging, the effective dose to a gender-averaged reference person (60 kg female and 73 kg male) is 1.1 mSv for a complete rest and stress perfusion study. For 2D PET using a typical injected activity of 1.1 to 2.2 GBq each for rest and stress, the effective dose for a complete study is 1.8 to 3.5 mSv.

Conclusion

The current effective dose estimate in CAD patients is four times lower than the values reported previously by the ICRP, and about 35 % lower than previous in vivo studies in young healthy subjects.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J. 2013;34:2949–3003.CrossRef Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J. 2013;34:2949–3003.CrossRef
2.
Zurück zum Zitat Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37.CrossRefPubMed Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37.CrossRefPubMed
3.
Zurück zum Zitat Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods. Eur J Nucl Med Mol Imaging. 2014;41:126–35.CrossRefPubMed Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods. Eur J Nucl Med Mol Imaging. 2014;41:126–35.CrossRefPubMed
4.
5.
Zurück zum Zitat Senthamizhchelvan S, Bravo PE, Esaias C, Lodge MA, Merrill J, Hobbs RF, et al. Human biodistribution and radiation dosimetry of 82Rb. J Nucl Med. 2010;51:1592–9.CrossRefPubMedCentralPubMed Senthamizhchelvan S, Bravo PE, Esaias C, Lodge MA, Merrill J, Hobbs RF, et al. Human biodistribution and radiation dosimetry of 82Rb. J Nucl Med. 2010;51:1592–9.CrossRefPubMedCentralPubMed
6.
Zurück zum Zitat Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G. Radiation dosimetry of 82Rb in humans under pharmacologic stress. J Nucl Med. 2011;52:485–91.CrossRefPubMedCentralPubMed Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G. Radiation dosimetry of 82Rb in humans under pharmacologic stress. J Nucl Med. 2011;52:485–91.CrossRefPubMedCentralPubMed
7.
Zurück zum Zitat ICRP Publication 80: Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28:1–126. ICRP Publication 80: Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28:1–126.
8.
Zurück zum Zitat Kearfott KJ. Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130. J Nucl Med. 1982;23:1128–32.PubMed Kearfott KJ. Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130. J Nucl Med. 1982;23:1128–32.PubMed
9.
Zurück zum Zitat Leggett RW, Williams LR. A proposed blood circulation model for Reference Man. Health Phys. 1995;69:187–201.CrossRefPubMed Leggett RW, Williams LR. A proposed blood circulation model for Reference Man. Health Phys. 1995;69:187–201.CrossRefPubMed
10.
Zurück zum Zitat Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–18.CrossRefPubMed Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–18.CrossRefPubMed
11.
Zurück zum Zitat Klein R, Adler A. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007;52:659–73.CrossRefPubMed Klein R, Adler A. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007;52:659–73.CrossRefPubMed
12.
Zurück zum Zitat Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960–7.PubMed Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960–7.PubMed
13.
Zurück zum Zitat Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.CrossRefPubMed Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.CrossRefPubMed
14.
Zurück zum Zitat Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed
15.
Zurück zum Zitat ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:1–332. ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:1–332.
16.
Zurück zum Zitat 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1–3):1–201. 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1–3):1–201.
17.
Zurück zum Zitat Stabin MG. Proposed revision to the radiation dosimetry of 82Rb. Health Phys. 2010;99:811–3.CrossRefPubMed Stabin MG. Proposed revision to the radiation dosimetry of 82Rb. Health Phys. 2010;99:811–3.CrossRefPubMed
18.
Zurück zum Zitat Duan Y, Lockwood J, Wei L, Hunter C, Soueidan K, Bensimon C, et al. Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats. EJNMMI Res. 2014;4:16.CrossRefPubMedCentralPubMed Duan Y, Lockwood J, Wei L, Hunter C, Soueidan K, Bensimon C, et al. Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats. EJNMMI Res. 2014;4:16.CrossRefPubMedCentralPubMed
19.
Zurück zum Zitat ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals. Ann. ICRP. 1987;18(1–4):1–377. ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals. Ann. ICRP. 1987;18(1–4):1–377.
20.
Zurück zum Zitat Spector WS. Handbook of biological data. Phildelphia: Saunders; 1956 Spector WS. Handbook of biological data. Phildelphia: Saunders; 1956
21.
Zurück zum Zitat Ryan JW, Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge, Tennessee, 5–8 November 1985. p. 346–58. Ryan JW, Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge, Tennessee, 5–8 November 1985. p. 346–58.
22.
Zurück zum Zitat Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–97.CrossRefPubMed Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–97.CrossRefPubMed
24.
Zurück zum Zitat Dorbala S, Di Carli MF, Delbeke D, Abbara S, DePuey EG, Dilsizian V, et al. SNMMI/ASNC/SCCT guideline for cardiac SPECT/CT and PET/CT 1.0. J Nucl Med. 2013;54:1485–507.CrossRefPubMed Dorbala S, Di Carli MF, Delbeke D, Abbara S, DePuey EG, Dilsizian V, et al. SNMMI/ASNC/SCCT guideline for cardiac SPECT/CT and PET/CT 1.0. J Nucl Med. 2013;54:1485–507.CrossRefPubMed
Metadaten
Titel
Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging
verfasst von
Chad R. R. N. Hunter
Jeremy Hill
M. Cecilia Ziadi
Rob S. B. Beanlands
Robert A. deKemp
Publikationsdatum
01.06.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 7/2015
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-015-3028-3

Weitere Artikel der Ausgabe 7/2015

European Journal of Nuclear Medicine and Molecular Imaging 7/2015 Zur Ausgabe