Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 2/2018

19.09.2017 | Original Article

Patterns of bone tracer uptake on SPECT-CT in symptomatic and asymptomatic patients with primary total hip arthroplasty

verfasst von: Thierry Schweizer, Filippo-Franco Schiapparelli, Niccolo Rotigliano, Helmut Rasch, Felix Amsler, Michael T. Hirschmann

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The primary purpose of this study was to compare bone tracer uptake (BTU) on SPECT/CT in symptomatic and asymptomatic total hip arthroplasty (THA) and identify a possible relationship between BTU patterns and patient’s symptoms. The secondary purpose was to investigate if the fixation methods (cemented versus uncemented) lead to different BTU patterns.

Methods

A total of 58 THAs, 31 symptomatic (group S) and 27 asymptomatic (group AS), were prospectively collected and retrospectively analyzed. All symptomatic patients underwent standardized detailed history, clinical examination, radiographs and 99mTc-HDP SPECT/CT. BTU in SPECT/CT was quantified in three dimensions and anatomically localized in a scheme of quadrants and levels using a customized previously validated software. T tests were used on both quadrants and levels inside and between groups. A Pearson correlation was performed for BTU within the quadrants. An area under receiver operating characteristic curves was drawn in order to find a BTU value that could differentiate the two groups. Within the groups, patients with cemented and uncemented stems were compared for influences on BTU intensity.

Results

The causes of pain were identified in 61% of the patients. The most common problem was aseptic loosening (n = 12). In group AS, levels 1, 2 and 5 had similar BTUs. BTUs in these levels were significantly higher than in level 3, 4 and 6. In group S, no significant differences were seen in terms of BTU in level 1–5. However, BTU here was significantly higher than at level 6 (p < 0.001). In both groups, level 1, the superior, had a significantly higher BTU than level 2 (group AS p < 0.01, group S p < 0.05). Comparing the BTU of the two groups among levels, significant differences were found for level 4, level 5 and the entire stem areas (p < 0.05). The ROC curve calculated on the whole stem allowed identification of a BTU ratio of 3.1 that separated the 92.6% patients of group AS with BTU < 3.1 from the 54.8% of patients of group S with a BTU ≥ 3.1. With regards to the fixation technique, only the BTU at the level 6 in group S presented a significant difference between cemented and uncemented stems (p < 0.05).

Conclusions

Higher BTU levels significantly correlated with symptoms, but a normal BTU could not exclude a specific pathology after THA. A threshold of BTU in SPECT/CT was identified to distinguish between symptomatic and asymptomatic patients after THA.
Literatur
1.
Zurück zum Zitat Anakwe RE, Jenkins PJ, Moran M. Predicting dissatisfaction after total hip arthroplasty: a study of 850 patients. J Arthroplast. 2011;26:209–13.CrossRef Anakwe RE, Jenkins PJ, Moran M. Predicting dissatisfaction after total hip arthroplasty: a study of 850 patients. J Arthroplast. 2011;26:209–13.CrossRef
2.
Zurück zum Zitat Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57–63.CrossRefPubMed Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57–63.CrossRefPubMed
3.
Zurück zum Zitat Rolfson O, Kärrholm J, Dahlberg LE, Garellick G. Patient-reported outcomes in the Swedish hip Arthroplasty register: results of a nationwide prospective observational study. J Bone Joint Surg Br. 2011;93:867–75.CrossRefPubMed Rolfson O, Kärrholm J, Dahlberg LE, Garellick G. Patient-reported outcomes in the Swedish hip Arthroplasty register: results of a nationwide prospective observational study. J Bone Joint Surg Br. 2011;93:867–75.CrossRefPubMed
4.
Zurück zum Zitat Mancuso CA, Salvati EA, Johanson NA, Peterson MG, Charlson ME. Patients' Expectations and satisfaction with total hip arthroplasty. J Arthroplast. 1997;12:387–96.CrossRef Mancuso CA, Salvati EA, Johanson NA, Peterson MG, Charlson ME. Patients' Expectations and satisfaction with total hip arthroplasty. J Arthroplast. 1997;12:387–96.CrossRef
5.
Zurück zum Zitat Spinarelli A, Patella V, Petrera M, Abate A, Pesce V, Patella S. Heterotopic ossification after total hip arthroplasty: our experience. Musculoskelet Surg. 2011;95:1–5.CrossRefPubMed Spinarelli A, Patella V, Petrera M, Abate A, Pesce V, Patella S. Heterotopic ossification after total hip arthroplasty: our experience. Musculoskelet Surg. 2011;95:1–5.CrossRefPubMed
6.
Zurück zum Zitat Pluot E, Davis ET, Revell M, Davies AM, S.L.J. J. Hip arthroplasty. Part 2: normal and abnormal radiographic findings. Clin Radiol. 2009;64:961–71.CrossRefPubMed Pluot E, Davis ET, Revell M, Davies AM, S.L.J. J. Hip arthroplasty. Part 2: normal and abnormal radiographic findings. Clin Radiol. 2009;64:961–71.CrossRefPubMed
7.
Zurück zum Zitat Vanquickenborne B, Maes A, Nuyts J, Van Acker F, Stuyck J, Mulier M, et al. The value of 18FDG-PET for the detection of infected hip prosthesis. Eur J Nucl Med Mol Imaging. 2003;30:705–15.CrossRefPubMed Vanquickenborne B, Maes A, Nuyts J, Van Acker F, Stuyck J, Mulier M, et al. The value of 18FDG-PET for the detection of infected hip prosthesis. Eur J Nucl Med Mol Imaging. 2003;30:705–15.CrossRefPubMed
8.
Zurück zum Zitat Tam H, Bhaludin B, Rahman F, Weller A, Ejindu V, Parthipun A. SPECT-CT in total hip arthroplasty. Clin Radiol. 2014;69:82–95.CrossRefPubMed Tam H, Bhaludin B, Rahman F, Weller A, Ejindu V, Parthipun A. SPECT-CT in total hip arthroplasty. Clin Radiol. 2014;69:82–95.CrossRefPubMed
9.
Zurück zum Zitat Kaisidis A, Megas P, Apostolopoulos D, Spiridonidis T, Koumoundourou D, Zouboulis P, et al. Diagnose septischer Hüftprothesenlockerung via LeukoScan. Orthopade. 2005;34:462–9.CrossRefPubMed Kaisidis A, Megas P, Apostolopoulos D, Spiridonidis T, Koumoundourou D, Zouboulis P, et al. Diagnose septischer Hüftprothesenlockerung via LeukoScan. Orthopade. 2005;34:462–9.CrossRefPubMed
10.
Zurück zum Zitat Awengen R, Rasch H, Amsler F, Hirschmann MT. Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging. 2016;43:762–72.CrossRefPubMed Awengen R, Rasch H, Amsler F, Hirschmann MT. Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging. 2016;43:762–72.CrossRefPubMed
11.
Zurück zum Zitat Forrer F, Hirschmann MT, Rasch HF. Painful knee prosthesis: is there a role for bone SPECT/CT? Nucl Med Commun. 2014;35:782.CrossRefPubMed Forrer F, Hirschmann MT, Rasch HF. Painful knee prosthesis: is there a role for bone SPECT/CT? Nucl Med Commun. 2014;35:782.CrossRefPubMed
12.
Zurück zum Zitat Hirschmann A, Hirschmann MT. Chronic knee pain: clinical value of MRI versus SPECT/CT. Seminars Muscul Radiol. 2016;20:3–11.CrossRef Hirschmann A, Hirschmann MT. Chronic knee pain: clinical value of MRI versus SPECT/CT. Seminars Muscul Radiol. 2016;20:3–11.CrossRef
13.
Zurück zum Zitat Hirschmann M, Mathis D, Rasch H, Amsler F, Friederich N, Arnold M. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site. Int Orthop. 2013;37:301–9.CrossRefPubMed Hirschmann M, Mathis D, Rasch H, Amsler F, Friederich N, Arnold M. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site. Int Orthop. 2013;37:301–9.CrossRefPubMed
14.
Zurück zum Zitat Hirschmann MT, Adler T, Rasch H, Hügli RW, Friederich NF, Arnold MP. Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol. 2010;2(24). Hirschmann MT, Adler T, Rasch H, Hügli RW, Friederich NF, Arnold MP. Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol. 2010;2(24).
15.
Zurück zum Zitat Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF. Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop. 2011;35:675–80.CrossRefPubMed Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF. Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop. 2011;35:675–80.CrossRefPubMed
16.
Zurück zum Zitat Hirschmann MT, Davda K, Rasch H, Arnold MP, Friederich NF. Clinical value of combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) in sports medicine. Sports Med Arthrosc. 2011;19:174–81.CrossRefPubMed Hirschmann MT, Davda K, Rasch H, Arnold MP, Friederich NF. Clinical value of combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) in sports medicine. Sports Med Arthrosc. 2011;19:174–81.CrossRefPubMed
17.
Zurück zum Zitat Hirschmann MT, Iranpour F, Davda K, Rasch H, Hügli R, Friederich NF. Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. 2010;18:341–5.CrossRefPubMed Hirschmann MT, Iranpour F, Davda K, Rasch H, Hügli R, Friederich NF. Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. 2010;18:341–5.CrossRefPubMed
18.
Zurück zum Zitat Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, et al. A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010;18:939–44.CrossRefPubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, et al. A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010;18:939–44.CrossRefPubMed
19.
Zurück zum Zitat Hirschmann MT, Johann H, Helmut R. SPECT/CT in patients with painful knee arthroplasty - what is the evidence? Skelet Radiol. 2013;42:1201–7.CrossRef Hirschmann MT, Johann H, Helmut R. SPECT/CT in patients with painful knee arthroplasty - what is the evidence? Skelet Radiol. 2013;42:1201–7.CrossRef
20.
Zurück zum Zitat Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty--a new dimension of diagnostics?. BMC Musculoskelet Disord. 2011;12(36). Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty--a new dimension of diagnostics?. BMC Musculoskelet Disord. 2011;12(36).
21.
Zurück zum Zitat Hirschmann MT, Mathis D, Afifi FK, Rasch H, Henckel J, Amsler F, et al. Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information. Knee Surg Sports Traumatol Arthrosc. 2013;21:965–74.CrossRefPubMed Hirschmann MT, Mathis D, Afifi FK, Rasch H, Henckel J, Amsler F, et al. Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information. Knee Surg Sports Traumatol Arthrosc. 2013;21:965–74.CrossRefPubMed
22.
Zurück zum Zitat Hirschmann MT, Schmid R, Dhawan R, Skarvan J, Rasch H, Friederich NF, et al. Combined single photon emission computerized tomography and conventional computerized tomography: clinical value for the shoulder surgeons? Int J Shoulder Surg. 2011;5:72–6.CrossRefPubMedPubMedCentral Hirschmann MT, Schmid R, Dhawan R, Skarvan J, Rasch H, Friederich NF, et al. Combined single photon emission computerized tomography and conventional computerized tomography: clinical value for the shoulder surgeons? Int J Shoulder Surg. 2011;5:72–6.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Hirschmann MT, Schön S, Afifi FK, Amsler F, Rasch H, Friederich NK, et al. Assessment of loading history of compartments in the knee using bone SPECT/CT: a study combining alignment and 99mTc-HDP tracer uptake/distribution patterns. J Orthop Res. 2012;31:268–74.CrossRefPubMed Hirschmann MT, Schön S, Afifi FK, Amsler F, Rasch H, Friederich NK, et al. Assessment of loading history of compartments in the knee using bone SPECT/CT: a study combining alignment and 99mTc-HDP tracer uptake/distribution patterns. J Orthop Res. 2012;31:268–74.CrossRefPubMed
24.
Zurück zum Zitat Hirschmann MT, Wagner CR, Rasch H, Henckel J. Standardized volumetric 3D–analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging. 12(5). Hirschmann MT, Wagner CR, Rasch H, Henckel J. Standardized volumetric 3D–analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging. 12(5).
25.
Zurück zum Zitat Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT. Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 2010;24:621–4.CrossRefPubMed Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT. Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 2010;24:621–4.CrossRefPubMed
26.
Zurück zum Zitat Hirschmann MT, Amsler F, Rasch H. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging. 2015;42:1869–82.CrossRefPubMed Hirschmann MT, Amsler F, Rasch H. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging. 2015;42:1869–82.CrossRefPubMed
27.
Zurück zum Zitat Mathis DT, Rasch H, Hirschmann MT. In vivo bone tunnel remodeling in symptomatic patients after ACL reconstruction: a retrospective comparison of articular and extra-articular fixation. Muscles Ligaments Tendons J. 2015;5:316–24.PubMed Mathis DT, Rasch H, Hirschmann MT. In vivo bone tunnel remodeling in symptomatic patients after ACL reconstruction: a retrospective comparison of articular and extra-articular fixation. Muscles Ligaments Tendons J. 2015;5:316–24.PubMed
28.
Zurück zum Zitat Milos Dordevic M, Hirschmann MT, Rechsteiner J, Falkowski A, Testa E, Hirschmann A. Do Chondral lesions of the knee correlate with bone tracer uptake by using SPECT/CT? Radiology. 2016;278:223–31.CrossRefPubMed Milos Dordevic M, Hirschmann MT, Rechsteiner J, Falkowski A, Testa E, Hirschmann A. Do Chondral lesions of the knee correlate with bone tracer uptake by using SPECT/CT? Radiology. 2016;278:223–31.CrossRefPubMed
29.
Zurück zum Zitat Mucha A, Dordevic M, Hirschmann A, Rasch H, Amsler F, Arnold MP, et al. Effect of high tibial osteotomy on joint loading in symptomatic patients with varus aligned knees: a study using SPECT/CT. Knee Surg Sports Traumatol Arthrosc. 2015;23:2315–23.CrossRefPubMed Mucha A, Dordevic M, Hirschmann A, Rasch H, Amsler F, Arnold MP, et al. Effect of high tibial osteotomy on joint loading in symptomatic patients with varus aligned knees: a study using SPECT/CT. Knee Surg Sports Traumatol Arthrosc. 2015;23:2315–23.CrossRefPubMed
30.
Zurück zum Zitat Mucha A, Dordevic M, Testa EA, Rasch H, Hirschmann MT. Assessment of the loading history of patients after high tibial osteotomy using SPECT/CT-a new diagnostic tool and algorithm. J Orthop Surg Res. 2013;8(46). Mucha A, Dordevic M, Testa EA, Rasch H, Hirschmann MT. Assessment of the loading history of patients after high tibial osteotomy using SPECT/CT-a new diagnostic tool and algorithm. J Orthop Surg Res. 2013;8(46).
31.
Zurück zum Zitat Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT. 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol. 2013;42:1215–23.CrossRef Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT. 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol. 2013;42:1215–23.CrossRef
32.
Zurück zum Zitat Rieger B, Friederich NF, Rasch H, Hirschmann MT. Non-dislocated osteoporotic insufficiency fracture of the medial femoral neck. SPECT/CT makes the diagnostic difference. Unfallchirurgie. 2014;117:369–73.CrossRef Rieger B, Friederich NF, Rasch H, Hirschmann MT. Non-dislocated osteoporotic insufficiency fracture of the medial femoral neck. SPECT/CT makes the diagnostic difference. Unfallchirurgie. 2014;117:369–73.CrossRef
33.
Zurück zum Zitat Schön SN, Afifi FK, Rasch H, Amsler F, Friederich NF, Arnold MP, et al. Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT. Knee Surg Sports Traumatol Arthrosc. 2014;22:3039–46.CrossRefPubMed Schön SN, Afifi FK, Rasch H, Amsler F, Friederich NF, Arnold MP, et al. Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT. Knee Surg Sports Traumatol Arthrosc. 2014;22:3039–46.CrossRefPubMed
34.
Zurück zum Zitat Suter B, Testa E, Stämpfli P, Konala P, Rasch H, Friederich NF et al. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty-a combined analysis of tracer uptake distribution and component position. BMC Med Imaging. 2015;15(11). Suter B, Testa E, Stämpfli P, Konala P, Rasch H, Friederich NF et al. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty-a combined analysis of tracer uptake distribution and component position. BMC Med Imaging. 2015;15(11).
35.
Zurück zum Zitat Testa EA, Haeni DL, Behrens G, Hirschmann MT. Unexplained proximal tibiofibular joint pain after high tibial osteotomy. Indian J Orthop. 2014;48:335–8.CrossRefPubMedPubMedCentral Testa EA, Haeni DL, Behrens G, Hirschmann MT. Unexplained proximal tibiofibular joint pain after high tibial osteotomy. Indian J Orthop. 2014;48:335–8.CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Arıcan P, Okudan TB, Şefizade R, Naldöken S, Baştuğ A, Özkurt B. The role of bone SPECT/CT in the evaluation of painful joint prostheses. Nucl Med Commun. 2015;36:931–40.CrossRefPubMed Arıcan P, Okudan TB, Şefizade R, Naldöken S, Baştuğ A, Özkurt B. The role of bone SPECT/CT in the evaluation of painful joint prostheses. Nucl Med Commun. 2015;36:931–40.CrossRefPubMed
37.
Zurück zum Zitat Chew CG, Lewis P, Middleton F, Van den Wijngaard R, Deshaies A. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses. Ann Nucl Med. 2010;24:735–43.CrossRefPubMed Chew CG, Lewis P, Middleton F, Van den Wijngaard R, Deshaies A. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses. Ann Nucl Med. 2010;24:735–43.CrossRefPubMed
38.
Zurück zum Zitat Dobrindt O, Amthauer H, Krueger A, Ruf J, Wissel H, Grosser OS et al. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty. BMC Med Imaging. 2015;15(18). Dobrindt O, Amthauer H, Krueger A, Ruf J, Wissel H, Grosser OS et al. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty. BMC Med Imaging. 2015;15(18).
39.
Zurück zum Zitat Yue B, Tang T. The use of nuclear imaging for the diagnosis of periprosthetic infection after knee and hip arthroplasties. Nucl Med Commun. 2015;36:305–11.CrossRefPubMed Yue B, Tang T. The use of nuclear imaging for the diagnosis of periprosthetic infection after knee and hip arthroplasties. Nucl Med Commun. 2015;36:305–11.CrossRefPubMed
41.
Zurück zum Zitat Synder M, Krajewski K, Sibinski M, Drobniewski M. Periprosthetic bone remodeling around short stem. Orthopedics. 2015;38(3 Suppl):S40–5.CrossRefPubMed Synder M, Krajewski K, Sibinski M, Drobniewski M. Periprosthetic bone remodeling around short stem. Orthopedics. 2015;38(3 Suppl):S40–5.CrossRefPubMed
42.
Zurück zum Zitat Zeh A, Pankow F, Röllinhoff M, Delank S, Wohlrab D. A prospective dual-energy X-ray absorptiometry study of bone remodeling after implantation of the Nanos short-stemmed prosthesis. Acta Orthop Belg. 2013;79:174–80.PubMed Zeh A, Pankow F, Röllinhoff M, Delank S, Wohlrab D. A prospective dual-energy X-ray absorptiometry study of bone remodeling after implantation of the Nanos short-stemmed prosthesis. Acta Orthop Belg. 2013;79:174–80.PubMed
Metadaten
Titel
Patterns of bone tracer uptake on SPECT-CT in symptomatic and asymptomatic patients with primary total hip arthroplasty
verfasst von
Thierry Schweizer
Filippo-Franco Schiapparelli
Niccolo Rotigliano
Helmut Rasch
Felix Amsler
Michael T. Hirschmann
Publikationsdatum
19.09.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 2/2018
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-017-3827-9

Weitere Artikel der Ausgabe 2/2018

European Journal of Nuclear Medicine and Molecular Imaging 2/2018 Zur Ausgabe